Nada A Helal, Marilyn N Martinez, David G Longstaff, Ziyaur Rahman, Mohammad T H Nutan, Mansoor A Khan
{"title":"开发和验证用于乳内药物产品 (IMM) 的化学、制造和控制矩阵 (MoCMC) 系统。","authors":"Nada A Helal, Marilyn N Martinez, David G Longstaff, Ziyaur Rahman, Mohammad T H Nutan, Mansoor A Khan","doi":"10.1007/s11095-024-03689-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Products formulated for intramammary (IMM) infusion are intended for the delivery of therapeutic moieties directly into the udder through the teat canal to maximize drug exposure at the targeted clinical site, the mammary gland, with little to no systemic drug exposure. Currently, to our knowledge, there has been no in-vitro matrix system available to differentiate between IMM formulations. Our goal is to develop A custom tailored in-vitro \"Matrix of Chemistry, Manufacturing and Control\" (MoCMC) System to be a promising future tool for identifying inequivalent IMM formulations. MoCMC can detect inter and intra batch variabilities, thereby identifying potential generics versus brand product similarities or differences with a single numeric value and a specific & distinctive fingerprint.</p><p><strong>Methods: </strong>The FDA-approved IMM formulation, SPECTRAMAST<sup>Ⓡ</sup> LC, was selected as the reference product for the MoCMC. Twelve in-house test formulations containing ceftiofur hydrochloride were formulated and characterized. The MoCMC was developed to include six input parameters and three output parameters. The MoCMC system was used to evaluate and compare SPECTRAMAST<sup>Ⓡ</sup> LC with its in-house formulations.</p><p><strong>Results: </strong>Based on the MoCMC generated parameters, the distinctive fingerprints of MoCMC for each IMM formulations, and the statistical analyses of MCI and PPI values, in-house formulations, F-01 and F-02 showed consistency while the rest of in-house formulations (F-03-F-12) were significantly different as compared to SPECTRAMAST<sup>Ⓡ</sup> LC.</p><p><strong>Conclusion: </strong>This research showed that the MoCMC approach can be used as a tool for intra batch variabilities, generics versus brand products comparisons, post-approval formulations changes, manufacturing changes, and formulation variabilities.</p>","PeriodicalId":20027,"journal":{"name":"Pharmaceutical Research","volume":" ","pages":"1007-1020"},"PeriodicalIF":3.5000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development and Validation of Matrix of Chemistry, Manufacturing, and Control (MoCMC) System for Intramammary Drug Products (IMM).\",\"authors\":\"Nada A Helal, Marilyn N Martinez, David G Longstaff, Ziyaur Rahman, Mohammad T H Nutan, Mansoor A Khan\",\"doi\":\"10.1007/s11095-024-03689-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Products formulated for intramammary (IMM) infusion are intended for the delivery of therapeutic moieties directly into the udder through the teat canal to maximize drug exposure at the targeted clinical site, the mammary gland, with little to no systemic drug exposure. Currently, to our knowledge, there has been no in-vitro matrix system available to differentiate between IMM formulations. Our goal is to develop A custom tailored in-vitro \\\"Matrix of Chemistry, Manufacturing and Control\\\" (MoCMC) System to be a promising future tool for identifying inequivalent IMM formulations. MoCMC can detect inter and intra batch variabilities, thereby identifying potential generics versus brand product similarities or differences with a single numeric value and a specific & distinctive fingerprint.</p><p><strong>Methods: </strong>The FDA-approved IMM formulation, SPECTRAMAST<sup>Ⓡ</sup> LC, was selected as the reference product for the MoCMC. Twelve in-house test formulations containing ceftiofur hydrochloride were formulated and characterized. The MoCMC was developed to include six input parameters and three output parameters. The MoCMC system was used to evaluate and compare SPECTRAMAST<sup>Ⓡ</sup> LC with its in-house formulations.</p><p><strong>Results: </strong>Based on the MoCMC generated parameters, the distinctive fingerprints of MoCMC for each IMM formulations, and the statistical analyses of MCI and PPI values, in-house formulations, F-01 and F-02 showed consistency while the rest of in-house formulations (F-03-F-12) were significantly different as compared to SPECTRAMAST<sup>Ⓡ</sup> LC.</p><p><strong>Conclusion: </strong>This research showed that the MoCMC approach can be used as a tool for intra batch variabilities, generics versus brand products comparisons, post-approval formulations changes, manufacturing changes, and formulation variabilities.</p>\",\"PeriodicalId\":20027,\"journal\":{\"name\":\"Pharmaceutical Research\",\"volume\":\" \",\"pages\":\"1007-1020\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pharmaceutical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s11095-024-03689-z\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/4/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pharmaceutical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s11095-024-03689-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/1 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Development and Validation of Matrix of Chemistry, Manufacturing, and Control (MoCMC) System for Intramammary Drug Products (IMM).
Purpose: Products formulated for intramammary (IMM) infusion are intended for the delivery of therapeutic moieties directly into the udder through the teat canal to maximize drug exposure at the targeted clinical site, the mammary gland, with little to no systemic drug exposure. Currently, to our knowledge, there has been no in-vitro matrix system available to differentiate between IMM formulations. Our goal is to develop A custom tailored in-vitro "Matrix of Chemistry, Manufacturing and Control" (MoCMC) System to be a promising future tool for identifying inequivalent IMM formulations. MoCMC can detect inter and intra batch variabilities, thereby identifying potential generics versus brand product similarities or differences with a single numeric value and a specific & distinctive fingerprint.
Methods: The FDA-approved IMM formulation, SPECTRAMASTⓇ LC, was selected as the reference product for the MoCMC. Twelve in-house test formulations containing ceftiofur hydrochloride were formulated and characterized. The MoCMC was developed to include six input parameters and three output parameters. The MoCMC system was used to evaluate and compare SPECTRAMASTⓇ LC with its in-house formulations.
Results: Based on the MoCMC generated parameters, the distinctive fingerprints of MoCMC for each IMM formulations, and the statistical analyses of MCI and PPI values, in-house formulations, F-01 and F-02 showed consistency while the rest of in-house formulations (F-03-F-12) were significantly different as compared to SPECTRAMASTⓇ LC.
Conclusion: This research showed that the MoCMC approach can be used as a tool for intra batch variabilities, generics versus brand products comparisons, post-approval formulations changes, manufacturing changes, and formulation variabilities.
期刊介绍:
Pharmaceutical Research, an official journal of the American Association of Pharmaceutical Scientists, is committed to publishing novel research that is mechanism-based, hypothesis-driven and addresses significant issues in drug discovery, development and regulation. Current areas of interest include, but are not limited to:
-(pre)formulation engineering and processing-
computational biopharmaceutics-
drug delivery and targeting-
molecular biopharmaceutics and drug disposition (including cellular and molecular pharmacology)-
pharmacokinetics, pharmacodynamics and pharmacogenetics.
Research may involve nonclinical and clinical studies, and utilize both in vitro and in vivo approaches. Studies on small drug molecules, pharmaceutical solid materials (including biomaterials, polymers and nanoparticles) biotechnology products (including genes, peptides, proteins and vaccines), and genetically engineered cells are welcome.