{"title":"评估 CBCT 衍生模型的免费分割工具:具有成本效益的解决方案。","authors":"Noha M Elkersh, Hams H Abdelrahman, Mohamed G Hassan","doi":"10.1111/ocr.12799","DOIUrl":null,"url":null,"abstract":"OBJECTIVES\nThis study evaluated the segmentation accuracy and reliability of free software packages and compared them with commercial alternatives.\n\n\nMATERIAL AND METHODS\nA total of 36 stone models were scanned using a desktop scanner and then imaged by cone beam computed tomography (CBCT). The CBCT volumes were segmented using 2 free software packages (3D Slicer and Blue Sky Plan) and 2 commercial software packages (Mimics and OnDemand3D). Stereolithography (STL) files generated by the desktop scanner were used as the control group (reference models). The accuracy of segmentation was evaluated by (1) comparing 6 linear measurements taken from each STL model generated by the 4 software packages with that obtained by the scanner, and (2) deviation analysis of each STL model generated by the 4 software packages with that obtained by the scanner. Absolute error and percentage error, repeated measures anova and Friedman test followed by post hoc analysis, intraclass correlation coefficient (ICC), and Pearson's r were used to evaluate the accuracy of the tested software packages.\n\n\nRESULTS\nThere was no statistically significant difference in all intra-arch measurements obtained using the four software packages. Measurements obtained using the free software packages and the scanner showed excellent positive correlation, ranging from 0.825 to 0.988, confirming equivalence with commercial software packages.\n\n\nCONCLUSION\nWithin the settings of the current study, accurate and time-saving segmentations with high positive correlation could be performed using the tested free segmentation software packages (3D Slicer and Blue Sky Plan). Nevertheless, further evaluation is necessary to gage their accuracy using different CBCT modalities.","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-04-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluating free segmentation tools for CBCT-derived models: Cost-effective solutions.\",\"authors\":\"Noha M Elkersh, Hams H Abdelrahman, Mohamed G Hassan\",\"doi\":\"10.1111/ocr.12799\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"OBJECTIVES\\nThis study evaluated the segmentation accuracy and reliability of free software packages and compared them with commercial alternatives.\\n\\n\\nMATERIAL AND METHODS\\nA total of 36 stone models were scanned using a desktop scanner and then imaged by cone beam computed tomography (CBCT). The CBCT volumes were segmented using 2 free software packages (3D Slicer and Blue Sky Plan) and 2 commercial software packages (Mimics and OnDemand3D). Stereolithography (STL) files generated by the desktop scanner were used as the control group (reference models). The accuracy of segmentation was evaluated by (1) comparing 6 linear measurements taken from each STL model generated by the 4 software packages with that obtained by the scanner, and (2) deviation analysis of each STL model generated by the 4 software packages with that obtained by the scanner. Absolute error and percentage error, repeated measures anova and Friedman test followed by post hoc analysis, intraclass correlation coefficient (ICC), and Pearson's r were used to evaluate the accuracy of the tested software packages.\\n\\n\\nRESULTS\\nThere was no statistically significant difference in all intra-arch measurements obtained using the four software packages. Measurements obtained using the free software packages and the scanner showed excellent positive correlation, ranging from 0.825 to 0.988, confirming equivalence with commercial software packages.\\n\\n\\nCONCLUSION\\nWithin the settings of the current study, accurate and time-saving segmentations with high positive correlation could be performed using the tested free segmentation software packages (3D Slicer and Blue Sky Plan). Nevertheless, further evaluation is necessary to gage their accuracy using different CBCT modalities.\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-04-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/ocr.12799\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/ocr.12799","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

本研究评估了免费软件包的分割准确性和可靠性,并将其与商业软件进行了比较。材料和方法使用台式扫描仪扫描了总共 36 个结石模型,然后用锥束计算机断层扫描(CBCT)成像。使用两个免费软件包(3D Slicer 和 Blue Sky Plan)和两个商业软件包(Mimics 和 OnDemand3D)对 CBCT 图像进行分割。桌面扫描仪生成的立体光刻(STL)文件被用作对照组(参考模型)。评估分割准确性的方法是:(1) 将 4 个软件包生成的每个 STL 模型的 6 次线性测量结果与扫描仪获得的结果进行比较;(2) 对 4 个软件包生成的每个 STL 模型与扫描仪获得的结果进行偏差分析。使用绝对误差和百分比误差、重复测量 anova 和 Friedman 检验(然后进行事后分析)、类内相关系数 (ICC) 和 Pearson's r 来评估测试软件包的准确性。使用免费软件包和扫描仪获得的测量结果显示出极好的正相关性,范围在 0.825 到 0.988 之间,证实了与商业软件包的等效性。结论在当前研究的设置下,使用测试的免费分割软件包(3D Slicer 和 Blue Sky Plan)可以进行准确、省时且正相关性高的分割。尽管如此,仍有必要进一步评估它们在不同 CBCT 模式下的准确性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluating free segmentation tools for CBCT-derived models: Cost-effective solutions.
OBJECTIVES This study evaluated the segmentation accuracy and reliability of free software packages and compared them with commercial alternatives. MATERIAL AND METHODS A total of 36 stone models were scanned using a desktop scanner and then imaged by cone beam computed tomography (CBCT). The CBCT volumes were segmented using 2 free software packages (3D Slicer and Blue Sky Plan) and 2 commercial software packages (Mimics and OnDemand3D). Stereolithography (STL) files generated by the desktop scanner were used as the control group (reference models). The accuracy of segmentation was evaluated by (1) comparing 6 linear measurements taken from each STL model generated by the 4 software packages with that obtained by the scanner, and (2) deviation analysis of each STL model generated by the 4 software packages with that obtained by the scanner. Absolute error and percentage error, repeated measures anova and Friedman test followed by post hoc analysis, intraclass correlation coefficient (ICC), and Pearson's r were used to evaluate the accuracy of the tested software packages. RESULTS There was no statistically significant difference in all intra-arch measurements obtained using the four software packages. Measurements obtained using the free software packages and the scanner showed excellent positive correlation, ranging from 0.825 to 0.988, confirming equivalence with commercial software packages. CONCLUSION Within the settings of the current study, accurate and time-saving segmentations with high positive correlation could be performed using the tested free segmentation software packages (3D Slicer and Blue Sky Plan). Nevertheless, further evaluation is necessary to gage their accuracy using different CBCT modalities.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信