评估两种基于 RT-PCR 的床旁检验的分析和临床性能:Cepheid Xpert® Xpress CoV-2/Flu/RSV plus 和 SD BioSensor STANDARD™ M10 Flu/RSV/SARS-CoV-2

IF 4 3区 医学 Q2 VIROLOGY
Christel Barker Jensen , Uffe Vest Schneider , Tina Vasehus Madsen , Xiaohui Chen Nielsen , Chih Man German Ma , Jette Krogh Severinsen , Anne Mette Hoegh , Amanda Bolt Botnen , Ramona Trebbien , Jan Gorm Lisby
{"title":"评估两种基于 RT-PCR 的床旁检验的分析和临床性能:Cepheid Xpert® Xpress CoV-2/Flu/RSV plus 和 SD BioSensor STANDARD™ M10 Flu/RSV/SARS-CoV-2","authors":"Christel Barker Jensen ,&nbsp;Uffe Vest Schneider ,&nbsp;Tina Vasehus Madsen ,&nbsp;Xiaohui Chen Nielsen ,&nbsp;Chih Man German Ma ,&nbsp;Jette Krogh Severinsen ,&nbsp;Anne Mette Hoegh ,&nbsp;Amanda Bolt Botnen ,&nbsp;Ramona Trebbien ,&nbsp;Jan Gorm Lisby","doi":"10.1016/j.jcv.2024.105674","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Rapid and accurate detection of viral respiratory infections is important for infection control measures. This study compares the analytical and clinical performance of the Xpert® Xpress CoV-2/Flu/RSV <em>plus</em> test (“Xpert”, Cepheid) and the STANDARD™ M10 Flu/RSV/SARS-CoV-2 test (“M10”, SD Biosensor). Both tests are quadruplex RT-PCR assays for rapid diagnosis of SARS-CoV-2, influenza A/B and RSV.</p></div><div><h3>Study design</h3><p>Analytical sensitivities were determined by limit of detection for SARS-CoV-2, influenza A, influenza B and RSV, respectively. Additionally, the clinical performance of the Xpert and the M10 tests was evaluated against standard-of-care RT-PCR by testing of 492 clinical specimens.</p></div><div><h3>Results</h3><p>The analytical sensitivities for Xpert versus M10 test was 10, 50, 50 and 300 versus 300, 200, 800 and 1500 copies/mL for SARS-CoV-2, influenza A, influenza B and RSV, respectively. Clinical sensitivity for the Xpert test was superior across all four pathogens compared to the M10 test. Xpert showed clinical sensitivity of 100 % in all Ct-ranges for all four pathogens whereas M10 showed clinical sensitivity of 100 % in the 25–30 Ct-range, 84–100 % in the 30–35 Ct-range and 47–67 % in the &gt;35 Ct-range across the four pathogens. Translating into real-life clinical sensitivity, the Xpert would detect 100 % of all four pathogens, whereas M10 would detect 92.1, 92.4, 84.8 and 94.7 % for SARS-CoV-2, influenza A, influenza B and RSV.</p></div><div><h3>Conclusion</h3><p>This study demonstrates improved analytical and clinical performance of Xpert Xpress CoV-2/Flu/RSV <em>plus</em> compared to STANDARD M10 Flu/RSV/SARS-CoV-2, which is important for ensuring accuracy of diagnosis at all stages of a respiratory infection.</p></div>","PeriodicalId":15517,"journal":{"name":"Journal of Clinical Virology","volume":null,"pages":null},"PeriodicalIF":4.0000,"publicationDate":"2024-04-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1386653224000362/pdfft?md5=7458aa65c3c562d9f5fef2f7548a65a6&pid=1-s2.0-S1386653224000362-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the analytical and clinical performance of two RT-PCR based point-of-care tests; Cepheid Xpert® Xpress CoV-2/Flu/RSV plus and SD BioSensor STANDARD™ M10 Flu/RSV/SARS-CoV-2\",\"authors\":\"Christel Barker Jensen ,&nbsp;Uffe Vest Schneider ,&nbsp;Tina Vasehus Madsen ,&nbsp;Xiaohui Chen Nielsen ,&nbsp;Chih Man German Ma ,&nbsp;Jette Krogh Severinsen ,&nbsp;Anne Mette Hoegh ,&nbsp;Amanda Bolt Botnen ,&nbsp;Ramona Trebbien ,&nbsp;Jan Gorm Lisby\",\"doi\":\"10.1016/j.jcv.2024.105674\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Rapid and accurate detection of viral respiratory infections is important for infection control measures. This study compares the analytical and clinical performance of the Xpert® Xpress CoV-2/Flu/RSV <em>plus</em> test (“Xpert”, Cepheid) and the STANDARD™ M10 Flu/RSV/SARS-CoV-2 test (“M10”, SD Biosensor). Both tests are quadruplex RT-PCR assays for rapid diagnosis of SARS-CoV-2, influenza A/B and RSV.</p></div><div><h3>Study design</h3><p>Analytical sensitivities were determined by limit of detection for SARS-CoV-2, influenza A, influenza B and RSV, respectively. Additionally, the clinical performance of the Xpert and the M10 tests was evaluated against standard-of-care RT-PCR by testing of 492 clinical specimens.</p></div><div><h3>Results</h3><p>The analytical sensitivities for Xpert versus M10 test was 10, 50, 50 and 300 versus 300, 200, 800 and 1500 copies/mL for SARS-CoV-2, influenza A, influenza B and RSV, respectively. Clinical sensitivity for the Xpert test was superior across all four pathogens compared to the M10 test. Xpert showed clinical sensitivity of 100 % in all Ct-ranges for all four pathogens whereas M10 showed clinical sensitivity of 100 % in the 25–30 Ct-range, 84–100 % in the 30–35 Ct-range and 47–67 % in the &gt;35 Ct-range across the four pathogens. Translating into real-life clinical sensitivity, the Xpert would detect 100 % of all four pathogens, whereas M10 would detect 92.1, 92.4, 84.8 and 94.7 % for SARS-CoV-2, influenza A, influenza B and RSV.</p></div><div><h3>Conclusion</h3><p>This study demonstrates improved analytical and clinical performance of Xpert Xpress CoV-2/Flu/RSV <em>plus</em> compared to STANDARD M10 Flu/RSV/SARS-CoV-2, which is important for ensuring accuracy of diagnosis at all stages of a respiratory infection.</p></div>\",\"PeriodicalId\":15517,\"journal\":{\"name\":\"Journal of Clinical Virology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.0000,\"publicationDate\":\"2024-04-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1386653224000362/pdfft?md5=7458aa65c3c562d9f5fef2f7548a65a6&pid=1-s2.0-S1386653224000362-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Virology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1386653224000362\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VIROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Virology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1386653224000362","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VIROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景快速、准确地检测病毒性呼吸道感染对感染控制措施非常重要。本研究比较了 Xpert® Xpress CoV-2/Flu/RSV plus 检测试剂盒("Xpert",Cepheid 公司)和 STANDARD™ M10 Flu/RSV/SARS-CoV-2 检测试剂盒("M10",SD Biosensor 公司)的分析和临床性能。这两种检测方法都是用于快速诊断 SARS-CoV-2、甲型/乙型流感和 RSV 的四重 RT-PCR 检测方法。结果对于 SARS-CoV-2、甲型流感、乙型流感和 RSV,Xpert 和 M10 检验的分析灵敏度分别为 10、50、50 和 300 对 300、200、800 和 1500 拷贝/毫升。与 M10 检测法相比,Xpert 检测法对所有四种病原体的临床灵敏度都更高。Xpert对所有四种病原体在所有Ct范围内的临床灵敏度均为100%,而M10对四种病原体在25-30 Ct范围内的临床灵敏度为100%,在30-35 Ct范围内为84-100%,在>35 Ct范围内为47-67%。这项研究表明,与 STANDARD M10 流感/RSV/SARS-CoV-2 相比,Xpert Xpress CoV-2/Flu/RSV plus 的分析和临床性能都有所提高,这对确保呼吸道感染各阶段诊断的准确性非常重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of the analytical and clinical performance of two RT-PCR based point-of-care tests; Cepheid Xpert® Xpress CoV-2/Flu/RSV plus and SD BioSensor STANDARD™ M10 Flu/RSV/SARS-CoV-2

Background

Rapid and accurate detection of viral respiratory infections is important for infection control measures. This study compares the analytical and clinical performance of the Xpert® Xpress CoV-2/Flu/RSV plus test (“Xpert”, Cepheid) and the STANDARD™ M10 Flu/RSV/SARS-CoV-2 test (“M10”, SD Biosensor). Both tests are quadruplex RT-PCR assays for rapid diagnosis of SARS-CoV-2, influenza A/B and RSV.

Study design

Analytical sensitivities were determined by limit of detection for SARS-CoV-2, influenza A, influenza B and RSV, respectively. Additionally, the clinical performance of the Xpert and the M10 tests was evaluated against standard-of-care RT-PCR by testing of 492 clinical specimens.

Results

The analytical sensitivities for Xpert versus M10 test was 10, 50, 50 and 300 versus 300, 200, 800 and 1500 copies/mL for SARS-CoV-2, influenza A, influenza B and RSV, respectively. Clinical sensitivity for the Xpert test was superior across all four pathogens compared to the M10 test. Xpert showed clinical sensitivity of 100 % in all Ct-ranges for all four pathogens whereas M10 showed clinical sensitivity of 100 % in the 25–30 Ct-range, 84–100 % in the 30–35 Ct-range and 47–67 % in the >35 Ct-range across the four pathogens. Translating into real-life clinical sensitivity, the Xpert would detect 100 % of all four pathogens, whereas M10 would detect 92.1, 92.4, 84.8 and 94.7 % for SARS-CoV-2, influenza A, influenza B and RSV.

Conclusion

This study demonstrates improved analytical and clinical performance of Xpert Xpress CoV-2/Flu/RSV plus compared to STANDARD M10 Flu/RSV/SARS-CoV-2, which is important for ensuring accuracy of diagnosis at all stages of a respiratory infection.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Clinical Virology
Journal of Clinical Virology 医学-病毒学
CiteScore
22.70
自引率
1.10%
发文量
149
审稿时长
24 days
期刊介绍: The Journal of Clinical Virology, an esteemed international publication, serves as the official journal for both the Pan American Society for Clinical Virology and The European Society for Clinical Virology. Dedicated to advancing the understanding of human virology in clinical settings, the Journal of Clinical Virology focuses on disseminating research papers and reviews pertaining to the clinical aspects of virology. Its scope encompasses articles discussing diagnostic methodologies and virus-induced clinical conditions, with an emphasis on practicality and relevance to clinical practice. The journal publishes on topics that include: • new diagnostic technologies • nucleic acid amplification and serologic testing • targeted and metagenomic next-generation sequencing • emerging pandemic viral threats • respiratory viruses • transplant viruses • chronic viral infections • cancer-associated viruses • gastrointestinal viruses • central nervous system viruses • one health (excludes animal health)
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信