Meifeng Ren, Wei Xuan Chan, Laura Green, Martin L. Buist, Choon Hwai Yap
{"title":"胎儿心脏健康时和主动脉瓣严重狭窄时的双心室有限元建模","authors":"Meifeng Ren, Wei Xuan Chan, Laura Green, Martin L. Buist, Choon Hwai Yap","doi":"10.1007/s10237-024-01842-6","DOIUrl":null,"url":null,"abstract":"<div><p>Finite Element simulations are a robust way of investigating cardiac biomechanics. To date, it has only been performed with the left ventricle (LV) alone for fetal hearts, even though results are likely different with biventricular (BiV) simulations. In this research, we conduct BiV simulations of the fetal heart based on 4D echocardiography images to show that it can capture the biomechanics of the normal healthy fetal heart, as well as those of fetal aortic stenosis better than the LV alone simulations. We found that performing LV alone simulations resulted in overestimation of LV stresses and pressures, compared to BiV simulations. Interestingly, inserting a compliance between the LV and right ventricle (RV) in the lumped parameter model of the LV only simulation effectively resolved these overestimations, demonstrating that the septum could be considered to play a LV-RV pressure communication role. However, stresses and strains spatial patterns remained altered from BiV simulations after the addition of the compliance. The BiV simulations corroborated previous studies in showing disease effects on the LV, where fetal aortic stenosis (AS) drastically elevated LV pressures and reduced strains and stroke volumes, which were moderated down with the addition of mitral regurgitation (MR). However, BiV simulations enabled an evaluation of the RV as well, where we observed that effects of the AS and MR on pressures and stroke volumes were generally much smaller and less consistent. The BiV simulations also enabled investigations of septal dynamics, which showed a rightward shift with AS, and partial restoration with MR. Interestingly, AS tended to enhance RV stroke volume, but MR moderated that down.</p></div>","PeriodicalId":489,"journal":{"name":"Biomechanics and Modeling in Mechanobiology","volume":"23 4","pages":"1331 - 1345"},"PeriodicalIF":3.0000,"publicationDate":"2024-04-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biventricular finite element modeling of the fetal heart in health and during critical aortic stenosis\",\"authors\":\"Meifeng Ren, Wei Xuan Chan, Laura Green, Martin L. Buist, Choon Hwai Yap\",\"doi\":\"10.1007/s10237-024-01842-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Finite Element simulations are a robust way of investigating cardiac biomechanics. To date, it has only been performed with the left ventricle (LV) alone for fetal hearts, even though results are likely different with biventricular (BiV) simulations. In this research, we conduct BiV simulations of the fetal heart based on 4D echocardiography images to show that it can capture the biomechanics of the normal healthy fetal heart, as well as those of fetal aortic stenosis better than the LV alone simulations. We found that performing LV alone simulations resulted in overestimation of LV stresses and pressures, compared to BiV simulations. Interestingly, inserting a compliance between the LV and right ventricle (RV) in the lumped parameter model of the LV only simulation effectively resolved these overestimations, demonstrating that the septum could be considered to play a LV-RV pressure communication role. However, stresses and strains spatial patterns remained altered from BiV simulations after the addition of the compliance. The BiV simulations corroborated previous studies in showing disease effects on the LV, where fetal aortic stenosis (AS) drastically elevated LV pressures and reduced strains and stroke volumes, which were moderated down with the addition of mitral regurgitation (MR). However, BiV simulations enabled an evaluation of the RV as well, where we observed that effects of the AS and MR on pressures and stroke volumes were generally much smaller and less consistent. The BiV simulations also enabled investigations of septal dynamics, which showed a rightward shift with AS, and partial restoration with MR. Interestingly, AS tended to enhance RV stroke volume, but MR moderated that down.</p></div>\",\"PeriodicalId\":489,\"journal\":{\"name\":\"Biomechanics and Modeling in Mechanobiology\",\"volume\":\"23 4\",\"pages\":\"1331 - 1345\"},\"PeriodicalIF\":3.0000,\"publicationDate\":\"2024-04-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomechanics and Modeling in Mechanobiology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10237-024-01842-6\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOPHYSICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomechanics and Modeling in Mechanobiology","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10237-024-01842-6","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOPHYSICS","Score":null,"Total":0}
Biventricular finite element modeling of the fetal heart in health and during critical aortic stenosis
Finite Element simulations are a robust way of investigating cardiac biomechanics. To date, it has only been performed with the left ventricle (LV) alone for fetal hearts, even though results are likely different with biventricular (BiV) simulations. In this research, we conduct BiV simulations of the fetal heart based on 4D echocardiography images to show that it can capture the biomechanics of the normal healthy fetal heart, as well as those of fetal aortic stenosis better than the LV alone simulations. We found that performing LV alone simulations resulted in overestimation of LV stresses and pressures, compared to BiV simulations. Interestingly, inserting a compliance between the LV and right ventricle (RV) in the lumped parameter model of the LV only simulation effectively resolved these overestimations, demonstrating that the septum could be considered to play a LV-RV pressure communication role. However, stresses and strains spatial patterns remained altered from BiV simulations after the addition of the compliance. The BiV simulations corroborated previous studies in showing disease effects on the LV, where fetal aortic stenosis (AS) drastically elevated LV pressures and reduced strains and stroke volumes, which were moderated down with the addition of mitral regurgitation (MR). However, BiV simulations enabled an evaluation of the RV as well, where we observed that effects of the AS and MR on pressures and stroke volumes were generally much smaller and less consistent. The BiV simulations also enabled investigations of septal dynamics, which showed a rightward shift with AS, and partial restoration with MR. Interestingly, AS tended to enhance RV stroke volume, but MR moderated that down.
期刊介绍:
Mechanics regulates biological processes at the molecular, cellular, tissue, organ, and organism levels. A goal of this journal is to promote basic and applied research that integrates the expanding knowledge-bases in the allied fields of biomechanics and mechanobiology. Approaches may be experimental, theoretical, or computational; they may address phenomena at the nano, micro, or macrolevels. Of particular interest are investigations that
(1) quantify the mechanical environment in which cells and matrix function in health, disease, or injury,
(2) identify and quantify mechanosensitive responses and their mechanisms,
(3) detail inter-relations between mechanics and biological processes such as growth, remodeling, adaptation, and repair, and
(4) report discoveries that advance therapeutic and diagnostic procedures.
Especially encouraged are analytical and computational models based on solid mechanics, fluid mechanics, or thermomechanics, and their interactions; also encouraged are reports of new experimental methods that expand measurement capabilities and new mathematical methods that facilitate analysis.