{"title":"利用多维计算机适应性测试测量流体推理的过程因素。","authors":"Hanif Akhtar, Kristof Kovacs","doi":"10.1177/10731911241236351","DOIUrl":null,"url":null,"abstract":"<p><p>Although many fluid reasoning (Gf) tests have been developed, there is a lack of figural tests measuring its lower-order process factors simultaneously. The present article introduces the development of the Multidimensional Induction-Deduction Computerized Adaptive Test (MID-CAT) to measure two process factors of Gf. The MID-CAT is designed to provide an instrument that is flexible, efficient, and entirely free for non-commercial use. We created 530 items and administered them to a sample of <i>N</i> = 2,247. Items were fitted and calibrated using the Rasch model. The results indicate that the final item pool has a wide range of difficulties that could precisely measure a wide range of test-takers' abilities. A simulation study also indicates that MID-CAT provides greater measurement efficiency than separate-unidimensional CAT or fixed-item test. In the discussion, we provide perspectives on how the MID-CAT can be used for future research.</p>","PeriodicalId":8577,"journal":{"name":"Assessment","volume":" ","pages":"32-47"},"PeriodicalIF":3.5000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measuring Process Factors of Fluid Reasoning Using Multidimensional Computerized Adaptive Testing.\",\"authors\":\"Hanif Akhtar, Kristof Kovacs\",\"doi\":\"10.1177/10731911241236351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Although many fluid reasoning (Gf) tests have been developed, there is a lack of figural tests measuring its lower-order process factors simultaneously. The present article introduces the development of the Multidimensional Induction-Deduction Computerized Adaptive Test (MID-CAT) to measure two process factors of Gf. The MID-CAT is designed to provide an instrument that is flexible, efficient, and entirely free for non-commercial use. We created 530 items and administered them to a sample of <i>N</i> = 2,247. Items were fitted and calibrated using the Rasch model. The results indicate that the final item pool has a wide range of difficulties that could precisely measure a wide range of test-takers' abilities. A simulation study also indicates that MID-CAT provides greater measurement efficiency than separate-unidimensional CAT or fixed-item test. In the discussion, we provide perspectives on how the MID-CAT can be used for future research.</p>\",\"PeriodicalId\":8577,\"journal\":{\"name\":\"Assessment\",\"volume\":\" \",\"pages\":\"32-47\"},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Assessment\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://doi.org/10.1177/10731911241236351\",\"RegionNum\":2,\"RegionCategory\":\"心理学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"PSYCHOLOGY, CLINICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Assessment","FirstCategoryId":"88","ListUrlMain":"https://doi.org/10.1177/10731911241236351","RegionNum":2,"RegionCategory":"心理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/16 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"PSYCHOLOGY, CLINICAL","Score":null,"Total":0}
Measuring Process Factors of Fluid Reasoning Using Multidimensional Computerized Adaptive Testing.
Although many fluid reasoning (Gf) tests have been developed, there is a lack of figural tests measuring its lower-order process factors simultaneously. The present article introduces the development of the Multidimensional Induction-Deduction Computerized Adaptive Test (MID-CAT) to measure two process factors of Gf. The MID-CAT is designed to provide an instrument that is flexible, efficient, and entirely free for non-commercial use. We created 530 items and administered them to a sample of N = 2,247. Items were fitted and calibrated using the Rasch model. The results indicate that the final item pool has a wide range of difficulties that could precisely measure a wide range of test-takers' abilities. A simulation study also indicates that MID-CAT provides greater measurement efficiency than separate-unidimensional CAT or fixed-item test. In the discussion, we provide perspectives on how the MID-CAT can be used for future research.
期刊介绍:
Assessment publishes articles in the domain of applied clinical assessment. The emphasis of this journal is on publication of information of relevance to the use of assessment measures, including test development, validation, and interpretation practices. The scope of the journal includes research that can inform assessment practices in mental health, forensic, medical, and other applied settings. Papers that focus on the assessment of cognitive and neuropsychological functioning, personality, and psychopathology are invited. Most papers published in Assessment report the results of original empirical research, however integrative review articles and scholarly case studies will also be considered.