{"title":"茜素红 S 作为致色剂测定药物制剂中的美罗培南","authors":"Wallada H. Ibrahim, Hana Mahmood","doi":"10.33899/rjs.2024.182833","DOIUrl":null,"url":null,"abstract":"Alizarin red S (ALRS)reagent has been used for to determination of meropenem (MEP)by an easy, sensitive, and selective procedure based on an ion-pair formation reaction between ALRS and MEP in an aqueous: alcoholic medium in the ratio of 50:50 without adjustment of the acidity of the reaction medium. The linearity ranged from 1 to 50 µg /mL, molar absorptivity was 6.557 × 10 3 L.mol -1 .cm -1 ., index of Sandell’s, was 585584 µg.cm -2 , and the calculated LOD and LOQ were 0.02789 µg/mL, 0.0929 µg/mL respectively. The calculated range of relative error was from -1.022 to 0.34 % which indicates high accuracy, and the calculated range of the relative standard deviation was from 0.347 to 0.574% which indicates high precision. The method has been applied for the determination of MEP in dosage forms successfully in which the recovery ranged from 99.8 to 103.2%. The standard addition method proves no interfering effect caused by inactive ingredients involved in dosage forms of meropenem","PeriodicalId":20803,"journal":{"name":"Rafidain journal of science","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Alizarin Red S as a Chromogenic Agent for the Determination of Meropenem in Pharmaceutical- Formulations\",\"authors\":\"Wallada H. Ibrahim, Hana Mahmood\",\"doi\":\"10.33899/rjs.2024.182833\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Alizarin red S (ALRS)reagent has been used for to determination of meropenem (MEP)by an easy, sensitive, and selective procedure based on an ion-pair formation reaction between ALRS and MEP in an aqueous: alcoholic medium in the ratio of 50:50 without adjustment of the acidity of the reaction medium. The linearity ranged from 1 to 50 µg /mL, molar absorptivity was 6.557 × 10 3 L.mol -1 .cm -1 ., index of Sandell’s, was 585584 µg.cm -2 , and the calculated LOD and LOQ were 0.02789 µg/mL, 0.0929 µg/mL respectively. The calculated range of relative error was from -1.022 to 0.34 % which indicates high accuracy, and the calculated range of the relative standard deviation was from 0.347 to 0.574% which indicates high precision. The method has been applied for the determination of MEP in dosage forms successfully in which the recovery ranged from 99.8 to 103.2%. The standard addition method proves no interfering effect caused by inactive ingredients involved in dosage forms of meropenem\",\"PeriodicalId\":20803,\"journal\":{\"name\":\"Rafidain journal of science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Rafidain journal of science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.33899/rjs.2024.182833\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rafidain journal of science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.33899/rjs.2024.182833","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Alizarin Red S as a Chromogenic Agent for the Determination of Meropenem in Pharmaceutical- Formulations
Alizarin red S (ALRS)reagent has been used for to determination of meropenem (MEP)by an easy, sensitive, and selective procedure based on an ion-pair formation reaction between ALRS and MEP in an aqueous: alcoholic medium in the ratio of 50:50 without adjustment of the acidity of the reaction medium. The linearity ranged from 1 to 50 µg /mL, molar absorptivity was 6.557 × 10 3 L.mol -1 .cm -1 ., index of Sandell’s, was 585584 µg.cm -2 , and the calculated LOD and LOQ were 0.02789 µg/mL, 0.0929 µg/mL respectively. The calculated range of relative error was from -1.022 to 0.34 % which indicates high accuracy, and the calculated range of the relative standard deviation was from 0.347 to 0.574% which indicates high precision. The method has been applied for the determination of MEP in dosage forms successfully in which the recovery ranged from 99.8 to 103.2%. The standard addition method proves no interfering effect caused by inactive ingredients involved in dosage forms of meropenem