超声监测下腔静脉以评估髋关节置换术中的栓塞现象

IF 0.9 Q3 ANESTHESIOLOGY
{"title":"超声监测下腔静脉以评估髋关节置换术中的栓塞现象","authors":"","doi":"10.1016/j.redar.2023.06.003","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction and objectives</h3><p>Embolic phenomena frequently occur during hip joint replacement surgery, and may lead to haemodynamic instability in frail patients. Transoesophageal ultrasound monitoring is rarely available in non-cardiac operating theatres, and cannot be performed in awake patients under spinal anaesthesia. The main objectives of this prospective exploratory study were to determine the feasibility of using an alternative ultrasound approach to monitor the inferior vena cava during hip replacement surgery, and to determine the intra- and interobserver reliability of the ultrasound findings.</p></div><div><h3>Method</h3><p>We conducted a prospective exploratory study in 20 patients undergoing cemented hip arthroplasty in the supine position under spinal anaesthesia and sedation. The inferior vena cava was assessed through a subcostal window at 10 intraoperative time points, and the findings were rated on a qualitative embolism severity scale. The ultrasound images were evaluated by 2 independent observers.</p></div><div><h3>Results</h3><p>An adequate subcostal window was obtained in 90% of cases. Intra- and inter-observer reliability was high (kappa index<!--> <!-->&gt;<!--> <!-->0.80, p<!--> <!-->&lt;<!--> <!-->0.001). Nearly all (95%) patients presented some degree of embolism, which was severe in 50% of cases.</p></div><div><h3>Conclusions</h3><p>Our study suggests that ultrasound assessment of embolic phenomena in the inferior vena cava through a subcostal window is reliable in 90% of cases. The qualitative embolic severity rating scale is highly reproducible and has high intra- and inter-observer reliability.</p></div>","PeriodicalId":46479,"journal":{"name":"Revista Espanola de Anestesiologia y Reanimacion","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Monitorización sonográfica de la vena cava inferior para la valoración de fenómenos embólicos durante la artroplastia de cadera\",\"authors\":\"\",\"doi\":\"10.1016/j.redar.2023.06.003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction and objectives</h3><p>Embolic phenomena frequently occur during hip joint replacement surgery, and may lead to haemodynamic instability in frail patients. Transoesophageal ultrasound monitoring is rarely available in non-cardiac operating theatres, and cannot be performed in awake patients under spinal anaesthesia. The main objectives of this prospective exploratory study were to determine the feasibility of using an alternative ultrasound approach to monitor the inferior vena cava during hip replacement surgery, and to determine the intra- and interobserver reliability of the ultrasound findings.</p></div><div><h3>Method</h3><p>We conducted a prospective exploratory study in 20 patients undergoing cemented hip arthroplasty in the supine position under spinal anaesthesia and sedation. The inferior vena cava was assessed through a subcostal window at 10 intraoperative time points, and the findings were rated on a qualitative embolism severity scale. The ultrasound images were evaluated by 2 independent observers.</p></div><div><h3>Results</h3><p>An adequate subcostal window was obtained in 90% of cases. Intra- and inter-observer reliability was high (kappa index<!--> <!-->&gt;<!--> <!-->0.80, p<!--> <!-->&lt;<!--> <!-->0.001). Nearly all (95%) patients presented some degree of embolism, which was severe in 50% of cases.</p></div><div><h3>Conclusions</h3><p>Our study suggests that ultrasound assessment of embolic phenomena in the inferior vena cava through a subcostal window is reliable in 90% of cases. The qualitative embolic severity rating scale is highly reproducible and has high intra- and inter-observer reliability.</p></div>\",\"PeriodicalId\":46479,\"journal\":{\"name\":\"Revista Espanola de Anestesiologia y Reanimacion\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Revista Espanola de Anestesiologia y Reanimacion\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0034935624000100\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Revista Espanola de Anestesiologia y Reanimacion","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0034935624000100","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

导言和目的髋关节置换手术过程中经常会出现象征性现象,可能会导致体弱患者的血流动力学不稳定。经食道超声监测在非心脏手术室很少使用,而且无法在脊髓麻醉下对清醒患者进行监测。这项前瞻性探索研究的主要目的是确定在髋关节置换手术中使用另一种超声方法监测下腔静脉的可行性,并确定超声结果在观察者内部和观察者之间的可靠性。在术中的 10 个时间点,通过肋下开窗对下腔静脉进行评估,并根据栓塞严重程度定性评分。结果 90%的病例都获得了适当的肋下开窗。观察者内部和观察者之间的可靠性很高(卡帕指数为 0.80,p 为 0.001)。结论我们的研究表明,通过肋下开窗对下腔静脉栓塞现象进行超声评估在 90% 的病例中都是可靠的。栓塞严重程度定性评分表的重复性很高,观察者内部和观察者之间的可靠性也很高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Monitorización sonográfica de la vena cava inferior para la valoración de fenómenos embólicos durante la artroplastia de cadera

Monitorización sonográfica de la vena cava inferior para la valoración de fenómenos embólicos durante la artroplastia de cadera

Introduction and objectives

Embolic phenomena frequently occur during hip joint replacement surgery, and may lead to haemodynamic instability in frail patients. Transoesophageal ultrasound monitoring is rarely available in non-cardiac operating theatres, and cannot be performed in awake patients under spinal anaesthesia. The main objectives of this prospective exploratory study were to determine the feasibility of using an alternative ultrasound approach to monitor the inferior vena cava during hip replacement surgery, and to determine the intra- and interobserver reliability of the ultrasound findings.

Method

We conducted a prospective exploratory study in 20 patients undergoing cemented hip arthroplasty in the supine position under spinal anaesthesia and sedation. The inferior vena cava was assessed through a subcostal window at 10 intraoperative time points, and the findings were rated on a qualitative embolism severity scale. The ultrasound images were evaluated by 2 independent observers.

Results

An adequate subcostal window was obtained in 90% of cases. Intra- and inter-observer reliability was high (kappa index > 0.80, p < 0.001). Nearly all (95%) patients presented some degree of embolism, which was severe in 50% of cases.

Conclusions

Our study suggests that ultrasound assessment of embolic phenomena in the inferior vena cava through a subcostal window is reliable in 90% of cases. The qualitative embolic severity rating scale is highly reproducible and has high intra- and inter-observer reliability.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.80
自引率
15.40%
发文量
113
审稿时长
82 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信