{"title":"使用 15O - 水的心电图门控动态心肌正电子发射计算机(ECG-gated dynamic myocardial PET)估算缺血性心肌病损中的可灌注组织比例和心肌血流储备的改进。","authors":"Ayaka Maruo, Keiichi Magota, Yamato Munakata, Kenji Hirata, Chietsugu Katoh","doi":"10.1007/s12149-024-01913-9","DOIUrl":null,"url":null,"abstract":"<div><h3>Objective</h3><p>Perfusable tissue fraction (PTF) and myocardial flow reserve (MFR) from <sup>15</sup>O-water dynamic positron emission tomography (PET) are parameters of myocardial viability. However, myocardial motion causes errors in these values. We aimed to develop accurate estimation of PTF and MFR in ischemic lesions using an electro-cardiogram (ECG)-gated dynamic myocardial PET with <sup>15</sup>O-water.</p><h3>Methods</h3><p>Twenty-seven patients with ischemic heart disease were enrolled. All patients underwent percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). List mode 3D PET data and ECG signals were acquired using Philips Gemini TF64 instrument. For each scan, 500 MBq of <sup>15</sup>O-water was infused slowly for 2 min, and the dynamic data were scanned for 6 min. Both non-gated dynamic images and ECG-gated diastolic dynamic images were reconstructed. On the myocardial PET images of each patient, the entire myocardial region of interest (ROI) was set and divided into 17 segments. Myocardial blood flow in the resting state (rest MBF), hyperemic state (stress MBF), PTF, and MFR in each segment were estimated from both non-gated and ECG-gated dynamic PET images. Coronary arteriograms were obtained for all patients. In total, 128 normal segments without stenosis and 50 ischemic segments with > 90% stenosis were evaluated.</p><h3>Results</h3><p>In the ischemic myocardial segments, the PTF with ECG-gated PET was estimated as significantly lower than that with non-gated PET (0.63 ± 0.09 vs. 0.72 ± 0.08 [mL/mL], p < 0.001). The ECG-gated PET estimated a significantly lower PTF in the ischemic segments than in the normal segments (0.63 ± 0.09 vs. 0.67 ± 0.07 [mL/mL], p < 0.01). In the normal segments, the ECG-gated PET detected no significant difference in MFR compared with those from the non-gated PET (2.15 ± 0.76 vs. 2.24 ± 0.79, p = 0.28). However, in the ischemic myocardial segments, the MFR with ECG-gated PET was estimated as significantly lower than that with the non-gated PET (1.23 ± 0.29 vs. 1.69 ± 0.71, p < 0.001). The ECG-gated PET presented a significantly higher inter-observer reproducibility of PTF and rest MBF than the non-gated PET (p < 0.01). Neither stress MBF nor MFR yielded significant differences in inter-observer reproducibility between the ECG-gated and non-gated PET.</p><h3>Conclusions</h3><p>The ECG-gated dynamic <sup>15</sup>O-water PET suppressed the myocardial motion effect and resulted in a lower PTF and MFR in ischemic myocardial lesions than the non-gated PET. The ECG-gated PET seemed to be better than the conventional non-gated dynamic PET for the detection of ischemic myocardial lesion.</p></div>","PeriodicalId":8007,"journal":{"name":"Annals of Nuclear Medicine","volume":"38 5","pages":"369 - 381"},"PeriodicalIF":2.5000,"publicationDate":"2024-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improvement in the estimation of perfusable tissue fraction and myocardial flow reserve in the ischemic myocardial lesions using ECG-gated dynamic myocardial PET with 15O-water\",\"authors\":\"Ayaka Maruo, Keiichi Magota, Yamato Munakata, Kenji Hirata, Chietsugu Katoh\",\"doi\":\"10.1007/s12149-024-01913-9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objective</h3><p>Perfusable tissue fraction (PTF) and myocardial flow reserve (MFR) from <sup>15</sup>O-water dynamic positron emission tomography (PET) are parameters of myocardial viability. However, myocardial motion causes errors in these values. We aimed to develop accurate estimation of PTF and MFR in ischemic lesions using an electro-cardiogram (ECG)-gated dynamic myocardial PET with <sup>15</sup>O-water.</p><h3>Methods</h3><p>Twenty-seven patients with ischemic heart disease were enrolled. All patients underwent percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). List mode 3D PET data and ECG signals were acquired using Philips Gemini TF64 instrument. For each scan, 500 MBq of <sup>15</sup>O-water was infused slowly for 2 min, and the dynamic data were scanned for 6 min. Both non-gated dynamic images and ECG-gated diastolic dynamic images were reconstructed. On the myocardial PET images of each patient, the entire myocardial region of interest (ROI) was set and divided into 17 segments. Myocardial blood flow in the resting state (rest MBF), hyperemic state (stress MBF), PTF, and MFR in each segment were estimated from both non-gated and ECG-gated dynamic PET images. Coronary arteriograms were obtained for all patients. In total, 128 normal segments without stenosis and 50 ischemic segments with > 90% stenosis were evaluated.</p><h3>Results</h3><p>In the ischemic myocardial segments, the PTF with ECG-gated PET was estimated as significantly lower than that with non-gated PET (0.63 ± 0.09 vs. 0.72 ± 0.08 [mL/mL], p < 0.001). The ECG-gated PET estimated a significantly lower PTF in the ischemic segments than in the normal segments (0.63 ± 0.09 vs. 0.67 ± 0.07 [mL/mL], p < 0.01). In the normal segments, the ECG-gated PET detected no significant difference in MFR compared with those from the non-gated PET (2.15 ± 0.76 vs. 2.24 ± 0.79, p = 0.28). However, in the ischemic myocardial segments, the MFR with ECG-gated PET was estimated as significantly lower than that with the non-gated PET (1.23 ± 0.29 vs. 1.69 ± 0.71, p < 0.001). The ECG-gated PET presented a significantly higher inter-observer reproducibility of PTF and rest MBF than the non-gated PET (p < 0.01). Neither stress MBF nor MFR yielded significant differences in inter-observer reproducibility between the ECG-gated and non-gated PET.</p><h3>Conclusions</h3><p>The ECG-gated dynamic <sup>15</sup>O-water PET suppressed the myocardial motion effect and resulted in a lower PTF and MFR in ischemic myocardial lesions than the non-gated PET. The ECG-gated PET seemed to be better than the conventional non-gated dynamic PET for the detection of ischemic myocardial lesion.</p></div>\",\"PeriodicalId\":8007,\"journal\":{\"name\":\"Annals of Nuclear Medicine\",\"volume\":\"38 5\",\"pages\":\"369 - 381\"},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-03-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Nuclear Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s12149-024-01913-9\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Nuclear Medicine","FirstCategoryId":"3","ListUrlMain":"https://link.springer.com/article/10.1007/s12149-024-01913-9","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0
摘要
目的:15O-水动态正电子发射断层扫描(PET)得出的可灌注组织分数(PTF)和心肌血流储备(MFR)是心肌活力的参数。然而,心肌运动会导致这些数值出现误差。我们的目的是利用心电图(ECG)门控的 15O 水动态心肌正电子发射断层扫描准确估计缺血性病变的 PTF 和 MFR:方法:共招募了 27 名缺血性心脏病患者。所有患者均接受了经皮冠状动脉介入治疗(PCI)或冠状动脉旁路移植术(CABG)。使用飞利浦 Gemini TF64 仪器采集了列表模式三维 PET 数据和心电图信号。每次扫描时,缓慢注入500 MBq的15O-水2分钟,动态数据扫描6分钟。对非门控动态图像和心电图门控舒张动态图像进行了重建。在每位患者的心肌 PET 图像上,设置了整个心肌感兴趣区(ROI),并将其划分为 17 个区段。根据非门控和心电图门控动态 PET 图像估算出每个节段的静息状态(静息 MBF)、充血状态(应激 MBF)、PTF 和 MFR。所有患者都获得了冠状动脉造影。共评估了 128 个无狭窄的正常节段和 50 个狭窄程度大于 90% 的缺血节段:结果:在缺血心肌区段,心电图门控 PET 估测的 PTF 明显低于非门控 PET(0.63 ± 0.09 vs. 0.72 ± 0.08 [mL/mL],p 结论:在缺血心肌区段,心电图门控动态 15O与非门控 PET 相比,心电图门控动态 15O 水 PET 可抑制心肌运动效应,使缺血性心肌病变的 PTF 和 MFR 更低。在检测缺血性心肌病变方面,心电图门控 PET 似乎优于传统的非门控动态 PET。
Improvement in the estimation of perfusable tissue fraction and myocardial flow reserve in the ischemic myocardial lesions using ECG-gated dynamic myocardial PET with 15O-water
Objective
Perfusable tissue fraction (PTF) and myocardial flow reserve (MFR) from 15O-water dynamic positron emission tomography (PET) are parameters of myocardial viability. However, myocardial motion causes errors in these values. We aimed to develop accurate estimation of PTF and MFR in ischemic lesions using an electro-cardiogram (ECG)-gated dynamic myocardial PET with 15O-water.
Methods
Twenty-seven patients with ischemic heart disease were enrolled. All patients underwent percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG). List mode 3D PET data and ECG signals were acquired using Philips Gemini TF64 instrument. For each scan, 500 MBq of 15O-water was infused slowly for 2 min, and the dynamic data were scanned for 6 min. Both non-gated dynamic images and ECG-gated diastolic dynamic images were reconstructed. On the myocardial PET images of each patient, the entire myocardial region of interest (ROI) was set and divided into 17 segments. Myocardial blood flow in the resting state (rest MBF), hyperemic state (stress MBF), PTF, and MFR in each segment were estimated from both non-gated and ECG-gated dynamic PET images. Coronary arteriograms were obtained for all patients. In total, 128 normal segments without stenosis and 50 ischemic segments with > 90% stenosis were evaluated.
Results
In the ischemic myocardial segments, the PTF with ECG-gated PET was estimated as significantly lower than that with non-gated PET (0.63 ± 0.09 vs. 0.72 ± 0.08 [mL/mL], p < 0.001). The ECG-gated PET estimated a significantly lower PTF in the ischemic segments than in the normal segments (0.63 ± 0.09 vs. 0.67 ± 0.07 [mL/mL], p < 0.01). In the normal segments, the ECG-gated PET detected no significant difference in MFR compared with those from the non-gated PET (2.15 ± 0.76 vs. 2.24 ± 0.79, p = 0.28). However, in the ischemic myocardial segments, the MFR with ECG-gated PET was estimated as significantly lower than that with the non-gated PET (1.23 ± 0.29 vs. 1.69 ± 0.71, p < 0.001). The ECG-gated PET presented a significantly higher inter-observer reproducibility of PTF and rest MBF than the non-gated PET (p < 0.01). Neither stress MBF nor MFR yielded significant differences in inter-observer reproducibility between the ECG-gated and non-gated PET.
Conclusions
The ECG-gated dynamic 15O-water PET suppressed the myocardial motion effect and resulted in a lower PTF and MFR in ischemic myocardial lesions than the non-gated PET. The ECG-gated PET seemed to be better than the conventional non-gated dynamic PET for the detection of ischemic myocardial lesion.
期刊介绍:
Annals of Nuclear Medicine is an official journal of the Japanese Society of Nuclear Medicine. It develops the appropriate application of radioactive substances and stable nuclides in the field of medicine.
The journal promotes the exchange of ideas and information and research in nuclear medicine and includes the medical application of radionuclides and related subjects. It presents original articles, short communications, reviews and letters to the editor.