{"title":"表面能对瓷双伞绝缘子污染特性的影响","authors":"Yukun Lv, Qian Wang, Ze Chen, Jiawen Wang","doi":"10.24425/aee.2024.148867","DOIUrl":null,"url":null,"abstract":"To explore the influence of surface energy on the contamination characteristics of insulators, COMSOL Multiphysics software was used to simulate the contamination characteristics of XWP 2-160 insulators under wind tunnel conditions, and the rationality of the modified expression of the dynamic deposition model of the contaminated particles was verified. The change of contamination characteristics before and after changing the surface energy of insulators under natural conditions was simulated and analyzed. The results show that under the original surface energy (72 mJ/m 2) and low surface energy (6.7 mJ/m 2) with the increase in particle size, the contamination amount of an insulator surface area decreases first and then increases. When the wind speed is 2 m/s, the change in the particle size has the most pronounced effect on the amount of contamination. The amounts of contamination for the low surface energy are 64–75%, 60–95%, 55–91% and 54–78% lower than those for the original surface energy for particle sizes of 10, 15, 20 and 25 μm, respectively. For the same wind speed, when the size of contamination particles increases, the difference between the ratio of DC and AC contamination accumulation is gradually increasing because of the influence of the electric field force. From the perspective of the insulator preparation process, the development of low surface energy insulators can improve their anti-fouling performance.","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of surface energy on the contamination characteristics of porcelain double umbrella insulators\",\"authors\":\"Yukun Lv, Qian Wang, Ze Chen, Jiawen Wang\",\"doi\":\"10.24425/aee.2024.148867\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To explore the influence of surface energy on the contamination characteristics of insulators, COMSOL Multiphysics software was used to simulate the contamination characteristics of XWP 2-160 insulators under wind tunnel conditions, and the rationality of the modified expression of the dynamic deposition model of the contaminated particles was verified. The change of contamination characteristics before and after changing the surface energy of insulators under natural conditions was simulated and analyzed. The results show that under the original surface energy (72 mJ/m 2) and low surface energy (6.7 mJ/m 2) with the increase in particle size, the contamination amount of an insulator surface area decreases first and then increases. When the wind speed is 2 m/s, the change in the particle size has the most pronounced effect on the amount of contamination. The amounts of contamination for the low surface energy are 64–75%, 60–95%, 55–91% and 54–78% lower than those for the original surface energy for particle sizes of 10, 15, 20 and 25 μm, respectively. For the same wind speed, when the size of contamination particles increases, the difference between the ratio of DC and AC contamination accumulation is gradually increasing because of the influence of the electric field force. From the perspective of the insulator preparation process, the development of low surface energy insulators can improve their anti-fouling performance.\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24425/aee.2024.148867\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24425/aee.2024.148867","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Effect of surface energy on the contamination characteristics of porcelain double umbrella insulators
To explore the influence of surface energy on the contamination characteristics of insulators, COMSOL Multiphysics software was used to simulate the contamination characteristics of XWP 2-160 insulators under wind tunnel conditions, and the rationality of the modified expression of the dynamic deposition model of the contaminated particles was verified. The change of contamination characteristics before and after changing the surface energy of insulators under natural conditions was simulated and analyzed. The results show that under the original surface energy (72 mJ/m 2) and low surface energy (6.7 mJ/m 2) with the increase in particle size, the contamination amount of an insulator surface area decreases first and then increases. When the wind speed is 2 m/s, the change in the particle size has the most pronounced effect on the amount of contamination. The amounts of contamination for the low surface energy are 64–75%, 60–95%, 55–91% and 54–78% lower than those for the original surface energy for particle sizes of 10, 15, 20 and 25 μm, respectively. For the same wind speed, when the size of contamination particles increases, the difference between the ratio of DC and AC contamination accumulation is gradually increasing because of the influence of the electric field force. From the perspective of the insulator preparation process, the development of low surface energy insulators can improve their anti-fouling performance.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.