{"title":"甲藻培养物中 DMSP 测量方法的比较","authors":"Amandine M. N. Caruana,&nbsp;Eva Bucciarelli,&nbsp;Céline Deleporte,&nbsp;Emilie Le Floc'h,&nbsp;Fabienne Hervé,&nbsp;Manon Le Goff","doi":"10.1002/lom3.10618","DOIUrl":null,"url":null,"abstract":"<p>A comparison of three analytical methods (the indirect GC-FPD and MIMS, and direct LC-MS/MS) for dimethylsulfoniopropionate (DMSP) measurements was conducted to assess their accuracy and reliability. The three methods showed a linear response but are distinguished by their linearity range, the largest being for MIMS. All three methods showed good precision on <i>Alexandrium minutum</i> samples (2–12%). The variability between the three methods when comparing analyses of <i>A. minutum</i> replicates was 11%, with the DMSP measurements by LC-MS/MS being the highest. This result also confirms that indirect DMSP measurement after hydrolysis for GC or MIMS methods does not lead to an overestimation of DMSP values in <i>A. minutum</i>. A special focus was made on the more recent LC-MS/MS method including further assays in sample preparation and storage from cultures of the dinoflagellate <i>A. minutum</i>. Dinoflagellate cells should be harvested by gentle filtration (&lt; 5 cm Hg) or slow centrifugation (500 × <i>g</i>) to retrieve the largest DMSP pool. For the LC-MS/MS method, MeOH used for cell extraction should be added prior to freezing (to prevent DMSP degradation). Samples will then be stable in frozen storage for at least 2 months. Finally, direct and indirect methods are complementary for identifying the exact DMSP fraction among dimethylsulfide-producing compounds that compose total and particulate DMSP pools issued from newly screened organisms or environmental samples.</p>","PeriodicalId":18145,"journal":{"name":"Limnology and Oceanography: Methods","volume":"22 6","pages":"437-449"},"PeriodicalIF":2.1000,"publicationDate":"2024-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/lom3.10618","citationCount":"0","resultStr":"{\"title\":\"Comparison of methods for DMSP measurements in dinoflagellate cultures\",\"authors\":\"Amandine M. N. Caruana,&nbsp;Eva Bucciarelli,&nbsp;Céline Deleporte,&nbsp;Emilie Le Floc'h,&nbsp;Fabienne Hervé,&nbsp;Manon Le Goff\",\"doi\":\"10.1002/lom3.10618\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A comparison of three analytical methods (the indirect GC-FPD and MIMS, and direct LC-MS/MS) for dimethylsulfoniopropionate (DMSP) measurements was conducted to assess their accuracy and reliability. The three methods showed a linear response but are distinguished by their linearity range, the largest being for MIMS. All three methods showed good precision on <i>Alexandrium minutum</i> samples (2–12%). The variability between the three methods when comparing analyses of <i>A. minutum</i> replicates was 11%, with the DMSP measurements by LC-MS/MS being the highest. This result also confirms that indirect DMSP measurement after hydrolysis for GC or MIMS methods does not lead to an overestimation of DMSP values in <i>A. minutum</i>. A special focus was made on the more recent LC-MS/MS method including further assays in sample preparation and storage from cultures of the dinoflagellate <i>A. minutum</i>. Dinoflagellate cells should be harvested by gentle filtration (&lt; 5 cm Hg) or slow centrifugation (500 × <i>g</i>) to retrieve the largest DMSP pool. For the LC-MS/MS method, MeOH used for cell extraction should be added prior to freezing (to prevent DMSP degradation). Samples will then be stable in frozen storage for at least 2 months. Finally, direct and indirect methods are complementary for identifying the exact DMSP fraction among dimethylsulfide-producing compounds that compose total and particulate DMSP pools issued from newly screened organisms or environmental samples.</p>\",\"PeriodicalId\":18145,\"journal\":{\"name\":\"Limnology and Oceanography: Methods\",\"volume\":\"22 6\",\"pages\":\"437-449\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/lom3.10618\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Limnology and Oceanography: Methods\",\"FirstCategoryId\":\"89\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/lom3.10618\",\"RegionNum\":3,\"RegionCategory\":\"地球科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"LIMNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Limnology and Oceanography: Methods","FirstCategoryId":"89","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/lom3.10618","RegionNum":3,"RegionCategory":"地球科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"LIMNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

对测量二甲基硫代丙酸酯(DMSP)的三种分析方法(间接 GC-FPD 和 MIMS,以及直接 LC-MS/MS)进行了比较,以评估其准确性和可靠性。这三种方法都显示出线性响应,但线性范围不同,MIMS 的线性范围最大。这三种方法对小亚历山大藻样本都显示出良好的精确度(2%-12%)。在比较 A. minutum 重复样本的分析结果时,三种方法之间的变异率为 11%,其中以 LC-MS/MS 的 DMSP 测量结果最高。这一结果还证实,采用气相色谱或 MIMS 方法对水解后的 DMSP 进行间接测量不会导致过高估计 A. minutum 中的 DMSP 值。我们特别关注了最新的 LC-MS/MS 方法,其中包括对小型甲藻培养物的样品制备和储存进行进一步检测。应通过轻柔过滤(< 5 cm Hg)或缓慢离心(500 × g)收获甲藻细胞,以获取最大的 DMSP 池。对于 LC-MS/MS 方法,用于提取细胞的 MeOH 应在冷冻前加入(以防止 DMSP 降解)。这样,样本在冷冻储存中至少可以稳定 2 个月。最后,直接法和间接法是互补的,可用于确定从新筛选的生物或环境样本中获得的总DMSP池和微粒DMSP池中二甲基硫化物产生化合物的确切DMSP部分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Comparison of methods for DMSP measurements in dinoflagellate cultures

Comparison of methods for DMSP measurements in dinoflagellate cultures

A comparison of three analytical methods (the indirect GC-FPD and MIMS, and direct LC-MS/MS) for dimethylsulfoniopropionate (DMSP) measurements was conducted to assess their accuracy and reliability. The three methods showed a linear response but are distinguished by their linearity range, the largest being for MIMS. All three methods showed good precision on Alexandrium minutum samples (2–12%). The variability between the three methods when comparing analyses of A. minutum replicates was 11%, with the DMSP measurements by LC-MS/MS being the highest. This result also confirms that indirect DMSP measurement after hydrolysis for GC or MIMS methods does not lead to an overestimation of DMSP values in A. minutum. A special focus was made on the more recent LC-MS/MS method including further assays in sample preparation and storage from cultures of the dinoflagellate A. minutum. Dinoflagellate cells should be harvested by gentle filtration (< 5 cm Hg) or slow centrifugation (500 × g) to retrieve the largest DMSP pool. For the LC-MS/MS method, MeOH used for cell extraction should be added prior to freezing (to prevent DMSP degradation). Samples will then be stable in frozen storage for at least 2 months. Finally, direct and indirect methods are complementary for identifying the exact DMSP fraction among dimethylsulfide-producing compounds that compose total and particulate DMSP pools issued from newly screened organisms or environmental samples.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.80
自引率
3.70%
发文量
56
审稿时长
3 months
期刊介绍: Limnology and Oceanography: Methods (ISSN 1541-5856) is a companion to ASLO''s top-rated journal Limnology and Oceanography, and articles are held to the same high standards. In order to provide the most rapid publication consistent with high standards, Limnology and Oceanography: Methods appears in electronic format only, and the entire submission and review system is online. Articles are posted as soon as they are accepted and formatted for publication. Limnology and Oceanography: Methods will consider manuscripts whose primary focus is methodological, and that deal with problems in the aquatic sciences. Manuscripts may present new measurement equipment, techniques for analyzing observations or samples, methods for understanding and interpreting information, analyses of metadata to examine the effectiveness of approaches, invited and contributed reviews and syntheses, and techniques for communicating and teaching in the aquatic sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信