采用各种技术加固后受火灾损坏的 RC 梁的行为

Asser M. Elsheikh, H. H. Alzamili
{"title":"采用各种技术加固后受火灾损坏的 RC 梁的行为","authors":"Asser M. Elsheikh, H. H. Alzamili","doi":"10.28991/cej-2024-010-01-012","DOIUrl":null,"url":null,"abstract":"High temperatures during a fire can significantly degrade the structural capacity of concrete. However, in many cases, it is possible to restore and strengthen fire-damaged concrete rather than completely rebuild damaged structures. The study considered two types of concrete (normal 25 MPa and high-strength 65 MPa) with two types of strengthening techniques: carbon-fiber-reinforced polymers (CFRP) sheets with different thicknesses of 1.5 and 2.5 mm and slurry-infiltrated fibrous concrete (SIFCON) jacketing with different fiber sizes of 20 and 30 mm. The numerical simulations and analyses were conducted to capture the complex behavior of fire-damaged concrete members (beams). A fire-damaged concrete beam subjected to an extreme or critical fire Exposure time (2 hours) was evaluated and modified using a finite element simulation approach. The simulation process included three stages: the first, subjecting the concrete beam to thermal loading; the second, reflecting the fire distribution map to another model of applying mechanical loading; and the third, involving the application of strengthening to the damaged model. The results showed that the strengthening using CFRP with a thickness of 2.5 improved the load-carrying capacity compared with SIFCON in both types of concrete. 200% improvement for the normal-strength concrete beam and a 136% improvement for the high-strength concrete beam, compared to the damaged beams. Doi: 10.28991/CEJ-2024-010-01-012 Full Text: PDF","PeriodicalId":10233,"journal":{"name":"Civil Engineering Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Behavior of Fire-damaged RC Beams After Strengthening with Various Techniques\",\"authors\":\"Asser M. Elsheikh, H. H. Alzamili\",\"doi\":\"10.28991/cej-2024-010-01-012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"High temperatures during a fire can significantly degrade the structural capacity of concrete. However, in many cases, it is possible to restore and strengthen fire-damaged concrete rather than completely rebuild damaged structures. The study considered two types of concrete (normal 25 MPa and high-strength 65 MPa) with two types of strengthening techniques: carbon-fiber-reinforced polymers (CFRP) sheets with different thicknesses of 1.5 and 2.5 mm and slurry-infiltrated fibrous concrete (SIFCON) jacketing with different fiber sizes of 20 and 30 mm. The numerical simulations and analyses were conducted to capture the complex behavior of fire-damaged concrete members (beams). A fire-damaged concrete beam subjected to an extreme or critical fire Exposure time (2 hours) was evaluated and modified using a finite element simulation approach. The simulation process included three stages: the first, subjecting the concrete beam to thermal loading; the second, reflecting the fire distribution map to another model of applying mechanical loading; and the third, involving the application of strengthening to the damaged model. The results showed that the strengthening using CFRP with a thickness of 2.5 improved the load-carrying capacity compared with SIFCON in both types of concrete. 200% improvement for the normal-strength concrete beam and a 136% improvement for the high-strength concrete beam, compared to the damaged beams. Doi: 10.28991/CEJ-2024-010-01-012 Full Text: PDF\",\"PeriodicalId\":10233,\"journal\":{\"name\":\"Civil Engineering Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Civil Engineering Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.28991/cej-2024-010-01-012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Civil Engineering Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.28991/cej-2024-010-01-012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

火灾期间的高温会大大降低混凝土的结构承载能力。不过,在许多情况下,可以修复和加固被火损坏的混凝土,而不是完全重建受损结构。研究考虑了两种类型的混凝土(普通 25 兆帕和高强度 65 兆帕)和两种类型的加固技术:不同厚度(1.5 毫米和 2.5 毫米)的碳纤维增强聚合物(CFRP)片材和不同纤维尺寸(20 毫米和 30 毫米)的浆液渗透纤维混凝土(SIFCON)护套。进行数值模拟和分析的目的是捕捉受火灾破坏的混凝土构件(梁)的复杂行为。采用有限元模拟方法对遭受极端或临界火灾暴露时间(2 小时)的火灾损坏混凝土梁进行了评估和修改。模拟过程包括三个阶段:第一阶段,对混凝土梁施加热荷载;第二阶段,将火灾分布图反映到另一个施加机械荷载的模型上;第三阶段,对受损模型进行加固。结果表明,与 SIFCON 相比,使用厚度为 2.5 的 CFRP 加固可提高两种类型混凝土的承载能力。与受损梁相比,普通强度混凝土梁提高了 200%,高强度混凝土梁提高了 136%。Doi: 10.28991/CEJ-2024-010-012 全文:PDF
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Behavior of Fire-damaged RC Beams After Strengthening with Various Techniques
High temperatures during a fire can significantly degrade the structural capacity of concrete. However, in many cases, it is possible to restore and strengthen fire-damaged concrete rather than completely rebuild damaged structures. The study considered two types of concrete (normal 25 MPa and high-strength 65 MPa) with two types of strengthening techniques: carbon-fiber-reinforced polymers (CFRP) sheets with different thicknesses of 1.5 and 2.5 mm and slurry-infiltrated fibrous concrete (SIFCON) jacketing with different fiber sizes of 20 and 30 mm. The numerical simulations and analyses were conducted to capture the complex behavior of fire-damaged concrete members (beams). A fire-damaged concrete beam subjected to an extreme or critical fire Exposure time (2 hours) was evaluated and modified using a finite element simulation approach. The simulation process included three stages: the first, subjecting the concrete beam to thermal loading; the second, reflecting the fire distribution map to another model of applying mechanical loading; and the third, involving the application of strengthening to the damaged model. The results showed that the strengthening using CFRP with a thickness of 2.5 improved the load-carrying capacity compared with SIFCON in both types of concrete. 200% improvement for the normal-strength concrete beam and a 136% improvement for the high-strength concrete beam, compared to the damaged beams. Doi: 10.28991/CEJ-2024-010-01-012 Full Text: PDF
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信