基于分子对接和 ADMET 分析策略的托瑞米芬稳定性指示 RP-HPLC-PDA 方法开发与验证

Shamshir Khan, Makhmur Ahmad, Zabih Ullah, Sana Hashmi, Md Sajid Ali, Sharwan Hudda
{"title":"基于分子对接和 ADMET 分析策略的托瑞米芬稳定性指示 RP-HPLC-PDA 方法开发与验证","authors":"Shamshir Khan, Makhmur Ahmad, Zabih Ullah, Sana Hashmi, Md Sajid Ali, Sharwan Hudda","doi":"10.2174/0115734099289409240307042531","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The purpose of this research is to develop an analytical method and validate it according to ICH guidelines for the estimation of Toremifene by RP-HPLC-PDA with molecular docking and ADMET analysis. From molecular docking, it came to know the receptor affinity specifically to estrogen receptors (ERα and ERβ), which are responsible for cancer therapy. ADMET analyses secure its therapeutic potential as well safety of the drug.</p><p><strong>Methods: </strong>An isocratic method has developed by RP-HPLC-PDA (AGILENT 1100) with symmetry of 100 mm x 4.6 mm x 5 μm particle size C18 column and optimise mobile phase is methanol: 0.1% OPA (orthophosphoric acid) water ratio of 43:57% v/v. Under different conditions like acidic, alkaline, oxidative, and neutral environments, toremifene was tested for degradation.</p><p><strong>Results: </strong>The developed method is validated in accordance with ICH guidelines. A calibration curve with an r2 value of 0.9987 has been prepared across the range of 10 to 50 μg/ml with five standard dilutions. The retention time of the drug is 5.575 minutes. The validation results are system suitability (%RSD-0.76), inter-day precision (%RSD 0.14-0.29), intraday precision (%RSD 0.08-0.34), accuracy (%RSD 0.16-0.96), and robustness (%RSD 0.16-0.35). In different intended conditions, four peaks are in 1 N HCl, two peaks in 1 N NaOH, three peaks in 10% H2O2 (1hr), and one peak in neutral.</p><p><strong>Conclusion: </strong>Toremifene, a Selective Estrogen Receptor Modulator (SERM), Drug pharmacokinetic properties and receptor binding affinity results are helpful in designing the analytical method. Developing the RP-HPLC-PDA method is found to be novel, simple and precise. It could be used for testing toremifene in bulk and pharmaceutical tablet dosage forms in quality control, as well as stability tests.</p>","PeriodicalId":93961,"journal":{"name":"Current computer-aided drug design","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Molecular Docking and ADMET Analysis Strategy-Based Stability Indicating RP-HPLC-PDA Method Development and Validation of Toremifene.\",\"authors\":\"Shamshir Khan, Makhmur Ahmad, Zabih Ullah, Sana Hashmi, Md Sajid Ali, Sharwan Hudda\",\"doi\":\"10.2174/0115734099289409240307042531\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The purpose of this research is to develop an analytical method and validate it according to ICH guidelines for the estimation of Toremifene by RP-HPLC-PDA with molecular docking and ADMET analysis. From molecular docking, it came to know the receptor affinity specifically to estrogen receptors (ERα and ERβ), which are responsible for cancer therapy. ADMET analyses secure its therapeutic potential as well safety of the drug.</p><p><strong>Methods: </strong>An isocratic method has developed by RP-HPLC-PDA (AGILENT 1100) with symmetry of 100 mm x 4.6 mm x 5 μm particle size C18 column and optimise mobile phase is methanol: 0.1% OPA (orthophosphoric acid) water ratio of 43:57% v/v. Under different conditions like acidic, alkaline, oxidative, and neutral environments, toremifene was tested for degradation.</p><p><strong>Results: </strong>The developed method is validated in accordance with ICH guidelines. A calibration curve with an r2 value of 0.9987 has been prepared across the range of 10 to 50 μg/ml with five standard dilutions. The retention time of the drug is 5.575 minutes. The validation results are system suitability (%RSD-0.76), inter-day precision (%RSD 0.14-0.29), intraday precision (%RSD 0.08-0.34), accuracy (%RSD 0.16-0.96), and robustness (%RSD 0.16-0.35). In different intended conditions, four peaks are in 1 N HCl, two peaks in 1 N NaOH, three peaks in 10% H2O2 (1hr), and one peak in neutral.</p><p><strong>Conclusion: </strong>Toremifene, a Selective Estrogen Receptor Modulator (SERM), Drug pharmacokinetic properties and receptor binding affinity results are helpful in designing the analytical method. Developing the RP-HPLC-PDA method is found to be novel, simple and precise. It could be used for testing toremifene in bulk and pharmaceutical tablet dosage forms in quality control, as well as stability tests.</p>\",\"PeriodicalId\":93961,\"journal\":{\"name\":\"Current computer-aided drug design\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current computer-aided drug design\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2174/0115734099289409240307042531\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current computer-aided drug design","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/0115734099289409240307042531","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究背景本研究的目的是开发一种分析方法,并根据 ICH 指南通过 RP-HPLC-PDA 结合分子对接和 ADMET 分析方法进行验证。通过分子对接,研究人员了解到托瑞米芬与雌激素受体(ERα和ERβ)的亲和力,而雌激素受体是癌症治疗的关键。ADMET 分析确保了药物的治疗潜力和安全性:采用对称性 100 mm x 4.6 mm x 5 μm 粒径 C18 色谱柱 RP-HPLC-PDA (AGILENT 1100),优化流动相为甲醇:0.1% OPA(正磷酸),水比为 43:57% v/v。在酸性、碱性、氧化性和中性等不同条件下,测试了托瑞米芬的降解情况:结果:所开发的方法按照 ICH 指南进行了验证。用五种标准稀释液在 10 至 50 μg/ml 范围内绘制了一条 r2 值为 0.9987 的校准曲线。药物的保留时间为 5.575 分钟。验证结果包括系统适用性(%RSD-0.76)、日间精密度(%RSD 0.14-0.29)、日内精密度(%RSD 0.08-0.34)、准确度(%RSD 0.16-0.96)和稳健性(%RSD 0.16-0.35)。在不同的预定条件下,1 N HCl 溶液中有四个峰,1 N NaOH 溶液中有两个峰,10% H2O2(1 小时)溶液中有三个峰,中性溶液中有一个峰:托瑞米芬是一种选择性雌激素受体调节剂(SERM),其药物动力学特性和受体结合亲和力结果有助于设计分析方法。RP-HPLC-PDA方法新颖、简便、精确。该方法可用于检测散装和药用片剂中的托瑞米芬的质量控制和稳定性测试。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Molecular Docking and ADMET Analysis Strategy-Based Stability Indicating RP-HPLC-PDA Method Development and Validation of Toremifene.

Background: The purpose of this research is to develop an analytical method and validate it according to ICH guidelines for the estimation of Toremifene by RP-HPLC-PDA with molecular docking and ADMET analysis. From molecular docking, it came to know the receptor affinity specifically to estrogen receptors (ERα and ERβ), which are responsible for cancer therapy. ADMET analyses secure its therapeutic potential as well safety of the drug.

Methods: An isocratic method has developed by RP-HPLC-PDA (AGILENT 1100) with symmetry of 100 mm x 4.6 mm x 5 μm particle size C18 column and optimise mobile phase is methanol: 0.1% OPA (orthophosphoric acid) water ratio of 43:57% v/v. Under different conditions like acidic, alkaline, oxidative, and neutral environments, toremifene was tested for degradation.

Results: The developed method is validated in accordance with ICH guidelines. A calibration curve with an r2 value of 0.9987 has been prepared across the range of 10 to 50 μg/ml with five standard dilutions. The retention time of the drug is 5.575 minutes. The validation results are system suitability (%RSD-0.76), inter-day precision (%RSD 0.14-0.29), intraday precision (%RSD 0.08-0.34), accuracy (%RSD 0.16-0.96), and robustness (%RSD 0.16-0.35). In different intended conditions, four peaks are in 1 N HCl, two peaks in 1 N NaOH, three peaks in 10% H2O2 (1hr), and one peak in neutral.

Conclusion: Toremifene, a Selective Estrogen Receptor Modulator (SERM), Drug pharmacokinetic properties and receptor binding affinity results are helpful in designing the analytical method. Developing the RP-HPLC-PDA method is found to be novel, simple and precise. It could be used for testing toremifene in bulk and pharmaceutical tablet dosage forms in quality control, as well as stability tests.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信