通过瞬态弹性成像测定的肝脏硬度是临床上预测肝硬化存在与否的一个简单而又高度准确的指标。

IF 2 4区 医学 Q3 GASTROENTEROLOGY & HEPATOLOGY
Digestive Diseases Pub Date : 2024-01-01 Epub Date: 2024-03-25 DOI:10.1159/000538426
Peter Lemmer, Lydia Christina Rohr, Marie Henning, Kerem Bulut, Paul Manka, Ali Canbay, Jan-Peter Sowa
{"title":"通过瞬态弹性成像测定的肝脏硬度是临床上预测肝硬化存在与否的一个简单而又高度准确的指标。","authors":"Peter Lemmer, Lydia Christina Rohr, Marie Henning, Kerem Bulut, Paul Manka, Ali Canbay, Jan-Peter Sowa","doi":"10.1159/000538426","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Early detection of patients with advanced chronic liver disease is critical for the prevention of complications and inclusion in surveillance programs for hepatocellular carcinoma. In daily clinical care, it remains challenging to differentiate early cirrhosis from lower fibrosis grades without performing a liver biopsy. The aim of the present study was to assess the performance of different non-invasive detection tools to differentiate cirrhosis from lower fibrosis grades.</p><p><strong>Methods: </strong>Data of 116 patients (51 male, 65 female) with chronic liver disease of various origins undergoing liver biopsy was analyzed. Routine laboratory values, liver stiffness measurement (LSM) by transient elastography, and histological liver assessment were collected.</p><p><strong>Results: </strong>Robust and significant correlations with the histological fibrosis stage were identified for LSM (r = 0.65), the FAST score (0.64), the FIB-4 (0.48), serum aspartate aminotransferase (AST) concentration (0.41), NFS (0.33), international normalized ratio (INR; 0.30), methacetin breath test results (-0.40), and serum albumin concentration (-0.29) by spearman rank correlation. Receiver operating characteristic curves were built for these parameters to separate patients with cirrhosis from those with any other fibrosis stage. The highest AUC was achieved by LSM (0.9130), followed by the FAST score (0.8842), the FIB-4 (0.8644), the NFS (0.8227), INR (0.8142), serum albumin (0.7710), and serum AST (0.7620). The most promising clinical applicability would be an LSM value of 12.2 kPa, achieving 95.7% sensitivity and 75.3% specificity.</p><p><strong>Conclusion: </strong>LSM and FAST score seem to be robust non-invasive measurements for liver fibrosis. LSM and FAST scores may have the potential to reliably detect patients with liver cirrhosis in clinical routine settings.</p>","PeriodicalId":11294,"journal":{"name":"Digestive Diseases","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Liver Stiffness Determined by Transient Elastography Is a Simple and Highly Accurate Predictor for Presence of Liver Cirrhosis in Clinical Routine.\",\"authors\":\"Peter Lemmer, Lydia Christina Rohr, Marie Henning, Kerem Bulut, Paul Manka, Ali Canbay, Jan-Peter Sowa\",\"doi\":\"10.1159/000538426\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Early detection of patients with advanced chronic liver disease is critical for the prevention of complications and inclusion in surveillance programs for hepatocellular carcinoma. In daily clinical care, it remains challenging to differentiate early cirrhosis from lower fibrosis grades without performing a liver biopsy. The aim of the present study was to assess the performance of different non-invasive detection tools to differentiate cirrhosis from lower fibrosis grades.</p><p><strong>Methods: </strong>Data of 116 patients (51 male, 65 female) with chronic liver disease of various origins undergoing liver biopsy was analyzed. Routine laboratory values, liver stiffness measurement (LSM) by transient elastography, and histological liver assessment were collected.</p><p><strong>Results: </strong>Robust and significant correlations with the histological fibrosis stage were identified for LSM (r = 0.65), the FAST score (0.64), the FIB-4 (0.48), serum aspartate aminotransferase (AST) concentration (0.41), NFS (0.33), international normalized ratio (INR; 0.30), methacetin breath test results (-0.40), and serum albumin concentration (-0.29) by spearman rank correlation. Receiver operating characteristic curves were built for these parameters to separate patients with cirrhosis from those with any other fibrosis stage. The highest AUC was achieved by LSM (0.9130), followed by the FAST score (0.8842), the FIB-4 (0.8644), the NFS (0.8227), INR (0.8142), serum albumin (0.7710), and serum AST (0.7620). The most promising clinical applicability would be an LSM value of 12.2 kPa, achieving 95.7% sensitivity and 75.3% specificity.</p><p><strong>Conclusion: </strong>LSM and FAST score seem to be robust non-invasive measurements for liver fibrosis. LSM and FAST scores may have the potential to reliably detect patients with liver cirrhosis in clinical routine settings.</p>\",\"PeriodicalId\":11294,\"journal\":{\"name\":\"Digestive Diseases\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Digestive Diseases\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1159/000538426\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"GASTROENTEROLOGY & HEPATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Digestive Diseases","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000538426","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

导言:早期发现晚期慢性肝病患者对于预防并发症和纳入肝细胞癌监测计划至关重要。在日常临床护理中,不进行肝脏活检而区分早期肝硬化和较低纤维化等级仍具有挑战性。本研究旨在评估不同无创检测工具在区分肝硬化和较低纤维化等级方面的性能:分析了 116 名接受肝活检的不同原因慢性肝病患者(51 名男性,65 名女性)的数据。收集了常规实验室值、通过瞬态弹性成像进行的肝脏硬度测量(LSM)以及肝脏组织学评估结果:结果:通过矛曼秩相关性分析发现,LSM(r=0.65)、FAST评分(0.64)、FIB-4(0.48)、血清谷草转氨酶浓度(0.41)、NFS(0.33)、INR(0.30)、甲乙酰呼气试验结果(-0.40)和血清白蛋白浓度(-0.29)与组织学纤维化分期存在稳健且重要的相关性。针对这些参数建立了 ROC 曲线,以区分肝硬化患者和其他任何纤维化阶段的患者。LSM的AUC最高(0.9130),其次是FAST评分(0.8842)、FIB-4(0.8644)、NFS(0.8227)、INR(0.8142)、血清白蛋白(0.7710)和血清谷草转氨酶(0.7620)。最有希望应用于临床的 LSM 值为 12.2 kPa,灵敏度为 95.7%,特异性为 75.3%:结论:LSM 和 FAST 评分似乎是可靠的肝纤维化无创测量方法。结论:LSM 和 FAST 评分似乎是一种可靠的肝纤维化无创测量方法,LSM 和 FAST 评分可能具有在临床常规环境中可靠检测肝硬化患者的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Liver Stiffness Determined by Transient Elastography Is a Simple and Highly Accurate Predictor for Presence of Liver Cirrhosis in Clinical Routine.

Introduction: Early detection of patients with advanced chronic liver disease is critical for the prevention of complications and inclusion in surveillance programs for hepatocellular carcinoma. In daily clinical care, it remains challenging to differentiate early cirrhosis from lower fibrosis grades without performing a liver biopsy. The aim of the present study was to assess the performance of different non-invasive detection tools to differentiate cirrhosis from lower fibrosis grades.

Methods: Data of 116 patients (51 male, 65 female) with chronic liver disease of various origins undergoing liver biopsy was analyzed. Routine laboratory values, liver stiffness measurement (LSM) by transient elastography, and histological liver assessment were collected.

Results: Robust and significant correlations with the histological fibrosis stage were identified for LSM (r = 0.65), the FAST score (0.64), the FIB-4 (0.48), serum aspartate aminotransferase (AST) concentration (0.41), NFS (0.33), international normalized ratio (INR; 0.30), methacetin breath test results (-0.40), and serum albumin concentration (-0.29) by spearman rank correlation. Receiver operating characteristic curves were built for these parameters to separate patients with cirrhosis from those with any other fibrosis stage. The highest AUC was achieved by LSM (0.9130), followed by the FAST score (0.8842), the FIB-4 (0.8644), the NFS (0.8227), INR (0.8142), serum albumin (0.7710), and serum AST (0.7620). The most promising clinical applicability would be an LSM value of 12.2 kPa, achieving 95.7% sensitivity and 75.3% specificity.

Conclusion: LSM and FAST score seem to be robust non-invasive measurements for liver fibrosis. LSM and FAST scores may have the potential to reliably detect patients with liver cirrhosis in clinical routine settings.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Digestive Diseases
Digestive Diseases 医学-胃肠肝病学
CiteScore
4.80
自引率
0.00%
发文量
58
审稿时长
2 months
期刊介绍: Each issue of this journal is dedicated to a special topic of current interest, covering both clinical and basic science topics in gastrointestinal function and disorders. The contents of each issue are comprehensive and reflect the state of the art, featuring editorials, reviews, mini reviews and original papers. These individual contributions encompass a variety of disciplines including all fields of gastroenterology. ''Digestive Diseases'' bridges the communication gap between advances made in the academic setting and their application in patient care. The journal is a valuable service for clinicians, specialists and physicians-in-training.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信