使用两种不同的义齿基托制作技术对上颌全口义齿固位的影响:活体比较研究

Ayah Abdellatif, Moataz Bahgat, Sayed Elmasry, K. Sultan
{"title":"使用两种不同的义齿基托制作技术对上颌全口义齿固位的影响:活体比较研究","authors":"Ayah Abdellatif, Moataz Bahgat, Sayed Elmasry, K. Sultan","doi":"10.21608/dsu.2024.182953.1152","DOIUrl":null,"url":null,"abstract":"Introduction: Complete denture is used to replace the entire dentition and restore mastication, speech, and aesthetics. All other tooth-supported solutions have been exhausted. Because Computer-Aided Design/ Computer-Aided Manufacturing (CAD/ CAM) dentures are milled from pre-polymerized Polymethyl Methacrylate (PMMA) blocks that do not display polymerization shrinkage, they can eliminate the laboratory processes of acrylic processing (setting up of teeth, try-in, flasking and de flasking). Aim: to compare the retention values of maxillary conventional heat-polymerized denture bases with digitally milled denture bases . Materials and Methods: Sixteen totally edentulous patients participated in the study, which was divided into two groups (n=8) (A) and (B). Patients in the group (A) received traditional heat-cured acrylic resin dentures with a long cycle water path curing procedure, in group (B) received dentures created using the CAD/CAM technique. For both groups, a metallic hook affixed to the geometric center of the maxillary dentures was pulled by a digital force-meter gauge to measure retention. Results: The mean retention values were recorded for both groups, tabulated, and statistically analyzed; the following results were obtained. Regarding group (A), retention values showed a significant increase at the beginning of the study as well as at the end of the study. Regarding group (B), retention values showed a significant initial increase at the beginning of the study, till the end of the study. A significant difference was revealed between the mean retention values of the two tested groups, with clear superiority of the retention of the CAD/CAM acrylic resin dentures (group B) than that of the conventional heat-cured acrylic resin dentures (group A). Conclusion: CAD/CAM acrylic resin dentures were superior in terms of maxillary denture retention compared to conventional heat-cured acrylic resin dentures. Retention was increased gradually over time in both two studied groups.","PeriodicalId":11270,"journal":{"name":"Dental Science Updates","volume":"112 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Using Two Different Techniques of Denture Base Fabrication on Retention of Maxillary Complete Denture: An in Vivo Comparative Study\",\"authors\":\"Ayah Abdellatif, Moataz Bahgat, Sayed Elmasry, K. Sultan\",\"doi\":\"10.21608/dsu.2024.182953.1152\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Introduction: Complete denture is used to replace the entire dentition and restore mastication, speech, and aesthetics. All other tooth-supported solutions have been exhausted. Because Computer-Aided Design/ Computer-Aided Manufacturing (CAD/ CAM) dentures are milled from pre-polymerized Polymethyl Methacrylate (PMMA) blocks that do not display polymerization shrinkage, they can eliminate the laboratory processes of acrylic processing (setting up of teeth, try-in, flasking and de flasking). Aim: to compare the retention values of maxillary conventional heat-polymerized denture bases with digitally milled denture bases . Materials and Methods: Sixteen totally edentulous patients participated in the study, which was divided into two groups (n=8) (A) and (B). Patients in the group (A) received traditional heat-cured acrylic resin dentures with a long cycle water path curing procedure, in group (B) received dentures created using the CAD/CAM technique. For both groups, a metallic hook affixed to the geometric center of the maxillary dentures was pulled by a digital force-meter gauge to measure retention. Results: The mean retention values were recorded for both groups, tabulated, and statistically analyzed; the following results were obtained. Regarding group (A), retention values showed a significant increase at the beginning of the study as well as at the end of the study. Regarding group (B), retention values showed a significant initial increase at the beginning of the study, till the end of the study. A significant difference was revealed between the mean retention values of the two tested groups, with clear superiority of the retention of the CAD/CAM acrylic resin dentures (group B) than that of the conventional heat-cured acrylic resin dentures (group A). Conclusion: CAD/CAM acrylic resin dentures were superior in terms of maxillary denture retention compared to conventional heat-cured acrylic resin dentures. Retention was increased gradually over time in both two studied groups.\",\"PeriodicalId\":11270,\"journal\":{\"name\":\"Dental Science Updates\",\"volume\":\"112 4\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Dental Science Updates\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21608/dsu.2024.182953.1152\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Science Updates","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21608/dsu.2024.182953.1152","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

简介全口义齿用于替代整个牙列,恢复咀嚼、语言和美观。所有其他牙齿支持解决方案均已用尽。由于计算机辅助设计/计算机辅助制造(CAD/ CAM)假牙是由聚甲基丙烯酸甲酯(PMMA)预聚合块研磨而成,不会出现聚合收缩,因此可以省去丙烯酸加工的实验室工序(安装牙齿、试戴、装瓶和脱瓶)。目的:比较上颌传统热聚合义齿基托与数字铣制义齿基托的固位值。材料和方法:16 名全无牙颌患者参加了研究,分为两组(n=8)(A)和(B)。A 组患者使用传统的热固化丙烯酸树脂义齿,采用长周期水路固化程序;B 组患者使用 CAD/CAM 技术制作义齿。两组患者都使用数字测力计拉动上颌假牙几何中心的金属钩,以测量固位情况。结果:记录两组的平均固位值,列表并进行统计分析;结果如下。A组的固位值在研究开始和结束时都有显著增加。至于(B)组,留存率从研究开始到研究结束都有显著增加。两个测试组的平均固位值之间存在明显差异,CAD/CAM丙烯酸树脂义齿(B 组)的固位明显优于传统热固化丙烯酸树脂义齿(A 组)。结论与传统的热固化丙烯酸树脂义齿相比,CAD/CAM丙烯酸树脂义齿在上颌义齿固位方面更具优势。随着时间的推移,两个研究组的义齿固位都在逐渐增加。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of Using Two Different Techniques of Denture Base Fabrication on Retention of Maxillary Complete Denture: An in Vivo Comparative Study
Introduction: Complete denture is used to replace the entire dentition and restore mastication, speech, and aesthetics. All other tooth-supported solutions have been exhausted. Because Computer-Aided Design/ Computer-Aided Manufacturing (CAD/ CAM) dentures are milled from pre-polymerized Polymethyl Methacrylate (PMMA) blocks that do not display polymerization shrinkage, they can eliminate the laboratory processes of acrylic processing (setting up of teeth, try-in, flasking and de flasking). Aim: to compare the retention values of maxillary conventional heat-polymerized denture bases with digitally milled denture bases . Materials and Methods: Sixteen totally edentulous patients participated in the study, which was divided into two groups (n=8) (A) and (B). Patients in the group (A) received traditional heat-cured acrylic resin dentures with a long cycle water path curing procedure, in group (B) received dentures created using the CAD/CAM technique. For both groups, a metallic hook affixed to the geometric center of the maxillary dentures was pulled by a digital force-meter gauge to measure retention. Results: The mean retention values were recorded for both groups, tabulated, and statistically analyzed; the following results were obtained. Regarding group (A), retention values showed a significant increase at the beginning of the study as well as at the end of the study. Regarding group (B), retention values showed a significant initial increase at the beginning of the study, till the end of the study. A significant difference was revealed between the mean retention values of the two tested groups, with clear superiority of the retention of the CAD/CAM acrylic resin dentures (group B) than that of the conventional heat-cured acrylic resin dentures (group A). Conclusion: CAD/CAM acrylic resin dentures were superior in terms of maxillary denture retention compared to conventional heat-cured acrylic resin dentures. Retention was increased gradually over time in both two studied groups.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信