利用等离子体芯片实现高空间分辨率表面等离子体共振成像。

Yasunori Nawa, Keiko Tawa
{"title":"利用等离子体芯片实现高空间分辨率表面等离子体共振成像。","authors":"Yasunori Nawa, Keiko Tawa","doi":"10.1063/5.0201230","DOIUrl":null,"url":null,"abstract":"The surface plasmon resonance (SPR) technique has been widely applied to biosensing technologies for the rapid quantification of biomolecules without enzyme and fluorescent labeling. However, the conventional prism-coupling SPR method generally has a detection area of a few mm2, and the large contribution of the background signal forms a barrier to highly sensitive detection. Based on a highly spatially resolved SPR method, the present study constructed a scanning GC-SPR imaging instrument using an objective lens with a high numerical aperture and a plasmonic chip that could be used for grating-coupled SPR. Focusing light on the diffraction limit can suppress background signals and improve detection sensitivity. SPR imaging can also be performed by scanning a focal spot. Using this method, the refractive index of a mixture of water and dimethyl sulfoxide was measured with a detection accuracy of 2.43 × 10-3 RIU. Polydopamine films prepared with a thickness of <5 nm were also measured, and each film thickness was evaluated with high sensitivity from the effective refractive index detected in a small area of <1 µm2.","PeriodicalId":501648,"journal":{"name":"The Journal of Chemical Physics","volume":"87 6","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"High spatial resolution surface plasmon resonance imaging using a plasmonic chip.\",\"authors\":\"Yasunori Nawa, Keiko Tawa\",\"doi\":\"10.1063/5.0201230\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The surface plasmon resonance (SPR) technique has been widely applied to biosensing technologies for the rapid quantification of biomolecules without enzyme and fluorescent labeling. However, the conventional prism-coupling SPR method generally has a detection area of a few mm2, and the large contribution of the background signal forms a barrier to highly sensitive detection. Based on a highly spatially resolved SPR method, the present study constructed a scanning GC-SPR imaging instrument using an objective lens with a high numerical aperture and a plasmonic chip that could be used for grating-coupled SPR. Focusing light on the diffraction limit can suppress background signals and improve detection sensitivity. SPR imaging can also be performed by scanning a focal spot. Using this method, the refractive index of a mixture of water and dimethyl sulfoxide was measured with a detection accuracy of 2.43 × 10-3 RIU. Polydopamine films prepared with a thickness of <5 nm were also measured, and each film thickness was evaluated with high sensitivity from the effective refractive index detected in a small area of <1 µm2.\",\"PeriodicalId\":501648,\"journal\":{\"name\":\"The Journal of Chemical Physics\",\"volume\":\"87 6\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of Chemical Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0201230\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Chemical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1063/5.0201230","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

表面等离子体共振(SPR)技术已被广泛应用于生物传感技术,无需酶和荧光标记即可快速定量检测生物大分子。然而,传统的棱镜耦合 SPR 方法的检测面积一般只有几平方毫米,背景信号的贡献较大,阻碍了高灵敏度检测的实现。本研究在高空间分辨 SPR 方法的基础上,利用高数值孔径物镜和可用于光栅耦合 SPR 的等离子体芯片,构建了一种扫描 GC-SPR 成像仪器。将光聚焦在衍射极限上可以抑制背景信号,提高检测灵敏度。SPR 成像还可以通过扫描焦点来实现。使用这种方法测量了水和二甲亚砜混合物的折射率,检测精度为 2.43 × 10-3 RIU。此外,还测量了厚度小于 5 纳米的多多巴胺薄膜,并根据在小于 1 微米2 的小区域内检测到的有效折射率对每种薄膜厚度进行了高灵敏度评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
High spatial resolution surface plasmon resonance imaging using a plasmonic chip.
The surface plasmon resonance (SPR) technique has been widely applied to biosensing technologies for the rapid quantification of biomolecules without enzyme and fluorescent labeling. However, the conventional prism-coupling SPR method generally has a detection area of a few mm2, and the large contribution of the background signal forms a barrier to highly sensitive detection. Based on a highly spatially resolved SPR method, the present study constructed a scanning GC-SPR imaging instrument using an objective lens with a high numerical aperture and a plasmonic chip that could be used for grating-coupled SPR. Focusing light on the diffraction limit can suppress background signals and improve detection sensitivity. SPR imaging can also be performed by scanning a focal spot. Using this method, the refractive index of a mixture of water and dimethyl sulfoxide was measured with a detection accuracy of 2.43 × 10-3 RIU. Polydopamine films prepared with a thickness of <5 nm were also measured, and each film thickness was evaluated with high sensitivity from the effective refractive index detected in a small area of <1 µm2.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信