A Elbahi, O Thomas, M Dungey, C Randall, D K Menon
{"title":"股骨近端骨折固定术中辐照增加的相关因素。","authors":"A Elbahi, O Thomas, M Dungey, C Randall, D K Menon","doi":"10.1308/rcsann.2023.0092","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>When using radiation intraoperatively, a surgeon should aim to keep the radiation dose as low as is reasonably achievable to obtain the therapeutic goal. We aimed to investigate factors associated with increased radiation exposure in fixation of proximal femur fractures.</p><p><strong>Methods: </strong>We assessed 369 neck of femur fractures over a 1-year period in a district general hospital. All hip fracture subtypes that had undergone surgical fixation were included. We assessed the relationship between type of fracture, implants used and surgeon level of experience with the dose-area product (DAP; cGy/cm<sup>2</sup>) and screening time (dS). We also looked at the quality of reduction and fixation and its effect on the radiation exposure.</p><p><strong>Results: </strong>A total of 184 patients were included in our analysis; 185 patients who were treated with hip arthroplasty were excluded. There was a significant association between higher DAP and fracture subtype (<i>p</i> = 0.001), fracture complexity (<i>p</i> < 0.001), if an additional implant was used (<i>p</i> = 0.001), if fixation was satisfactory (<i>p</i> = 0.002) and operative time (<i>p</i> < 0.001). DAP was higher with a proximal femoral nail than with a dynamic hip screw, especially when a long nail was used. There was some evidence of an association between the surgeon's level of experience and DAP exposure, although this was not statistically significant (<i>p</i> = 0.069).</p><p><strong>Conclusions: </strong>Increased radiation in proximal femur fractures is seen in the fixation of complex fractures, some subtypes, with certain types of implants used and if an additional implant was required. Surgeon seniority did not result in less radiation exposure, which is in contrast to other published studies.</p>","PeriodicalId":8088,"journal":{"name":"Annals of the Royal College of Surgeons of England","volume":" ","pages":"41-47"},"PeriodicalIF":1.1000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11658882/pdf/","citationCount":"0","resultStr":"{\"title\":\"Factors associated with increased radiation exposure in the fixation of proximal femoral fractures.\",\"authors\":\"A Elbahi, O Thomas, M Dungey, C Randall, D K Menon\",\"doi\":\"10.1308/rcsann.2023.0092\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>When using radiation intraoperatively, a surgeon should aim to keep the radiation dose as low as is reasonably achievable to obtain the therapeutic goal. We aimed to investigate factors associated with increased radiation exposure in fixation of proximal femur fractures.</p><p><strong>Methods: </strong>We assessed 369 neck of femur fractures over a 1-year period in a district general hospital. All hip fracture subtypes that had undergone surgical fixation were included. We assessed the relationship between type of fracture, implants used and surgeon level of experience with the dose-area product (DAP; cGy/cm<sup>2</sup>) and screening time (dS). We also looked at the quality of reduction and fixation and its effect on the radiation exposure.</p><p><strong>Results: </strong>A total of 184 patients were included in our analysis; 185 patients who were treated with hip arthroplasty were excluded. There was a significant association between higher DAP and fracture subtype (<i>p</i> = 0.001), fracture complexity (<i>p</i> < 0.001), if an additional implant was used (<i>p</i> = 0.001), if fixation was satisfactory (<i>p</i> = 0.002) and operative time (<i>p</i> < 0.001). DAP was higher with a proximal femoral nail than with a dynamic hip screw, especially when a long nail was used. There was some evidence of an association between the surgeon's level of experience and DAP exposure, although this was not statistically significant (<i>p</i> = 0.069).</p><p><strong>Conclusions: </strong>Increased radiation in proximal femur fractures is seen in the fixation of complex fractures, some subtypes, with certain types of implants used and if an additional implant was required. Surgeon seniority did not result in less radiation exposure, which is in contrast to other published studies.</p>\",\"PeriodicalId\":8088,\"journal\":{\"name\":\"Annals of the Royal College of Surgeons of England\",\"volume\":\" \",\"pages\":\"41-47\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11658882/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of the Royal College of Surgeons of England\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1308/rcsann.2023.0092\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/4/2 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of the Royal College of Surgeons of England","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1308/rcsann.2023.0092","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/4/2 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
Factors associated with increased radiation exposure in the fixation of proximal femoral fractures.
Introduction: When using radiation intraoperatively, a surgeon should aim to keep the radiation dose as low as is reasonably achievable to obtain the therapeutic goal. We aimed to investigate factors associated with increased radiation exposure in fixation of proximal femur fractures.
Methods: We assessed 369 neck of femur fractures over a 1-year period in a district general hospital. All hip fracture subtypes that had undergone surgical fixation were included. We assessed the relationship between type of fracture, implants used and surgeon level of experience with the dose-area product (DAP; cGy/cm2) and screening time (dS). We also looked at the quality of reduction and fixation and its effect on the radiation exposure.
Results: A total of 184 patients were included in our analysis; 185 patients who were treated with hip arthroplasty were excluded. There was a significant association between higher DAP and fracture subtype (p = 0.001), fracture complexity (p < 0.001), if an additional implant was used (p = 0.001), if fixation was satisfactory (p = 0.002) and operative time (p < 0.001). DAP was higher with a proximal femoral nail than with a dynamic hip screw, especially when a long nail was used. There was some evidence of an association between the surgeon's level of experience and DAP exposure, although this was not statistically significant (p = 0.069).
Conclusions: Increased radiation in proximal femur fractures is seen in the fixation of complex fractures, some subtypes, with certain types of implants used and if an additional implant was required. Surgeon seniority did not result in less radiation exposure, which is in contrast to other published studies.
期刊介绍:
The Annals of The Royal College of Surgeons of England is the official scholarly research journal of the Royal College of Surgeons and is published eight times a year in January, February, March, April, May, July, September and November.
The main aim of the journal is to publish high-quality, peer-reviewed papers that relate to all branches of surgery. The Annals also includes letters and comments, a regular technical section, controversial topics, CORESS feedback and book reviews. The editorial board is composed of experts from all the surgical specialties.