Louise C. Kelly, Joanne V. Glinsky, Lisa A. Harvey
{"title":"关于三名患者在注射 0.02% Uro-Tainer® 聚己内酯后出现顽固性自主神经反射障碍的病例报告","authors":"Louise C. Kelly, Joanne V. Glinsky, Lisa A. Harvey","doi":"10.1038/s41394-024-00626-5","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Introduction</h3><p>Historically, bladder washouts were used to instil therapeutic reagents directly into the bladder. This practice has expanded to include instillation of solutions that deal with catheter issues such as encrustation or formation of bio-film. They appear to provide a promising strategy for people with long term catheters. These products are readily available to purchase, but there is concern that people are using these solutions without a complete understanding of the purpose for the rinse and without clinical guidance to monitor response to treatment.</p><h3 data-test=\"abstract-sub-heading\">Case presentation</h3><p>These case studies include three people living with spinal cord injury (SCI) who developed severe autonomic dysreflexia (AD) when a catheter rinse was carried out using a particular solution. Each of the cases developed immediate and, in some cases, intractable AD requiring further intervention to resolve symptoms.</p><h3 data-test=\"abstract-sub-heading\">Discussion</h3><p>Catheter-associated urinary tract infection is a significant cause of morbidity and mortality in people living with SCI. Long-term catheters provide a vector for opportunistic micro-organisms to form bio-film and create an environment that promotes formation of struvite calculi, thus increasing the risk of chronic catheter blockage and urinary tract infection. Whilst these solutions are used to reduce these risks, they also pose additional risks to people susceptible to AD. These cases highlight the need for judicious patient selection and clinical oversight and management of adverse events when using catheter rinse solutions in certain people living with SCI. This is supported by a decision-making algorithm and a response to AD algorithm.</p><p>This case report was prepared following the CARE Guidelines (supplementary file 1).</p>","PeriodicalId":22079,"journal":{"name":"Spinal Cord Series and Cases","volume":null,"pages":null},"PeriodicalIF":0.7000,"publicationDate":"2024-04-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A case report of three people experiencing intractable autonomic dysreflexia following instillation of Uro-Tainer® Polyhexanide 0.02%\",\"authors\":\"Louise C. Kelly, Joanne V. Glinsky, Lisa A. Harvey\",\"doi\":\"10.1038/s41394-024-00626-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3 data-test=\\\"abstract-sub-heading\\\">Introduction</h3><p>Historically, bladder washouts were used to instil therapeutic reagents directly into the bladder. This practice has expanded to include instillation of solutions that deal with catheter issues such as encrustation or formation of bio-film. They appear to provide a promising strategy for people with long term catheters. These products are readily available to purchase, but there is concern that people are using these solutions without a complete understanding of the purpose for the rinse and without clinical guidance to monitor response to treatment.</p><h3 data-test=\\\"abstract-sub-heading\\\">Case presentation</h3><p>These case studies include three people living with spinal cord injury (SCI) who developed severe autonomic dysreflexia (AD) when a catheter rinse was carried out using a particular solution. Each of the cases developed immediate and, in some cases, intractable AD requiring further intervention to resolve symptoms.</p><h3 data-test=\\\"abstract-sub-heading\\\">Discussion</h3><p>Catheter-associated urinary tract infection is a significant cause of morbidity and mortality in people living with SCI. Long-term catheters provide a vector for opportunistic micro-organisms to form bio-film and create an environment that promotes formation of struvite calculi, thus increasing the risk of chronic catheter blockage and urinary tract infection. Whilst these solutions are used to reduce these risks, they also pose additional risks to people susceptible to AD. These cases highlight the need for judicious patient selection and clinical oversight and management of adverse events when using catheter rinse solutions in certain people living with SCI. This is supported by a decision-making algorithm and a response to AD algorithm.</p><p>This case report was prepared following the CARE Guidelines (supplementary file 1).</p>\",\"PeriodicalId\":22079,\"journal\":{\"name\":\"Spinal Cord Series and Cases\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2024-04-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Spinal Cord Series and Cases\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1038/s41394-024-00626-5\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Spinal Cord Series and Cases","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1038/s41394-024-00626-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
摘要
导言历史上,膀胱冲洗用于将治疗试剂直接灌入膀胱。这种做法已扩展到灌注解决导尿管问题(如结壳或形成生物膜)的溶液。这些产品似乎为长期使用导尿管的人提供了一种很有前景的策略。这些病例研究包括三名脊髓损伤 (SCI) 患者,他们在使用特定溶液冲洗导管时出现了严重的自主反射障碍 (AD)。讨论导尿管相关性尿路感染是 SCI 患者发病和死亡的一个重要原因。长期导尿管为机会性微生物提供了形成生物膜的载体,并创造了促进形成结石的环境,从而增加了慢性导尿管堵塞和尿路感染的风险。虽然使用这些溶液是为了降低这些风险,但它们也给易患 AD 的人带来了额外的风险。这些病例突出表明,在对某些 SCI 患者使用导尿管冲洗溶液时,需要明智地选择患者,并对不良事件进行临床监督和管理。本病例报告是根据 CARE 指南(补充文件 1)编写的。
A case report of three people experiencing intractable autonomic dysreflexia following instillation of Uro-Tainer® Polyhexanide 0.02%
Introduction
Historically, bladder washouts were used to instil therapeutic reagents directly into the bladder. This practice has expanded to include instillation of solutions that deal with catheter issues such as encrustation or formation of bio-film. They appear to provide a promising strategy for people with long term catheters. These products are readily available to purchase, but there is concern that people are using these solutions without a complete understanding of the purpose for the rinse and without clinical guidance to monitor response to treatment.
Case presentation
These case studies include three people living with spinal cord injury (SCI) who developed severe autonomic dysreflexia (AD) when a catheter rinse was carried out using a particular solution. Each of the cases developed immediate and, in some cases, intractable AD requiring further intervention to resolve symptoms.
Discussion
Catheter-associated urinary tract infection is a significant cause of morbidity and mortality in people living with SCI. Long-term catheters provide a vector for opportunistic micro-organisms to form bio-film and create an environment that promotes formation of struvite calculi, thus increasing the risk of chronic catheter blockage and urinary tract infection. Whilst these solutions are used to reduce these risks, they also pose additional risks to people susceptible to AD. These cases highlight the need for judicious patient selection and clinical oversight and management of adverse events when using catheter rinse solutions in certain people living with SCI. This is supported by a decision-making algorithm and a response to AD algorithm.
This case report was prepared following the CARE Guidelines (supplementary file 1).