{"title":"使用 GoreTex 缝合线固定小切口新一代植入式微型望远镜(SING IMT ™)的巩膜。","authors":"Alfonso Savastano, Leonardo Andrea Sammarco, Giuseppe Francione, Paola Sasso, Stanislao Rizzo","doi":"10.1097/ICB.0000000000001572","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>In this case report, the authors describe a surgical technique for scleral fixation of the smaller-incision new-generation implantable miniature telescope (SING-IMT). Using this surgical technique, the patient's eye that undergoes surgery for the SING-IMT could still have a safe SING IMT implant despite the anatomical conditions of the capsular bag or in cases of intraoperative complications.</p><p><strong>Methods: </strong>The surgery was performed at Policlinico A. Gemelli, Rome, Italy. The patient's eye underwent a first surgery for an artificial intraocular lens explant and SING-IMT implant at the same time. The authors observed SING IMT dislocation into the vitreous chamber 90 days after surgery. Therefore, they carried out a 23-gauge vitrectomy, and after SING IMT recovery from the vitreous chamber, they fixed one of its haptic to the sclera using an 8.0 Gore-Tex suture.</p><p><strong>Conclusion: </strong>Scleral fixation of SING-IMT haptics might be useful in eyes with dislocated or not stable SING IMT. The authors believe that reporting our experience can help surgeons fix SING IMT in complicated cases where a capsular bag rupture or disinsertion (like our case) can cause SING IMT decentration or worse its drop into the vitreous chamber. They speculate that the Gore-Tex suture could assure firm fixation of the SING IMT and could reduce the risk of recurrent dislocations.</p>","PeriodicalId":53580,"journal":{"name":"Retinal Cases and Brief Reports","volume":" ","pages":"410-412"},"PeriodicalIF":0.0000,"publicationDate":"2025-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"SCLERAL FIXATION OF THE SMALLER-INCISION NEW-GENERATION IMPLANTABLE MINIATURE TELESCOPE USING GORE-TEX SUTURE.\",\"authors\":\"Alfonso Savastano, Leonardo Andrea Sammarco, Giuseppe Francione, Paola Sasso, Stanislao Rizzo\",\"doi\":\"10.1097/ICB.0000000000001572\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>In this case report, the authors describe a surgical technique for scleral fixation of the smaller-incision new-generation implantable miniature telescope (SING-IMT). Using this surgical technique, the patient's eye that undergoes surgery for the SING-IMT could still have a safe SING IMT implant despite the anatomical conditions of the capsular bag or in cases of intraoperative complications.</p><p><strong>Methods: </strong>The surgery was performed at Policlinico A. Gemelli, Rome, Italy. The patient's eye underwent a first surgery for an artificial intraocular lens explant and SING-IMT implant at the same time. The authors observed SING IMT dislocation into the vitreous chamber 90 days after surgery. Therefore, they carried out a 23-gauge vitrectomy, and after SING IMT recovery from the vitreous chamber, they fixed one of its haptic to the sclera using an 8.0 Gore-Tex suture.</p><p><strong>Conclusion: </strong>Scleral fixation of SING-IMT haptics might be useful in eyes with dislocated or not stable SING IMT. The authors believe that reporting our experience can help surgeons fix SING IMT in complicated cases where a capsular bag rupture or disinsertion (like our case) can cause SING IMT decentration or worse its drop into the vitreous chamber. They speculate that the Gore-Tex suture could assure firm fixation of the SING IMT and could reduce the risk of recurrent dislocations.</p>\",\"PeriodicalId\":53580,\"journal\":{\"name\":\"Retinal Cases and Brief Reports\",\"volume\":\" \",\"pages\":\"410-412\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2025-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Retinal Cases and Brief Reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/ICB.0000000000001572\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Retinal Cases and Brief Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/ICB.0000000000001572","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:在这篇病例报告中,我们介绍了一种用于小切口新一代植入式微型望远镜(SING-IMT)巩膜固定的手术技术。利用这种手术技术,接受 SING-IMT 手术的患者眼球在囊袋解剖条件不佳或术中出现并发症的情况下,仍能安全地植入 SING IMT:手术在意大利罗马的 Policlinico A. Gemelli 进行。患者的眼睛同时接受了人工晶体摘除和 SING-IMT 植入的首次手术。术后 90 天,我们观察到 SING IMT 脱位进入玻璃体腔。因此,我们进行了23号玻璃体切除术,并在SING-IMT从玻璃体腔中恢复后,用8.0 GoreTex缝合线将其一个触点固定在巩膜上:结论:巩膜固定 SING-IMT 触点可能对脱位或不稳定的 SING IMT 眼有用。我们相信,报告我们的经验可以帮助外科医生在囊袋破裂或脱出(如我们的病例)可能导致 SING IMT 脱位或掉入玻璃体腔的复杂病例中固定 SING IMT。我们推测,GoreTex 缝合线可确保 SING IMT 的牢固固定,并可降低复发脱位的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
SCLERAL FIXATION OF THE SMALLER-INCISION NEW-GENERATION IMPLANTABLE MINIATURE TELESCOPE USING GORE-TEX SUTURE.

Purpose: In this case report, the authors describe a surgical technique for scleral fixation of the smaller-incision new-generation implantable miniature telescope (SING-IMT). Using this surgical technique, the patient's eye that undergoes surgery for the SING-IMT could still have a safe SING IMT implant despite the anatomical conditions of the capsular bag or in cases of intraoperative complications.

Methods: The surgery was performed at Policlinico A. Gemelli, Rome, Italy. The patient's eye underwent a first surgery for an artificial intraocular lens explant and SING-IMT implant at the same time. The authors observed SING IMT dislocation into the vitreous chamber 90 days after surgery. Therefore, they carried out a 23-gauge vitrectomy, and after SING IMT recovery from the vitreous chamber, they fixed one of its haptic to the sclera using an 8.0 Gore-Tex suture.

Conclusion: Scleral fixation of SING-IMT haptics might be useful in eyes with dislocated or not stable SING IMT. The authors believe that reporting our experience can help surgeons fix SING IMT in complicated cases where a capsular bag rupture or disinsertion (like our case) can cause SING IMT decentration or worse its drop into the vitreous chamber. They speculate that the Gore-Tex suture could assure firm fixation of the SING IMT and could reduce the risk of recurrent dislocations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Retinal Cases and Brief Reports
Retinal Cases and Brief Reports Medicine-Ophthalmology
CiteScore
2.10
自引率
0.00%
发文量
342
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信