经导管主动脉瓣植入术后压力-容积环路分析对机械效率的急性影响

IF 1.8 4区 医学 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Shen-Che Lin, Chih-Yao Chiang, Jung-Cheng Hsu, Jih-Hsin Huang, Jer-Shen Chen, Kuan-Ming Chiu
{"title":"经导管主动脉瓣植入术后压力-容积环路分析对机械效率的急性影响","authors":"Shen-Che Lin, Chih-Yao Chiang, Jung-Cheng Hsu, Jih-Hsin Huang, Jer-Shen Chen, Kuan-Ming Chiu","doi":"10.6515/ACS.202403_40(2).20231230A","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to evaluate the immediate effect of transcatheter aortic valve implantation (TAVI) on mechanical efficiency.</p><p><strong>Methods: </strong>A total of 46 patients (25 females) with an average age of 83 ± 6.4 years underwent TAVI using the CoreValve system. During the same hospitalization, we conducted a comprehensive comparison of the patients before and after TAVI without inotropic support using echocardiography. The parameters encompassed left ventricular (LV) geometry, valvular load, global LV afterload and ventricular hemodynamics. The analysis using pressure-volume loops enabled the determination of load-independent contractility (Ees) and afterload, in addition to assessing potential energy, stroke work, and mechanical efficiency.</p><p><strong>Results: </strong>The immediate effect was an augmented aortic valve area accompanied by a reduction in the transvalvular pressure gradient. We observed reductions in left ventricular end-systolic volume and end-diastolic volume, and also reductions in global afterload and end-systolic meridional wall stress. The Ea index decreased, while the Ees index remained relatively stable. We noted increases in stroke volume and systemic arterial compliance, indicating more efficient blood transfer from the ventricle to aorta. These changes contributed to the normalization of ventricular-arterial coupling. In terms of mechanical work of the chamber, we observed significant decreases in potential energy, stroke work, and pressure-volume area. There was an increase in the mechanical efficiency of the chamber.</p><p><strong>Conclusions: </strong>The TAVI procedure immediately reduced global afterload and improved diastolic compliance of the chamber, resulting in enhanced ventricular function and mechanical efficiency.</p>","PeriodicalId":6957,"journal":{"name":"Acta Cardiologica Sinica","volume":"40 2","pages":"242-252"},"PeriodicalIF":1.8000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10961641/pdf/","citationCount":"0","resultStr":"{\"title\":\"Acute Effect in Mechanical Efficiency by Pressure-Volume Loop Analysis after Transcatheter Aortic Valve Implantation.\",\"authors\":\"Shen-Che Lin, Chih-Yao Chiang, Jung-Cheng Hsu, Jih-Hsin Huang, Jer-Shen Chen, Kuan-Ming Chiu\",\"doi\":\"10.6515/ACS.202403_40(2).20231230A\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>This study aimed to evaluate the immediate effect of transcatheter aortic valve implantation (TAVI) on mechanical efficiency.</p><p><strong>Methods: </strong>A total of 46 patients (25 females) with an average age of 83 ± 6.4 years underwent TAVI using the CoreValve system. During the same hospitalization, we conducted a comprehensive comparison of the patients before and after TAVI without inotropic support using echocardiography. The parameters encompassed left ventricular (LV) geometry, valvular load, global LV afterload and ventricular hemodynamics. The analysis using pressure-volume loops enabled the determination of load-independent contractility (Ees) and afterload, in addition to assessing potential energy, stroke work, and mechanical efficiency.</p><p><strong>Results: </strong>The immediate effect was an augmented aortic valve area accompanied by a reduction in the transvalvular pressure gradient. We observed reductions in left ventricular end-systolic volume and end-diastolic volume, and also reductions in global afterload and end-systolic meridional wall stress. The Ea index decreased, while the Ees index remained relatively stable. We noted increases in stroke volume and systemic arterial compliance, indicating more efficient blood transfer from the ventricle to aorta. These changes contributed to the normalization of ventricular-arterial coupling. In terms of mechanical work of the chamber, we observed significant decreases in potential energy, stroke work, and pressure-volume area. There was an increase in the mechanical efficiency of the chamber.</p><p><strong>Conclusions: </strong>The TAVI procedure immediately reduced global afterload and improved diastolic compliance of the chamber, resulting in enhanced ventricular function and mechanical efficiency.</p>\",\"PeriodicalId\":6957,\"journal\":{\"name\":\"Acta Cardiologica Sinica\",\"volume\":\"40 2\",\"pages\":\"242-252\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10961641/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta Cardiologica Sinica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.6515/ACS.202403_40(2).20231230A\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Cardiologica Sinica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.6515/ACS.202403_40(2).20231230A","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景本研究旨在评估经导管主动脉瓣植入术(TAVI)对机械效率的直接影响:共有 46 名患者(25 名女性)接受了使用 CoreValve 系统的 TAVI 手术,平均年龄为 83 ± 6.4 岁。在同一住院期间,我们使用超声心动图对患者在无肌力支持的情况下进行 TAVI 手术前后进行了全面比较。参数包括左心室(LV)几何形状、瓣膜负荷、整体左心室后负荷和心室血流动力学。通过压力-容积环路分析,除了评估势能、每搏功和机械效率外,还能确定与负荷无关的收缩力(Ees)和后负荷:直接效果是主动脉瓣面积增大,跨瓣压力梯度降低。我们观察到左心室收缩末期容积和舒张末期容积缩小,总体后负荷和收缩末期经室壁应力降低。Ea 指数下降,而 Ees 指数保持相对稳定。我们注意到每搏量和全身动脉顺应性增加,这表明从心室到主动脉的血液传输更加有效。这些变化有助于心室-动脉耦合的正常化。在心腔的机械功方面,我们观察到势能、冲程功和压力-容积面积显著下降。结论:结论:TAVI手术立即减轻了整体后负荷,改善了心腔的舒张顺应性,从而增强了心室功能和机械效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Acute Effect in Mechanical Efficiency by Pressure-Volume Loop Analysis after Transcatheter Aortic Valve Implantation.

Background: This study aimed to evaluate the immediate effect of transcatheter aortic valve implantation (TAVI) on mechanical efficiency.

Methods: A total of 46 patients (25 females) with an average age of 83 ± 6.4 years underwent TAVI using the CoreValve system. During the same hospitalization, we conducted a comprehensive comparison of the patients before and after TAVI without inotropic support using echocardiography. The parameters encompassed left ventricular (LV) geometry, valvular load, global LV afterload and ventricular hemodynamics. The analysis using pressure-volume loops enabled the determination of load-independent contractility (Ees) and afterload, in addition to assessing potential energy, stroke work, and mechanical efficiency.

Results: The immediate effect was an augmented aortic valve area accompanied by a reduction in the transvalvular pressure gradient. We observed reductions in left ventricular end-systolic volume and end-diastolic volume, and also reductions in global afterload and end-systolic meridional wall stress. The Ea index decreased, while the Ees index remained relatively stable. We noted increases in stroke volume and systemic arterial compliance, indicating more efficient blood transfer from the ventricle to aorta. These changes contributed to the normalization of ventricular-arterial coupling. In terms of mechanical work of the chamber, we observed significant decreases in potential energy, stroke work, and pressure-volume area. There was an increase in the mechanical efficiency of the chamber.

Conclusions: The TAVI procedure immediately reduced global afterload and improved diastolic compliance of the chamber, resulting in enhanced ventricular function and mechanical efficiency.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta Cardiologica Sinica
Acta Cardiologica Sinica 医学-心血管系统
CiteScore
2.90
自引率
15.80%
发文量
144
审稿时长
>12 weeks
期刊介绍: Acta Cardiologica Sinica welcomes all the papers in the fields related to cardiovascular medicine including basic research, vascular biology, clinical pharmacology, clinical trial, critical care medicine, coronary artery disease, interventional cardiology, arrythmia and electrophysiology, atherosclerosis, hypertension, cardiomyopathy and heart failure, valvular and structure cardiac disease, pediatric cardiology, cardiovascular surgery, and so on. We received papers from more than 20 countries and areas of the world. Currently, 40% of the papers were submitted to Acta Cardiologica Sinica from Taiwan, 20% from China, and 20% from the other countries and areas in the world. The acceptance rate for publication was around 50% in general.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信