Mina Sadat Khoramian Esfahani, Ghazaleh Ahmadi, B. Esmaeili
{"title":"CAD-CAM 陶瓷的抛光与上釉对对位复合树脂的磨损和表面粗糙度的影响","authors":"Mina Sadat Khoramian Esfahani, Ghazaleh Ahmadi, B. Esmaeili","doi":"10.4103/drj.drj_757_22","DOIUrl":null,"url":null,"abstract":"Background: This study aimed to assess the effect of polishing versus glazing of computer-aided design-computer-aided manufacturing (CAD-CAM) ceramics on depth of wear and surface roughness of opposing composite resin. Materials and Methods: This in vitro study was conducted on 40 Z250 composite and 40 CAD-CAM ceramic specimens including Celtra Duo, Vita Mark II, e.max CAD, and Vita Suprinity ceramics. All ceramic specimens were roughened by a fine-grit bur after primary glazing to simulate an adjusted surface in the clinical setting. They were then randomly assigned to two subgroups and underwent reglazing or polishing. All composite and ceramic specimens underwent profilometry after surface treatment and prior to the wear test, and the results were recorded quantitatively. Composite specimens were then subjected to 120,000 wear cycles against ceramic specimens in a chewing simulator, and the depth of wear was measured by a scanner. Data were statistically analyzed by repeated measures two-way analysis of variance (ANOVA) and one-way ANOVA (α = 0.05). Results: Comparison of the surface roughness of composite specimens before and after the wear test revealed significant differences in both glazed Suprinity (P = 0.048) and Vita Mark II (P = 0.026) ceramics groups. The change in surface roughness after the wear test (compared with baseline) was significant in glazed (P = 0.000) and polished (P = 0.013) Vita Mark II and polished Suprinity (P = 0.037) ceramics, but this change was not significant in other ceramics (P > 0.05). The depth of wear after the wear test was not significantly different among the ceramic and composite subgroups (P > 0.05). Conclusion: Assessment of depth of wear and surface roughness of composite specimens showed that the polishing kits of CAD-CAM ceramics can serve as a suitable alternative to reglazing.","PeriodicalId":11016,"journal":{"name":"Dental Research Journal","volume":"509 22","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of polishing versus glazing of CAD-CAM ceramics on wear and surface roughness of opposing composite resin\",\"authors\":\"Mina Sadat Khoramian Esfahani, Ghazaleh Ahmadi, B. Esmaeili\",\"doi\":\"10.4103/drj.drj_757_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: This study aimed to assess the effect of polishing versus glazing of computer-aided design-computer-aided manufacturing (CAD-CAM) ceramics on depth of wear and surface roughness of opposing composite resin. Materials and Methods: This in vitro study was conducted on 40 Z250 composite and 40 CAD-CAM ceramic specimens including Celtra Duo, Vita Mark II, e.max CAD, and Vita Suprinity ceramics. All ceramic specimens were roughened by a fine-grit bur after primary glazing to simulate an adjusted surface in the clinical setting. They were then randomly assigned to two subgroups and underwent reglazing or polishing. All composite and ceramic specimens underwent profilometry after surface treatment and prior to the wear test, and the results were recorded quantitatively. Composite specimens were then subjected to 120,000 wear cycles against ceramic specimens in a chewing simulator, and the depth of wear was measured by a scanner. Data were statistically analyzed by repeated measures two-way analysis of variance (ANOVA) and one-way ANOVA (α = 0.05). Results: Comparison of the surface roughness of composite specimens before and after the wear test revealed significant differences in both glazed Suprinity (P = 0.048) and Vita Mark II (P = 0.026) ceramics groups. The change in surface roughness after the wear test (compared with baseline) was significant in glazed (P = 0.000) and polished (P = 0.013) Vita Mark II and polished Suprinity (P = 0.037) ceramics, but this change was not significant in other ceramics (P > 0.05). The depth of wear after the wear test was not significantly different among the ceramic and composite subgroups (P > 0.05). Conclusion: Assessment of depth of wear and surface roughness of composite specimens showed that the polishing kits of CAD-CAM ceramics can serve as a suitable alternative to reglazing.\",\"PeriodicalId\":11016,\"journal\":{\"name\":\"Dental Research Journal\",\"volume\":\"509 22\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental Research Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/drj.drj_757_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Research Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/drj.drj_757_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
摘要
背景:本研究旨在评估计算机辅助设计-计算机辅助制造(CAD-CAM)陶瓷的抛光与上釉对对位复合树脂的磨损深度和表面粗糙度的影响。材料和方法:这项体外研究针对 40 个 Z250 复合材料和 40 个 CAD-CAM 陶瓷试样(包括 Celtra Duo、Vita Mark II、e.max CAD 和 Vita Suprinity 陶瓷)进行。所有陶瓷试样在初釉后都用细磨毛刺进行了粗化处理,以模拟临床环境中的调整表面。然后将它们随机分配到两个亚组,并进行重新上釉或抛光。所有复合材料和陶瓷试样在表面处理后和磨损测试前都进行了轮廓测量,并对结果进行了定量记录。然后在咀嚼模拟器中对复合材料试样和陶瓷试样进行 120,000 次磨损循环,并用扫描仪测量磨损深度。数据通过重复测量双向方差分析(ANOVA)和单向方差分析(α = 0.05)进行统计分析。结果比较磨损测试前后复合材料试样的表面粗糙度发现,釉面 Suprinity(P = 0.048)和 Vita Mark II(P = 0.026)陶瓷组都存在显著差异。磨损测试后表面粗糙度的变化(与基线相比)在上釉(P = 0.000)和抛光(P = 0.013)的 Vita Mark II 陶瓷和抛光的 Suprinity(P = 0.037)陶瓷中显著,但在其他陶瓷中变化不显著(P > 0.05)。磨损测试后的磨损深度在陶瓷和复合材料亚组中没有明显差异(P > 0.05)。结论对复合材料试样的磨损深度和表面粗糙度的评估表明,CAD-CAM 陶瓷的抛光套件可以作为重新上釉的合适替代品。
Effect of polishing versus glazing of CAD-CAM ceramics on wear and surface roughness of opposing composite resin
Background: This study aimed to assess the effect of polishing versus glazing of computer-aided design-computer-aided manufacturing (CAD-CAM) ceramics on depth of wear and surface roughness of opposing composite resin. Materials and Methods: This in vitro study was conducted on 40 Z250 composite and 40 CAD-CAM ceramic specimens including Celtra Duo, Vita Mark II, e.max CAD, and Vita Suprinity ceramics. All ceramic specimens were roughened by a fine-grit bur after primary glazing to simulate an adjusted surface in the clinical setting. They were then randomly assigned to two subgroups and underwent reglazing or polishing. All composite and ceramic specimens underwent profilometry after surface treatment and prior to the wear test, and the results were recorded quantitatively. Composite specimens were then subjected to 120,000 wear cycles against ceramic specimens in a chewing simulator, and the depth of wear was measured by a scanner. Data were statistically analyzed by repeated measures two-way analysis of variance (ANOVA) and one-way ANOVA (α = 0.05). Results: Comparison of the surface roughness of composite specimens before and after the wear test revealed significant differences in both glazed Suprinity (P = 0.048) and Vita Mark II (P = 0.026) ceramics groups. The change in surface roughness after the wear test (compared with baseline) was significant in glazed (P = 0.000) and polished (P = 0.013) Vita Mark II and polished Suprinity (P = 0.037) ceramics, but this change was not significant in other ceramics (P > 0.05). The depth of wear after the wear test was not significantly different among the ceramic and composite subgroups (P > 0.05). Conclusion: Assessment of depth of wear and surface roughness of composite specimens showed that the polishing kits of CAD-CAM ceramics can serve as a suitable alternative to reglazing.
期刊介绍:
Dental Research Journal, a publication of Isfahan University of Medical Sciences, is a peer-reviewed online journal with Bimonthly print on demand compilation of issues published. The journal’s full text is available online at http://www.drjjournal.net. The journal allows free access (Open Access) to its contents and permits authors to self-archive final accepted version of the articles on any OAI-compliant institutional / subject-based repository. The journal will cover technical and clinical studies related to health, ethical and social issues in field of Dentistry. Articles with clinical interest and implications will be given preference.