Sandi Budi Kurniawan, Sugeng Purwanto, Ersalia Dewi Nursitao
{"title":"含有固体易燃材料的建筑物的空气终端避雷装置","authors":"Sandi Budi Kurniawan, Sugeng Purwanto, Ersalia Dewi Nursitao","doi":"10.46799/ajesh.v3i2.249","DOIUrl":null,"url":null,"abstract":"Damage to facilities and equipment in a building is mostly caused by lightning strikes so the installation of lightning rods is necessary to improve the protection of a building or building as a whole, both for the common good and for the government, so that various equipment and production activities that use various flammable materials (in the form of ) solid, liquid and gas) inside and around the building can be properly protected. Of the several existing lightning protection systems (LPS), this study uses a conventional type (franklin rod) as a LPS in factory buildings. From the results of this study, it can be stated that level IV protection of LPS is needed and multiply the number of lightning protection rods where a minimum of 4 rods for 1 building roof","PeriodicalId":505426,"journal":{"name":"Asian Journal of Engineering, Social and Health","volume":"124 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Air Termination Of Lightning Protection For The Buildings Which Containing Solid Flammable Materials\",\"authors\":\"Sandi Budi Kurniawan, Sugeng Purwanto, Ersalia Dewi Nursitao\",\"doi\":\"10.46799/ajesh.v3i2.249\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Damage to facilities and equipment in a building is mostly caused by lightning strikes so the installation of lightning rods is necessary to improve the protection of a building or building as a whole, both for the common good and for the government, so that various equipment and production activities that use various flammable materials (in the form of ) solid, liquid and gas) inside and around the building can be properly protected. Of the several existing lightning protection systems (LPS), this study uses a conventional type (franklin rod) as a LPS in factory buildings. From the results of this study, it can be stated that level IV protection of LPS is needed and multiply the number of lightning protection rods where a minimum of 4 rods for 1 building roof\",\"PeriodicalId\":505426,\"journal\":{\"name\":\"Asian Journal of Engineering, Social and Health\",\"volume\":\"124 \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Engineering, Social and Health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.46799/ajesh.v3i2.249\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Engineering, Social and Health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.46799/ajesh.v3i2.249","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
建筑物内设施和设备的损坏大多是由雷击造成的,因此,为了提高建筑物或建筑物整体的防护能力,无论是从公共利益还是从政府角度考虑,都有必要安装避雷针,以便建筑物内部和周围使用各种易燃材料(以)固体、液体和气体形式存在的各种设备和生产活动能够得到适当的保护。在现有的几种防雷系统(LPS)中,本研究采用传统型(法兰克林杆)作为工厂建筑的防雷系统。从研究结果来看,需要对防雷系统进行 IV 级保护,并成倍增加避雷针的数量,即 1 个建筑物屋顶至少需要 4 根避雷针。
Air Termination Of Lightning Protection For The Buildings Which Containing Solid Flammable Materials
Damage to facilities and equipment in a building is mostly caused by lightning strikes so the installation of lightning rods is necessary to improve the protection of a building or building as a whole, both for the common good and for the government, so that various equipment and production activities that use various flammable materials (in the form of ) solid, liquid and gas) inside and around the building can be properly protected. Of the several existing lightning protection systems (LPS), this study uses a conventional type (franklin rod) as a LPS in factory buildings. From the results of this study, it can be stated that level IV protection of LPS is needed and multiply the number of lightning protection rods where a minimum of 4 rods for 1 building roof