{"title":"基于照相血压计的心率和血压估算与高血压分类","authors":"Aditta Chowdhury ,&nbsp;Diba Das ,&nbsp;Abdelrahman B.M. Eldaly ,&nbsp;Ray C.C. Cheung ,&nbsp;Mehdi Hasan Chowdhury","doi":"10.1016/j.ipemt.2024.100024","DOIUrl":null,"url":null,"abstract":"<div><p>A photoplethysmogram (PPG) is an optically-derived signal that records the variation in blood volume within the microvasculature. Certain cardiovascular diseases (CVDs) are symptomatic of damaged blood vessels and problems in blood flow, including hypertension. While software implementations for heart rate and blood pressure estimation exist, point-of-care systems demand hardware-based implementations for real-time estimations to be useful for CVD detection. In this study, digital field programmable gate array (FPGA) based systems are developed for heart rate and blood pressure estimation from PPG signals by means of linear regression. In addition to the blood pressure estimation system, we present a prototype hypertension level detection system that achieves 92.42% accuracy while consuming 0.364 W of power. The Mean Absolute Error (MAE) <span><math><mo>±</mo></math></span> Standard Deviation (SD) for heart rate estimation is 3.17 ± 2.79 beat per minute. The corresponding results for systolic and diastolic blood-pressure estimation are 4.75 ± 2.78 and 3.34 ± 2.60, respectively. The prototype can be further extended to wearable devices and medical equipment in the future.</p></div>","PeriodicalId":73507,"journal":{"name":"IPEM-translation","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2667258824000025/pdfft?md5=6f5c7e4d5072d04f8f45d83d1cdd8008&pid=1-s2.0-S2667258824000025-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Photoplethysmogram-based heart rate and blood pressure estimation with hypertension classification\",\"authors\":\"Aditta Chowdhury ,&nbsp;Diba Das ,&nbsp;Abdelrahman B.M. Eldaly ,&nbsp;Ray C.C. Cheung ,&nbsp;Mehdi Hasan Chowdhury\",\"doi\":\"10.1016/j.ipemt.2024.100024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A photoplethysmogram (PPG) is an optically-derived signal that records the variation in blood volume within the microvasculature. Certain cardiovascular diseases (CVDs) are symptomatic of damaged blood vessels and problems in blood flow, including hypertension. While software implementations for heart rate and blood pressure estimation exist, point-of-care systems demand hardware-based implementations for real-time estimations to be useful for CVD detection. In this study, digital field programmable gate array (FPGA) based systems are developed for heart rate and blood pressure estimation from PPG signals by means of linear regression. In addition to the blood pressure estimation system, we present a prototype hypertension level detection system that achieves 92.42% accuracy while consuming 0.364 W of power. The Mean Absolute Error (MAE) <span><math><mo>±</mo></math></span> Standard Deviation (SD) for heart rate estimation is 3.17 ± 2.79 beat per minute. The corresponding results for systolic and diastolic blood-pressure estimation are 4.75 ± 2.78 and 3.34 ± 2.60, respectively. The prototype can be further extended to wearable devices and medical equipment in the future.</p></div>\",\"PeriodicalId\":73507,\"journal\":{\"name\":\"IPEM-translation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2667258824000025/pdfft?md5=6f5c7e4d5072d04f8f45d83d1cdd8008&pid=1-s2.0-S2667258824000025-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IPEM-translation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2667258824000025\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IPEM-translation","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667258824000025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

光敏血流图(PPG)是一种光学衍生信号,可记录微血管内的血容量变化。某些心血管疾病(CVD)的症状是血管受损和血流问题,包括高血压。虽然已有用于心率和血压估算的软件实现方法,但护理点系统需要基于硬件的实现方法来进行实时估算,以便用于 CVD 检测。本研究开发了基于数字现场可编程门阵列(FPGA)的系统,通过线性回归的方法从 PPG 信号估算心率和血压。除了血压估算系统外,我们还展示了一个高血压水平检测系统原型,其准确率达到 92.42%,而功耗仅为 0.364 W。心率估计的平均绝对误差(MAE)± 标准偏差(SD)为每分钟 3.17±2.79 次。相应的收缩压和舒张压估计结果分别为 4.75 ± 2.78 和 3.34 ± 2.60。未来,该原型可进一步扩展到可穿戴设备和医疗设备。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Photoplethysmogram-based heart rate and blood pressure estimation with hypertension classification

Photoplethysmogram-based heart rate and blood pressure estimation with hypertension classification

A photoplethysmogram (PPG) is an optically-derived signal that records the variation in blood volume within the microvasculature. Certain cardiovascular diseases (CVDs) are symptomatic of damaged blood vessels and problems in blood flow, including hypertension. While software implementations for heart rate and blood pressure estimation exist, point-of-care systems demand hardware-based implementations for real-time estimations to be useful for CVD detection. In this study, digital field programmable gate array (FPGA) based systems are developed for heart rate and blood pressure estimation from PPG signals by means of linear regression. In addition to the blood pressure estimation system, we present a prototype hypertension level detection system that achieves 92.42% accuracy while consuming 0.364 W of power. The Mean Absolute Error (MAE) ± Standard Deviation (SD) for heart rate estimation is 3.17 ± 2.79 beat per minute. The corresponding results for systolic and diastolic blood-pressure estimation are 4.75 ± 2.78 and 3.34 ± 2.60, respectively. The prototype can be further extended to wearable devices and medical equipment in the future.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IPEM-translation
IPEM-translation Medicine and Dentistry (General)
自引率
0.00%
发文量
0
审稿时长
63 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信