Søren Gam, Anders K. Petz, Lukas R. Bjerre, Jeppe Bøgild, Anders B. Nielsen, Rikke N. Sørensen, Mikkel I. Kolind, Bibi Gram, Stinus Hansen, Per Aagaard
{"title":"对符合减肥手术条件的成人肥胖症患者进行下肢肌力评估的疗程间可靠性。","authors":"Søren Gam, Anders K. Petz, Lukas R. Bjerre, Jeppe Bøgild, Anders B. Nielsen, Rikke N. Sørensen, Mikkel I. Kolind, Bibi Gram, Stinus Hansen, Per Aagaard","doi":"10.1111/cpf.12876","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Background</h3>\n \n <p>The aim of this study was to examine the test−retest reliability in lower limb muscle strength and rate of torque development (RTD) using isokinetic dynamometry in adults with obesity, with a body mass index (BMI) ≥ 35 kg/m<sup>2</sup>.</p>\n </section>\n \n <section>\n \n <h3> Method</h3>\n \n <p>Thirty-two adults with a BMI of 43.8 ± 6.6 kg/m<sup>2</sup> eligible for bariatric surgery were enroled in the study. Isokinetic and isometric knee extensor (KE) and flexor (KF) strength were assessed in an isokinetic dynamometer (Biodex 4) during three test sessions separated by 3−7 days.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>There were no statistical differences in peak KE and KF torque for any test modalities between sessions. Intraclass correlation (ICC) was 0.91−0.94 between sessions 1 and 2 and 0.94−0.97 between sessions 2 and 3. Standard error of measurement (SEM%) and coefficient of variation (CV) ranged across test sessions from 4.3% to 7.3%. KE RTD showed high test−retest reliability following familiarization, with ICC, CV and SEM% values ranging from 0.84 to 0.90, 13.3%−20.3% and 14.6%−24.9%, respectively.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>Maximal lower limb muscle strength measured by isokinetic dynamometry showed excellent test−retest reliability manifested by small measurement errors and low CV. Reliability was slightly improved by including a familiarization session. KE RTD but not KF RTD demonstrated high test−retest reliability following familiarization. The present data indicate that isokinetic dynamometry can be used to detect even small changes in lower limb muscle strength in adults with obesity.</p>\n </section>\n </div>","PeriodicalId":10504,"journal":{"name":"Clinical Physiology and Functional Imaging","volume":"44 4","pages":"303-312"},"PeriodicalIF":1.3000,"publicationDate":"2024-03-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cpf.12876","citationCount":"0","resultStr":"{\"title\":\"Intersession reliability of lower limb muscle strength assessments in adults with obesity eligible for bariatric surgery\",\"authors\":\"Søren Gam, Anders K. Petz, Lukas R. Bjerre, Jeppe Bøgild, Anders B. Nielsen, Rikke N. Sørensen, Mikkel I. Kolind, Bibi Gram, Stinus Hansen, Per Aagaard\",\"doi\":\"10.1111/cpf.12876\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Background</h3>\\n \\n <p>The aim of this study was to examine the test−retest reliability in lower limb muscle strength and rate of torque development (RTD) using isokinetic dynamometry in adults with obesity, with a body mass index (BMI) ≥ 35 kg/m<sup>2</sup>.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Method</h3>\\n \\n <p>Thirty-two adults with a BMI of 43.8 ± 6.6 kg/m<sup>2</sup> eligible for bariatric surgery were enroled in the study. Isokinetic and isometric knee extensor (KE) and flexor (KF) strength were assessed in an isokinetic dynamometer (Biodex 4) during three test sessions separated by 3−7 days.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>There were no statistical differences in peak KE and KF torque for any test modalities between sessions. Intraclass correlation (ICC) was 0.91−0.94 between sessions 1 and 2 and 0.94−0.97 between sessions 2 and 3. Standard error of measurement (SEM%) and coefficient of variation (CV) ranged across test sessions from 4.3% to 7.3%. KE RTD showed high test−retest reliability following familiarization, with ICC, CV and SEM% values ranging from 0.84 to 0.90, 13.3%−20.3% and 14.6%−24.9%, respectively.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>Maximal lower limb muscle strength measured by isokinetic dynamometry showed excellent test−retest reliability manifested by small measurement errors and low CV. Reliability was slightly improved by including a familiarization session. KE RTD but not KF RTD demonstrated high test−retest reliability following familiarization. The present data indicate that isokinetic dynamometry can be used to detect even small changes in lower limb muscle strength in adults with obesity.</p>\\n </section>\\n </div>\",\"PeriodicalId\":10504,\"journal\":{\"name\":\"Clinical Physiology and Functional Imaging\",\"volume\":\"44 4\",\"pages\":\"303-312\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-03-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1111/cpf.12876\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical Physiology and Functional Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/cpf.12876\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PHYSIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Physiology and Functional Imaging","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/cpf.12876","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PHYSIOLOGY","Score":null,"Total":0}
Intersession reliability of lower limb muscle strength assessments in adults with obesity eligible for bariatric surgery
Background
The aim of this study was to examine the test−retest reliability in lower limb muscle strength and rate of torque development (RTD) using isokinetic dynamometry in adults with obesity, with a body mass index (BMI) ≥ 35 kg/m2.
Method
Thirty-two adults with a BMI of 43.8 ± 6.6 kg/m2 eligible for bariatric surgery were enroled in the study. Isokinetic and isometric knee extensor (KE) and flexor (KF) strength were assessed in an isokinetic dynamometer (Biodex 4) during three test sessions separated by 3−7 days.
Results
There were no statistical differences in peak KE and KF torque for any test modalities between sessions. Intraclass correlation (ICC) was 0.91−0.94 between sessions 1 and 2 and 0.94−0.97 between sessions 2 and 3. Standard error of measurement (SEM%) and coefficient of variation (CV) ranged across test sessions from 4.3% to 7.3%. KE RTD showed high test−retest reliability following familiarization, with ICC, CV and SEM% values ranging from 0.84 to 0.90, 13.3%−20.3% and 14.6%−24.9%, respectively.
Conclusion
Maximal lower limb muscle strength measured by isokinetic dynamometry showed excellent test−retest reliability manifested by small measurement errors and low CV. Reliability was slightly improved by including a familiarization session. KE RTD but not KF RTD demonstrated high test−retest reliability following familiarization. The present data indicate that isokinetic dynamometry can be used to detect even small changes in lower limb muscle strength in adults with obesity.
期刊介绍:
Clinical Physiology and Functional Imaging publishes reports on clinical and experimental research pertinent to human physiology in health and disease. The scope of the Journal is very broad, covering all aspects of the regulatory system in the cardiovascular, renal and pulmonary systems with special emphasis on methodological aspects. The focus for the journal is, however, work that has potential clinical relevance. The Journal also features review articles on recent front-line research within these fields of interest.
Covered by the major abstracting services including Current Contents and Science Citation Index, Clinical Physiology and Functional Imaging plays an important role in providing effective and productive communication among clinical physiologists world-wide.