{"title":"主动胶囊内窥镜在蠕动肠道中的阻力模型。","authors":"Yi Huang, Liang Liang, Puhua Tang, Zhiming Guo","doi":"10.1177/09544119241239112","DOIUrl":null,"url":null,"abstract":"<p><p>In the past studies, the resistance of magnetically controlled capsules running through the small intestine has been modeled assuming that the small intestine was a circular tube with a constant diameter. Peristalsis is an important character of the human gastrointestinal system, and it would result in some changes in the diameter of the intestine, meaning that the existing resistance models would no longer be applicable. In this paper, based on the assumption that intestinal peristalsis is actually a sinusoidal wave, a resistance model of the capsule running in the peristaltic intestine is established, and then it is validated experimentally. The model provides a realistic foundation for the optimization and control of the magnetically controlled endoscopy.</p>","PeriodicalId":20666,"journal":{"name":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","volume":" ","pages":"529-536"},"PeriodicalIF":1.7000,"publicationDate":"2024-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Resistance model of an active capsule endoscope in a peristaltic intestine.\",\"authors\":\"Yi Huang, Liang Liang, Puhua Tang, Zhiming Guo\",\"doi\":\"10.1177/09544119241239112\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In the past studies, the resistance of magnetically controlled capsules running through the small intestine has been modeled assuming that the small intestine was a circular tube with a constant diameter. Peristalsis is an important character of the human gastrointestinal system, and it would result in some changes in the diameter of the intestine, meaning that the existing resistance models would no longer be applicable. In this paper, based on the assumption that intestinal peristalsis is actually a sinusoidal wave, a resistance model of the capsule running in the peristaltic intestine is established, and then it is validated experimentally. The model provides a realistic foundation for the optimization and control of the magnetically controlled endoscopy.</p>\",\"PeriodicalId\":20666,\"journal\":{\"name\":\"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine\",\"volume\":\" \",\"pages\":\"529-536\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1177/09544119241239112\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1177/09544119241239112","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/22 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Resistance model of an active capsule endoscope in a peristaltic intestine.
In the past studies, the resistance of magnetically controlled capsules running through the small intestine has been modeled assuming that the small intestine was a circular tube with a constant diameter. Peristalsis is an important character of the human gastrointestinal system, and it would result in some changes in the diameter of the intestine, meaning that the existing resistance models would no longer be applicable. In this paper, based on the assumption that intestinal peristalsis is actually a sinusoidal wave, a resistance model of the capsule running in the peristaltic intestine is established, and then it is validated experimentally. The model provides a realistic foundation for the optimization and control of the magnetically controlled endoscopy.
期刊介绍:
The Journal of Engineering in Medicine is an interdisciplinary journal encompassing all aspects of engineering in medicine. The Journal is a vital tool for maintaining an understanding of the newest techniques and research in medical engineering.