利用快速 T2 映射和 T2 准备对 17O 标记的水进行成像:模型研究

Hiroyuki Kameda, Yumi Nakada, Yuta Urushibata, Hiroyuki Sugimori, Takaaki Fujii, Naoya Kinota, Daisuke Kato, Minghui Tang, Keita Sakamoto, Kohsuke Kudo
{"title":"利用快速 T2 映射和 T2 准备对 17O 标记的水进行成像:模型研究","authors":"Hiroyuki Kameda, Yumi Nakada, Yuta Urushibata, Hiroyuki Sugimori, Takaaki Fujii, Naoya Kinota, Daisuke Kato, Minghui Tang, Keita Sakamoto, Kohsuke Kudo","doi":"10.2463/mrms.tn.2023-0152","DOIUrl":null,"url":null,"abstract":"<p><p><sup>17</sup>O-labeled water is a T2-shortening contrast agent used in proton MRI and is a promising method for visualizing cerebrospinal fluid (CSF) dynamics because it provides long-term tracking of water molecules. However, various external factors reduce the accuracy of <sup>17</sup>O-concentration measurements using conventional signal-intensity-based methods. In addition, T2 mapping, which is expected to provide a stable assessment, is generally limited to temporal-spatial resolution. We developed the T2-prepared based on T2 mapping used in cardiac imaging to adapt to long T2 values and tested whether it could accurately measure <sup>17</sup>O-concentration in the CSF using a phantom. The results showed that <sup>17</sup>O-concentration in a fluid mimicking CSF could be evaluated with an accuracy comparable to conventional T2-mapping (Carr-Purcell-Meiboom-Gill multi-echo spin-echo method). This method allows <sup>17</sup>O-imaging with a high temporal resolution and stability in proton MRI. This imaging technique may be promising for visualizing CSF dynamics using <sup>17</sup>O-labeled water.</p>","PeriodicalId":94126,"journal":{"name":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Imaging of <sup>17</sup>O-labeled Water Using Fast T2 Mapping with T2-preparation: A Phantom Study.\",\"authors\":\"Hiroyuki Kameda, Yumi Nakada, Yuta Urushibata, Hiroyuki Sugimori, Takaaki Fujii, Naoya Kinota, Daisuke Kato, Minghui Tang, Keita Sakamoto, Kohsuke Kudo\",\"doi\":\"10.2463/mrms.tn.2023-0152\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><sup>17</sup>O-labeled water is a T2-shortening contrast agent used in proton MRI and is a promising method for visualizing cerebrospinal fluid (CSF) dynamics because it provides long-term tracking of water molecules. However, various external factors reduce the accuracy of <sup>17</sup>O-concentration measurements using conventional signal-intensity-based methods. In addition, T2 mapping, which is expected to provide a stable assessment, is generally limited to temporal-spatial resolution. We developed the T2-prepared based on T2 mapping used in cardiac imaging to adapt to long T2 values and tested whether it could accurately measure <sup>17</sup>O-concentration in the CSF using a phantom. The results showed that <sup>17</sup>O-concentration in a fluid mimicking CSF could be evaluated with an accuracy comparable to conventional T2-mapping (Carr-Purcell-Meiboom-Gill multi-echo spin-echo method). This method allows <sup>17</sup>O-imaging with a high temporal resolution and stability in proton MRI. This imaging technique may be promising for visualizing CSF dynamics using <sup>17</sup>O-labeled water.</p>\",\"PeriodicalId\":94126,\"journal\":{\"name\":\"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2463/mrms.tn.2023-0152\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2463/mrms.tn.2023-0152","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

17O 标记的水是质子磁共振成像中使用的一种 T2 缩短造影剂,由于它能对水分子进行长期追踪,因此是一种很有前景的脑脊液(CSF)动态可视化方法。然而,各种外部因素降低了使用基于信号强度的传统方法测量 17O 浓度的准确性。此外,T2 映射有望提供稳定的评估,但一般仅限于时间空间分辨率。我们在心脏成像中使用的 T2 映射的基础上开发了 T2 准备,以适应长 T2 值,并使用模型测试了它是否能准确测量 CSF 中的 17O 浓度。结果表明,模拟 CSF 的液体中 17O 浓度的评估准确度可与传统 T2 映射(Carr-Purcell-Meiboom-Gill 多回波自旋回波法)媲美。这种方法可在质子磁共振成像中实现高时间分辨率和高稳定性的 17O 成像。这种成像技术在使用 17O 标记的水观察 CSF 动态方面大有可为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Imaging of 17O-labeled Water Using Fast T2 Mapping with T2-preparation: A Phantom Study.

17O-labeled water is a T2-shortening contrast agent used in proton MRI and is a promising method for visualizing cerebrospinal fluid (CSF) dynamics because it provides long-term tracking of water molecules. However, various external factors reduce the accuracy of 17O-concentration measurements using conventional signal-intensity-based methods. In addition, T2 mapping, which is expected to provide a stable assessment, is generally limited to temporal-spatial resolution. We developed the T2-prepared based on T2 mapping used in cardiac imaging to adapt to long T2 values and tested whether it could accurately measure 17O-concentration in the CSF using a phantom. The results showed that 17O-concentration in a fluid mimicking CSF could be evaluated with an accuracy comparable to conventional T2-mapping (Carr-Purcell-Meiboom-Gill multi-echo spin-echo method). This method allows 17O-imaging with a high temporal resolution and stability in proton MRI. This imaging technique may be promising for visualizing CSF dynamics using 17O-labeled water.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信