{"title":"跑步机行走时颈椎-吸气肌肌电图与摄氧量的相关性 颈椎-吸气肌肌电图与摄氧量的相关性","authors":"Kenta Kawamura , Kazumichi Ae , Rinri Uematsu , Kazuto Yamaguchi , Kazuhide Tomita","doi":"10.1016/j.resp.2024.104266","DOIUrl":null,"url":null,"abstract":"<div><p>For measurements of exercise intensity, an individual's oxygen uptake (V̇O<sub>2</sub>) is measured with an exhaled gas analyzer that involves a mask, but exercise coaching would benefit if an individual's V̇O<sub>2</sub> could be estimated with more easily obtained predictors. We investigated the predictability of V̇O<sub>2</sub> by electromyography (EMG) of the neck inspiratory muscles. We analyzed the EMG results of the sternocleidomastoid (EMGst) and scalene (EMGsc) muscles of 14 healthy adults who performed a treadmill exercise load test. Their V̇O<sub>2</sub>, inspiratory flow rate, and heart rate were simultaneously recorded during the exercise. The exercise load test was performed twice at a ≥2-day interval. The first visit was an incremental exercise test, and the second was a repeated two-load exercise test at levels below and above the participant's ventilatory threshold (VT) as determined in the first test. We observed that the integrated EMG values for each exercise load showed partially significant positive correlations with the EMGst and EMGsc. However, the cervical inspiratory muscle EMGs did not show as high a correlation as the minute ventilation. These results indicate that (<em>i</em>) EMG of the cervical inspiratory muscles could be used to estimate V̇O<sub>2</sub>, but (<em>ii</em>) these EMG parameters alone should be considered insufficient for estimating V̇O<sub>2</sub>.</p></div>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Correlation of cervical-inspiratory-muscle electromyography and oxygen uptake during treadmill walking correlation of cervical-inspiratory-muscle electromyography and oxygen uptake\",\"authors\":\"Kenta Kawamura , Kazumichi Ae , Rinri Uematsu , Kazuto Yamaguchi , Kazuhide Tomita\",\"doi\":\"10.1016/j.resp.2024.104266\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>For measurements of exercise intensity, an individual's oxygen uptake (V̇O<sub>2</sub>) is measured with an exhaled gas analyzer that involves a mask, but exercise coaching would benefit if an individual's V̇O<sub>2</sub> could be estimated with more easily obtained predictors. We investigated the predictability of V̇O<sub>2</sub> by electromyography (EMG) of the neck inspiratory muscles. We analyzed the EMG results of the sternocleidomastoid (EMGst) and scalene (EMGsc) muscles of 14 healthy adults who performed a treadmill exercise load test. Their V̇O<sub>2</sub>, inspiratory flow rate, and heart rate were simultaneously recorded during the exercise. The exercise load test was performed twice at a ≥2-day interval. The first visit was an incremental exercise test, and the second was a repeated two-load exercise test at levels below and above the participant's ventilatory threshold (VT) as determined in the first test. We observed that the integrated EMG values for each exercise load showed partially significant positive correlations with the EMGst and EMGsc. However, the cervical inspiratory muscle EMGs did not show as high a correlation as the minute ventilation. These results indicate that (<em>i</em>) EMG of the cervical inspiratory muscles could be used to estimate V̇O<sub>2</sub>, but (<em>ii</em>) these EMG parameters alone should be considered insufficient for estimating V̇O<sub>2</sub>.</p></div>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-04-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1569904824000594\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1569904824000594","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Correlation of cervical-inspiratory-muscle electromyography and oxygen uptake during treadmill walking correlation of cervical-inspiratory-muscle electromyography and oxygen uptake
For measurements of exercise intensity, an individual's oxygen uptake (V̇O2) is measured with an exhaled gas analyzer that involves a mask, but exercise coaching would benefit if an individual's V̇O2 could be estimated with more easily obtained predictors. We investigated the predictability of V̇O2 by electromyography (EMG) of the neck inspiratory muscles. We analyzed the EMG results of the sternocleidomastoid (EMGst) and scalene (EMGsc) muscles of 14 healthy adults who performed a treadmill exercise load test. Their V̇O2, inspiratory flow rate, and heart rate were simultaneously recorded during the exercise. The exercise load test was performed twice at a ≥2-day interval. The first visit was an incremental exercise test, and the second was a repeated two-load exercise test at levels below and above the participant's ventilatory threshold (VT) as determined in the first test. We observed that the integrated EMG values for each exercise load showed partially significant positive correlations with the EMGst and EMGsc. However, the cervical inspiratory muscle EMGs did not show as high a correlation as the minute ventilation. These results indicate that (i) EMG of the cervical inspiratory muscles could be used to estimate V̇O2, but (ii) these EMG parameters alone should be considered insufficient for estimating V̇O2.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.