Perla Ibrahim, Jad F Assaf, Romy Bejjani, Julien Torbey, Madeleine Yehia, Saleh Bahir Al-Ulloom, Shady T Awwad
{"title":"角膜塑形镜和正常眼的金字塔形像差计测量的重复性。","authors":"Perla Ibrahim, Jad F Assaf, Romy Bejjani, Julien Torbey, Madeleine Yehia, Saleh Bahir Al-Ulloom, Shady T Awwad","doi":"10.1097/j.jcrs.0000000000001443","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the intrasubject repeatability of pyramidal aberrometer measurements in a sample of keratoconus and normal eyes.</p><p><strong>Setting: </strong>American University of Beirut Medical Center, Beirut, Lebanon.</p><p><strong>Design: </strong>Prospective comparative repeatability analysis.</p><p><strong>Methods: </strong>Study population: Keratoconus and normal eyes from adult patients. Observation procedures: Each eye was evaluated with 3 consecutive acquisitions using a pyramidal aberrometer. Main outcome measures: The repeatability of different ocular higher-order aberrations and lower-order aberrations (HOAs and LOAs, respectively), and Zernike coefficients down to the fifth order, was evaluated. Repeatability was assessed by within-subject SDs (Sw), repeatability limits ( r ), and intraclass correlation coefficients (ICCs), among other parameters.</p><p><strong>Results: </strong>72 keratoconus patients (72 eyes) and 76 normal patients (76 eyes) were included. In normal and keratoconus eyes, the ICC of total LOAs and HOAs, as well as each of the Zernike coefficients, was >0.9. The Sw for keratoconus eyes with mean maximal keratometry (Kmax) <50 diopters (D) was 0.1345 for total LOAs, 0.0619 for total HOAs, 0.0292 for horizontal coma, 0.0561 for vertical coma, and 0.0221 for spherical aberration as compared with 0.2696, 0.1486, 0.0972, 0.1497, and 0.0757 for keratoconus eyes with Kmax ≥50 D. Similar trend of better repeatability for grade 1 keratoconus and HOAs <2 D as compared with grades 2 and 3 keratoconus and eyes with HOAs >2 D were also noted.</p><p><strong>Conclusions: </strong>Ocular aberrometer measurements generated by high definition pyramidal aberrometers have high repeatability in both normal and mild keratoconus eyes and moderate repeatability, yet still clinically acceptable, in advanced keratoconus. This is of particular importance in ocular wavefront-guided treatments.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":"739-745"},"PeriodicalIF":2.6000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Repeatability of pyramidal aberrometer measurements in keratoconus and normal eyes.\",\"authors\":\"Perla Ibrahim, Jad F Assaf, Romy Bejjani, Julien Torbey, Madeleine Yehia, Saleh Bahir Al-Ulloom, Shady T Awwad\",\"doi\":\"10.1097/j.jcrs.0000000000001443\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the intrasubject repeatability of pyramidal aberrometer measurements in a sample of keratoconus and normal eyes.</p><p><strong>Setting: </strong>American University of Beirut Medical Center, Beirut, Lebanon.</p><p><strong>Design: </strong>Prospective comparative repeatability analysis.</p><p><strong>Methods: </strong>Study population: Keratoconus and normal eyes from adult patients. Observation procedures: Each eye was evaluated with 3 consecutive acquisitions using a pyramidal aberrometer. Main outcome measures: The repeatability of different ocular higher-order aberrations and lower-order aberrations (HOAs and LOAs, respectively), and Zernike coefficients down to the fifth order, was evaluated. Repeatability was assessed by within-subject SDs (Sw), repeatability limits ( r ), and intraclass correlation coefficients (ICCs), among other parameters.</p><p><strong>Results: </strong>72 keratoconus patients (72 eyes) and 76 normal patients (76 eyes) were included. In normal and keratoconus eyes, the ICC of total LOAs and HOAs, as well as each of the Zernike coefficients, was >0.9. The Sw for keratoconus eyes with mean maximal keratometry (Kmax) <50 diopters (D) was 0.1345 for total LOAs, 0.0619 for total HOAs, 0.0292 for horizontal coma, 0.0561 for vertical coma, and 0.0221 for spherical aberration as compared with 0.2696, 0.1486, 0.0972, 0.1497, and 0.0757 for keratoconus eyes with Kmax ≥50 D. Similar trend of better repeatability for grade 1 keratoconus and HOAs <2 D as compared with grades 2 and 3 keratoconus and eyes with HOAs >2 D were also noted.</p><p><strong>Conclusions: </strong>Ocular aberrometer measurements generated by high definition pyramidal aberrometers have high repeatability in both normal and mild keratoconus eyes and moderate repeatability, yet still clinically acceptable, in advanced keratoconus. This is of particular importance in ocular wavefront-guided treatments.</p>\",\"PeriodicalId\":15214,\"journal\":{\"name\":\"Journal of cataract and refractive surgery\",\"volume\":\" \",\"pages\":\"739-745\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of cataract and refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/j.jcrs.0000000000001443\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001443","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Methods: Study population: Keratoconus and normal eyes from adult patients. Observation procedures: Each eye was evaluated with 3 consecutive acquisitions using a pyramidal aberrometer. Main outcome measures: The repeatability of different ocular higher-order aberrations and lower-order aberrations (HOAs and LOAs, respectively), and Zernike coefficients down to the fifth order, was evaluated. Repeatability was assessed by within-subject SDs (Sw), repeatability limits ( r ), and intraclass correlation coefficients (ICCs), among other parameters.
Results: 72 keratoconus patients (72 eyes) and 76 normal patients (76 eyes) were included. In normal and keratoconus eyes, the ICC of total LOAs and HOAs, as well as each of the Zernike coefficients, was >0.9. The Sw for keratoconus eyes with mean maximal keratometry (Kmax) <50 diopters (D) was 0.1345 for total LOAs, 0.0619 for total HOAs, 0.0292 for horizontal coma, 0.0561 for vertical coma, and 0.0221 for spherical aberration as compared with 0.2696, 0.1486, 0.0972, 0.1497, and 0.0757 for keratoconus eyes with Kmax ≥50 D. Similar trend of better repeatability for grade 1 keratoconus and HOAs <2 D as compared with grades 2 and 3 keratoconus and eyes with HOAs >2 D were also noted.
Conclusions: Ocular aberrometer measurements generated by high definition pyramidal aberrometers have high repeatability in both normal and mild keratoconus eyes and moderate repeatability, yet still clinically acceptable, in advanced keratoconus. This is of particular importance in ocular wavefront-guided treatments.
期刊介绍:
The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS).
JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.