{"title":"土耳其版学前听力环境和生活质量反思问卷的有效性和可靠性。","authors":"Sinem Kırseven, Emel Tahir, Özlem Cangökçe Yaşar","doi":"10.1044/2024_AJA-23-00033","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The purpose of this study was to assess preschool children's hearing-related quality of life and to introduce the scale, originally titled \"Preschool Hearing Environments and Reflections on Quality of Life Questionnaire\" (Preschool HEAR-QL), to the literature through Turkish adaption, validity, and reliability analyses.</p><p><strong>Method: </strong>Our study included 210 children aged 2-6 years: 110 with hearing loss (56 cochlear implant users and 54 hearing aid users) and 100 with normal hearing. Demographic data were collected and then the Preschool HEAR-QL, which was translated into Turkish, was administered twice at 15-day intervals. Confirmatory factor analysis was used to determine whether the factor structure found in the original scale development study was confirmed in our sample (construct validity). Cronbach's alpha, intraclass correlation scores, and the test-retest method were used to assess the scale's reliability as the findings were analyzed using paired samples <i>t</i> tests.</p><p><strong>Results: </strong>The children with hearing loss had lower scores than their normal-hearing peers, and the difference was significant in the subdomains of behavior and attention, hearing environments, and communication. The subscale of the Preschool Period Listening Environments and their Reflections on Quality of Life Scale consists of 23 items, and Cronbach's alpha value was found as 0.922 in the first application and 0.926 in the second application (high reliability). In the model established for validity analysis, χ<sup>2</sup>/<i>df</i> = 2.156, root-mean-square error of approximation = 0.074, standard root-mean-square residual = 0.078, goodness-of-fit index = 0.830, adjusted goodness-of-fit index = 0.789, comparative fit index = 0.895, and Tucker-Lewis index = 0.881 (good model fit). In terms of test-retest reliability, the correlation between the two measurements was 0.837, and there was no statistical difference between the test-retest scores (<i>p</i> = .15).</p><p><strong>Conclusion: </strong>The Turkish version of the Preschool HEAR-QL scale was proven to be a valid and reliable scale for assessing the hearing-related quality of life of children aged 2-6 years.</p><p><strong>Supplemental material: </strong>https://doi.org/10.23641/asha.25236949.</p>","PeriodicalId":49241,"journal":{"name":"American Journal of Audiology","volume":" ","pages":"343-353"},"PeriodicalIF":1.4000,"publicationDate":"2024-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Validity and Reliability of the Turkish Version of Preschool Hearing Environments and Reflection on Quality of Life Questionnaire.\",\"authors\":\"Sinem Kırseven, Emel Tahir, Özlem Cangökçe Yaşar\",\"doi\":\"10.1044/2024_AJA-23-00033\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The purpose of this study was to assess preschool children's hearing-related quality of life and to introduce the scale, originally titled \\\"Preschool Hearing Environments and Reflections on Quality of Life Questionnaire\\\" (Preschool HEAR-QL), to the literature through Turkish adaption, validity, and reliability analyses.</p><p><strong>Method: </strong>Our study included 210 children aged 2-6 years: 110 with hearing loss (56 cochlear implant users and 54 hearing aid users) and 100 with normal hearing. Demographic data were collected and then the Preschool HEAR-QL, which was translated into Turkish, was administered twice at 15-day intervals. Confirmatory factor analysis was used to determine whether the factor structure found in the original scale development study was confirmed in our sample (construct validity). Cronbach's alpha, intraclass correlation scores, and the test-retest method were used to assess the scale's reliability as the findings were analyzed using paired samples <i>t</i> tests.</p><p><strong>Results: </strong>The children with hearing loss had lower scores than their normal-hearing peers, and the difference was significant in the subdomains of behavior and attention, hearing environments, and communication. The subscale of the Preschool Period Listening Environments and their Reflections on Quality of Life Scale consists of 23 items, and Cronbach's alpha value was found as 0.922 in the first application and 0.926 in the second application (high reliability). In the model established for validity analysis, χ<sup>2</sup>/<i>df</i> = 2.156, root-mean-square error of approximation = 0.074, standard root-mean-square residual = 0.078, goodness-of-fit index = 0.830, adjusted goodness-of-fit index = 0.789, comparative fit index = 0.895, and Tucker-Lewis index = 0.881 (good model fit). In terms of test-retest reliability, the correlation between the two measurements was 0.837, and there was no statistical difference between the test-retest scores (<i>p</i> = .15).</p><p><strong>Conclusion: </strong>The Turkish version of the Preschool HEAR-QL scale was proven to be a valid and reliable scale for assessing the hearing-related quality of life of children aged 2-6 years.</p><p><strong>Supplemental material: </strong>https://doi.org/10.23641/asha.25236949.</p>\",\"PeriodicalId\":49241,\"journal\":{\"name\":\"American Journal of Audiology\",\"volume\":\" \",\"pages\":\"343-353\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-06-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Audiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1044/2024_AJA-23-00033\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Audiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1044/2024_AJA-23-00033","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/15 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
The Validity and Reliability of the Turkish Version of Preschool Hearing Environments and Reflection on Quality of Life Questionnaire.
Purpose: The purpose of this study was to assess preschool children's hearing-related quality of life and to introduce the scale, originally titled "Preschool Hearing Environments and Reflections on Quality of Life Questionnaire" (Preschool HEAR-QL), to the literature through Turkish adaption, validity, and reliability analyses.
Method: Our study included 210 children aged 2-6 years: 110 with hearing loss (56 cochlear implant users and 54 hearing aid users) and 100 with normal hearing. Demographic data were collected and then the Preschool HEAR-QL, which was translated into Turkish, was administered twice at 15-day intervals. Confirmatory factor analysis was used to determine whether the factor structure found in the original scale development study was confirmed in our sample (construct validity). Cronbach's alpha, intraclass correlation scores, and the test-retest method were used to assess the scale's reliability as the findings were analyzed using paired samples t tests.
Results: The children with hearing loss had lower scores than their normal-hearing peers, and the difference was significant in the subdomains of behavior and attention, hearing environments, and communication. The subscale of the Preschool Period Listening Environments and their Reflections on Quality of Life Scale consists of 23 items, and Cronbach's alpha value was found as 0.922 in the first application and 0.926 in the second application (high reliability). In the model established for validity analysis, χ2/df = 2.156, root-mean-square error of approximation = 0.074, standard root-mean-square residual = 0.078, goodness-of-fit index = 0.830, adjusted goodness-of-fit index = 0.789, comparative fit index = 0.895, and Tucker-Lewis index = 0.881 (good model fit). In terms of test-retest reliability, the correlation between the two measurements was 0.837, and there was no statistical difference between the test-retest scores (p = .15).
Conclusion: The Turkish version of the Preschool HEAR-QL scale was proven to be a valid and reliable scale for assessing the hearing-related quality of life of children aged 2-6 years.
期刊介绍:
Mission: AJA publishes peer-reviewed research and other scholarly articles pertaining to clinical audiology methods and issues, and serves as an outlet for discussion of related professional and educational issues and ideas. The journal is an international outlet for research on clinical research pertaining to screening, diagnosis, management and outcomes of hearing and balance disorders as well as the etiologies and characteristics of these disorders. The clinical orientation of the journal allows for the publication of reports on audiology as implemented nationally and internationally, including novel clinical procedures, approaches, and cases. AJA seeks to advance evidence-based practice by disseminating the results of new studies as well as providing a forum for critical reviews and meta-analyses of previously published work.
Scope: The broad field of clinical audiology, including audiologic/aural rehabilitation; balance and balance disorders; cultural and linguistic diversity; detection, diagnosis, prevention, habilitation, rehabilitation, and monitoring of hearing loss; hearing aids, cochlear implants, and hearing-assistive technology; hearing disorders; lifespan perspectives on auditory function; speech perception; and tinnitus.