{"title":"红细胞凝集的解离现象及其在临床实验室检测补体系统功能活性中的应用。","authors":"Xuewei Ding, Lina Liu, Guang Yang, Hui Liu","doi":"10.1002/jcla.25028","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>The objective of the study was to validate the dissociation phenomenon of erythrocyte agglutination which is based on erythrocyte fragments and to apply it in the functional activity assay of the complement system.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>The dissociation–agglutination effect of erythrocyte fragments was validated by detecting the number of free erythrocytes after the action of erythrocyte fragments on agglutinated erythrocytes. The number of free erythrocytes produced after hemolysis of agglutinated erythrocytes caused by complements and complement activators(CAs) was detected by auto hematology analyzer and the results were indicated by mean hemoglobin concentration of erythrocytes (MCHC). We optimized the test conditions and validated the inter-batch stability, explored the resolution of the assay method, and assayed for the total complement activity (AC) and the CAs activated complement activity (ACA) in serum from patients and healthy individual groups.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Erythrocyte fragments have a dissociative effect on agglutinated erythrocytes. The auto hematology analyzer was able to detect AC and ACA, where AC showed an inverse correlation with MCHC, and ACA demonstrated a positive correlation with MCHC. The inter-batch CV of AC, ACA, and ACA/AC was found to be 5%, 9%, and 11.7%, respectively, with good stability. The study found that serum samples from acute phase reaction patients showed significant differences in ACA compared with healthy individuals, with a <i>p</i> value of 0.018; serum samples from patients with nephrotic syndrome showed significant differences in AC, ACA, and ACA/AC compared with healthy individuals, with <i>p</i> values of 0.014, 0.002, and 0.041, respectively.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Erythrocyte fragments have dissociation–agglutination effect. The complement system immunological functional detection method, based on this effect, has potential clinical application value due to its sensitivity and accuracy.</p>\n </section>\n </div>","PeriodicalId":15509,"journal":{"name":"Journal of Clinical Laboratory Analysis","volume":"38 6","pages":""},"PeriodicalIF":2.6000,"publicationDate":"2024-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jcla.25028","citationCount":"0","resultStr":"{\"title\":\"Dissociation Phenomenon of Erythrocyte Agglutination and Its Application to Assay of Functional Activity of the Complement System in Clinical Laboratory\",\"authors\":\"Xuewei Ding, Lina Liu, Guang Yang, Hui Liu\",\"doi\":\"10.1002/jcla.25028\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objective</h3>\\n \\n <p>The objective of the study was to validate the dissociation phenomenon of erythrocyte agglutination which is based on erythrocyte fragments and to apply it in the functional activity assay of the complement system.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>The dissociation–agglutination effect of erythrocyte fragments was validated by detecting the number of free erythrocytes after the action of erythrocyte fragments on agglutinated erythrocytes. The number of free erythrocytes produced after hemolysis of agglutinated erythrocytes caused by complements and complement activators(CAs) was detected by auto hematology analyzer and the results were indicated by mean hemoglobin concentration of erythrocytes (MCHC). We optimized the test conditions and validated the inter-batch stability, explored the resolution of the assay method, and assayed for the total complement activity (AC) and the CAs activated complement activity (ACA) in serum from patients and healthy individual groups.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Erythrocyte fragments have a dissociative effect on agglutinated erythrocytes. The auto hematology analyzer was able to detect AC and ACA, where AC showed an inverse correlation with MCHC, and ACA demonstrated a positive correlation with MCHC. The inter-batch CV of AC, ACA, and ACA/AC was found to be 5%, 9%, and 11.7%, respectively, with good stability. The study found that serum samples from acute phase reaction patients showed significant differences in ACA compared with healthy individuals, with a <i>p</i> value of 0.018; serum samples from patients with nephrotic syndrome showed significant differences in AC, ACA, and ACA/AC compared with healthy individuals, with <i>p</i> values of 0.014, 0.002, and 0.041, respectively.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>Erythrocyte fragments have dissociation–agglutination effect. The complement system immunological functional detection method, based on this effect, has potential clinical application value due to its sensitivity and accuracy.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15509,\"journal\":{\"name\":\"Journal of Clinical Laboratory Analysis\",\"volume\":\"38 6\",\"pages\":\"\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/jcla.25028\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Clinical Laboratory Analysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/jcla.25028\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Laboratory Analysis","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/jcla.25028","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
Dissociation Phenomenon of Erythrocyte Agglutination and Its Application to Assay of Functional Activity of the Complement System in Clinical Laboratory
Objective
The objective of the study was to validate the dissociation phenomenon of erythrocyte agglutination which is based on erythrocyte fragments and to apply it in the functional activity assay of the complement system.
Methods
The dissociation–agglutination effect of erythrocyte fragments was validated by detecting the number of free erythrocytes after the action of erythrocyte fragments on agglutinated erythrocytes. The number of free erythrocytes produced after hemolysis of agglutinated erythrocytes caused by complements and complement activators(CAs) was detected by auto hematology analyzer and the results were indicated by mean hemoglobin concentration of erythrocytes (MCHC). We optimized the test conditions and validated the inter-batch stability, explored the resolution of the assay method, and assayed for the total complement activity (AC) and the CAs activated complement activity (ACA) in serum from patients and healthy individual groups.
Results
Erythrocyte fragments have a dissociative effect on agglutinated erythrocytes. The auto hematology analyzer was able to detect AC and ACA, where AC showed an inverse correlation with MCHC, and ACA demonstrated a positive correlation with MCHC. The inter-batch CV of AC, ACA, and ACA/AC was found to be 5%, 9%, and 11.7%, respectively, with good stability. The study found that serum samples from acute phase reaction patients showed significant differences in ACA compared with healthy individuals, with a p value of 0.018; serum samples from patients with nephrotic syndrome showed significant differences in AC, ACA, and ACA/AC compared with healthy individuals, with p values of 0.014, 0.002, and 0.041, respectively.
Conclusion
Erythrocyte fragments have dissociation–agglutination effect. The complement system immunological functional detection method, based on this effect, has potential clinical application value due to its sensitivity and accuracy.
期刊介绍:
Journal of Clinical Laboratory Analysis publishes original articles on newly developing modes of technology and laboratory assays, with emphasis on their application in current and future clinical laboratory testing. This includes reports from the following fields: immunochemistry and toxicology, hematology and hematopathology, immunopathology, molecular diagnostics, microbiology, genetic testing, immunohematology, and clinical chemistry.