为合并白内障和角膜炎并可选择屈光性人工晶体置换的患者选择人工晶体的功能性方法

IF 2.9 3区 医学 Q1 OPHTHALMOLOGY
Gunnar J. Goebel, MD, David A. Price, MD, Marianne O. Price, PhD, MBA, Francis W. Price Jr, MD
{"title":"为合并白内障和角膜炎并可选择屈光性人工晶体置换的患者选择人工晶体的功能性方法","authors":"Gunnar J. Goebel, MD, David A. Price, MD, Marianne O. Price, PhD, MBA, Francis W. Price Jr, MD","doi":"10.3928/1081597x-20240311-01","DOIUrl":null,"url":null,"abstract":"<section><h3>Purpose:</h3><p>To evaluate spherical intraocular lens (IOL) implantation for cataracts in keratoconic eyes followed by optional refractive toric lens exchange to improve uncorrected visual acuity.</p></section><section><h3>Methods:</h3><p>This retrospective study evaluated cataract surgery outcomes in keratoconic eyes. Eyes treated with a spherical IOL targeted for -2.00 diopters (D) either achieved acceptable manifest refraction and desired exchange with a toric IOL (Group 1); achieved satisfactory manifest refraction and chose to use spectacles or contact lenses (Group 2); or did not achieve acceptable refraction and used contact lenses (Group 3). Group 4 had single-stage toric IOL implantation with plano target. Corrected and uncorrected distance visual acuity (CDVA and UDVA) and keratometry were analyzed.</p></section><section><h3>Results:</h3><p>Groups 1 to 4 had 18, 23, 18, and 26 eyes, respectively. A staged toric exchange resulted in significantly better (<i>P</i> = .02) UDVA (mean: 0.15 logMAR; 20/25 Snellen) than initial toric IOL implantation (0.24 logMAR; 20/30 Snellen). All toric IOL exchange eyes achieved 20/30 or better CDVA and 94% had 20/40 or better UDVA. Mean manifest cylinder significantly decreased from 3.39 D before lens exchange to 1.10 D postoperatively.</p></section><section><h3>Conclusions:</h3><p>Initial implantation of a spherical IOL in keratoconic eyes allows basing toric calculations on the manifest refraction, which may be more reliable than keratometry measurements in keratoconic eyes. UDVA after staged toric IOL exchange was significantly better than after initial toric IOL implantation. Importantly, by staging use of toric lenses, the authors avoided cases where patients required a rigid contact lens after a toric IOL was implanted.</p><p><strong>[<i>J Refract Surg</i>. 2024;40(4):e207–e217.]</strong></p></section>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"57 1","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2024-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Functional Approach to IOL Selection in Eyes With Combined Cataract and Keratoconus With an Option for Refractive Lens Exchange\",\"authors\":\"Gunnar J. Goebel, MD, David A. Price, MD, Marianne O. Price, PhD, MBA, Francis W. Price Jr, MD\",\"doi\":\"10.3928/1081597x-20240311-01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<section><h3>Purpose:</h3><p>To evaluate spherical intraocular lens (IOL) implantation for cataracts in keratoconic eyes followed by optional refractive toric lens exchange to improve uncorrected visual acuity.</p></section><section><h3>Methods:</h3><p>This retrospective study evaluated cataract surgery outcomes in keratoconic eyes. Eyes treated with a spherical IOL targeted for -2.00 diopters (D) either achieved acceptable manifest refraction and desired exchange with a toric IOL (Group 1); achieved satisfactory manifest refraction and chose to use spectacles or contact lenses (Group 2); or did not achieve acceptable refraction and used contact lenses (Group 3). Group 4 had single-stage toric IOL implantation with plano target. Corrected and uncorrected distance visual acuity (CDVA and UDVA) and keratometry were analyzed.</p></section><section><h3>Results:</h3><p>Groups 1 to 4 had 18, 23, 18, and 26 eyes, respectively. A staged toric exchange resulted in significantly better (<i>P</i> = .02) UDVA (mean: 0.15 logMAR; 20/25 Snellen) than initial toric IOL implantation (0.24 logMAR; 20/30 Snellen). All toric IOL exchange eyes achieved 20/30 or better CDVA and 94% had 20/40 or better UDVA. Mean manifest cylinder significantly decreased from 3.39 D before lens exchange to 1.10 D postoperatively.</p></section><section><h3>Conclusions:</h3><p>Initial implantation of a spherical IOL in keratoconic eyes allows basing toric calculations on the manifest refraction, which may be more reliable than keratometry measurements in keratoconic eyes. UDVA after staged toric IOL exchange was significantly better than after initial toric IOL implantation. Importantly, by staging use of toric lenses, the authors avoided cases where patients required a rigid contact lens after a toric IOL was implanted.</p><p><strong>[<i>J Refract Surg</i>. 2024;40(4):e207–e217.]</strong></p></section>\",\"PeriodicalId\":16951,\"journal\":{\"name\":\"Journal of refractive surgery\",\"volume\":\"57 1\",\"pages\":\"\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3928/1081597x-20240311-01\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597x-20240311-01","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估在角膜病变眼球内植入球面人工晶体(IOL)治疗白内障后,通过选择性屈光性散光人工晶体交换来改善未矫正视力的效果。方法:这项回顾性研究评估了角膜病变眼球内植入球面人工晶体治疗白内障手术的效果。使用以-2.00屈光度(D)为目标的球面人工晶体治疗的患者,有的达到了可接受的屈光度,希望更换散光人工晶体(第1组);有的达到了满意的屈光度,选择使用眼镜或隐形眼镜(第2组);有的未达到可接受的屈光度,使用隐形眼镜(第3组)。第 4 组植入了单级散光人工晶体,目标为平面。结果:第 1 至第 4 组分别有 18、23、18 和 26 只眼睛。与初次植入散光人工晶体(0.24 logMAR; 20/30 Snellen)相比,分阶段进行散光人工晶体置换的 UDVA(平均:0.15 logMAR; 20/25 Snellen)明显更好(P = .02)。所有更换过散光人工晶体的眼睛 CDVA 均达到 20/30 或更高,94% 的眼睛 UDVA 达到 20/40 或更高。结论:在角膜病变眼中初次植入球面人工晶体时,可根据屈光度数计算散光,这可能比角膜屈光度测量更可靠。分期更换散光人工晶体后的 UDVA 明显优于初次植入散光人工晶体后的 UDVA。重要的是,通过分期使用散光人工晶体,作者避免了患者在植入散光人工晶体后需要硬性隐形眼镜的情况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Functional Approach to IOL Selection in Eyes With Combined Cataract and Keratoconus With an Option for Refractive Lens Exchange

Purpose:

To evaluate spherical intraocular lens (IOL) implantation for cataracts in keratoconic eyes followed by optional refractive toric lens exchange to improve uncorrected visual acuity.

Methods:

This retrospective study evaluated cataract surgery outcomes in keratoconic eyes. Eyes treated with a spherical IOL targeted for -2.00 diopters (D) either achieved acceptable manifest refraction and desired exchange with a toric IOL (Group 1); achieved satisfactory manifest refraction and chose to use spectacles or contact lenses (Group 2); or did not achieve acceptable refraction and used contact lenses (Group 3). Group 4 had single-stage toric IOL implantation with plano target. Corrected and uncorrected distance visual acuity (CDVA and UDVA) and keratometry were analyzed.

Results:

Groups 1 to 4 had 18, 23, 18, and 26 eyes, respectively. A staged toric exchange resulted in significantly better (P = .02) UDVA (mean: 0.15 logMAR; 20/25 Snellen) than initial toric IOL implantation (0.24 logMAR; 20/30 Snellen). All toric IOL exchange eyes achieved 20/30 or better CDVA and 94% had 20/40 or better UDVA. Mean manifest cylinder significantly decreased from 3.39 D before lens exchange to 1.10 D postoperatively.

Conclusions:

Initial implantation of a spherical IOL in keratoconic eyes allows basing toric calculations on the manifest refraction, which may be more reliable than keratometry measurements in keratoconic eyes. UDVA after staged toric IOL exchange was significantly better than after initial toric IOL implantation. Importantly, by staging use of toric lenses, the authors avoided cases where patients required a rigid contact lens after a toric IOL was implanted.

[J Refract Surg. 2024;40(4):e207–e217.]

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
12.50%
发文量
160
审稿时长
4-8 weeks
期刊介绍: The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as: • Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics” • Supplemental videos and materials available for many articles • Access to current articles, as well as several years of archived content • Articles posted online just 2 months after acceptance.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信