新型优化预包埋抗体标记相关光电子显微镜技术。

Access microbiology Pub Date : 2024-02-20 eCollection Date: 2024-01-01 DOI:10.1099/acmi.0.000750.v3
Nicole Doyle, Jennifer Simpson, Philippa C Hawes, Helena J Maier
{"title":"新型优化预包埋抗体标记相关光电子显微镜技术。","authors":"Nicole Doyle, Jennifer Simpson, Philippa C Hawes, Helena J Maier","doi":"10.1099/acmi.0.000750.v3","DOIUrl":null,"url":null,"abstract":"<p><p>In the intricate environment of a cell, many studies seek to discover the location of specific events or objects of interest. Advances in microscopy in recent years have allowed for high detail views of specific areas of cells of interest using correlative light electron microscopy (CLEM). While this powerful technique allows for the correlation of a specific area of fluorescence on a confocal microscope with that same area in an electron microscope, it is most often used to study tagged proteins of interest. This method adapts the correlative method for use with antibody labelling. We have shown that some cellular structures are more sensitive than others to this process and that this can be a useful technique for laboratories where tagged proteins or viruses, or dedicated CLEM instruments are not available.</p>","PeriodicalId":94366,"journal":{"name":"Access microbiology","volume":"6 2","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10928386/pdf/","citationCount":"0","resultStr":"{\"title\":\"A novel optimized pre-embedding antibody-labelling correlative light electron microscopy technique.\",\"authors\":\"Nicole Doyle, Jennifer Simpson, Philippa C Hawes, Helena J Maier\",\"doi\":\"10.1099/acmi.0.000750.v3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In the intricate environment of a cell, many studies seek to discover the location of specific events or objects of interest. Advances in microscopy in recent years have allowed for high detail views of specific areas of cells of interest using correlative light electron microscopy (CLEM). While this powerful technique allows for the correlation of a specific area of fluorescence on a confocal microscope with that same area in an electron microscope, it is most often used to study tagged proteins of interest. This method adapts the correlative method for use with antibody labelling. We have shown that some cellular structures are more sensitive than others to this process and that this can be a useful technique for laboratories where tagged proteins or viruses, or dedicated CLEM instruments are not available.</p>\",\"PeriodicalId\":94366,\"journal\":{\"name\":\"Access microbiology\",\"volume\":\"6 2\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10928386/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Access microbiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1099/acmi.0.000750.v3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Access microbiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1099/acmi.0.000750.v3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在错综复杂的细胞环境中,许多研究都试图发现特定事件或感兴趣对象的位置。近年来,显微镜技术的进步使得人们可以利用相关光电子显微镜(CLEM)对感兴趣的细胞特定区域进行高细节观察。虽然这种强大的技术可以将共聚焦显微镜上特定区域的荧光与电子显微镜中相同区域的荧光相关联,但它最常用于研究感兴趣的标记蛋白质。这种方法将相关法与抗体标记法相结合。我们已经证明,某些细胞结构对这一过程比其他结构更敏感,对于没有标记蛋白质或病毒或专用 CLEM 仪器的实验室来说,这可能是一项有用的技术。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A novel optimized pre-embedding antibody-labelling correlative light electron microscopy technique.

In the intricate environment of a cell, many studies seek to discover the location of specific events or objects of interest. Advances in microscopy in recent years have allowed for high detail views of specific areas of cells of interest using correlative light electron microscopy (CLEM). While this powerful technique allows for the correlation of a specific area of fluorescence on a confocal microscope with that same area in an electron microscope, it is most often used to study tagged proteins of interest. This method adapts the correlative method for use with antibody labelling. We have shown that some cellular structures are more sensitive than others to this process and that this can be a useful technique for laboratories where tagged proteins or viruses, or dedicated CLEM instruments are not available.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.00
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信