加速级电极电压对零磁点可调双级霍尔效应推进器性能的影响

Long Chen, Weifu Gao, Zuojun Cui, Ping Duan, Xuesong Xu, Zichen Kan, Congqi Tan, Junyu Chen
{"title":"加速级电极电压对零磁点可调双级霍尔效应推进器性能的影响","authors":"Long Chen, Weifu Gao, Zuojun Cui, Ping Duan, Xuesong Xu, Zichen Kan, Congqi Tan, Junyu Chen","doi":"10.1088/2058-6272/ad2fac","DOIUrl":null,"url":null,"abstract":"\n The configuration of electrode voltage and zero magnetic point position has a significant impact on the performance of the double-stage Hall effect thruster. A 2D-3V model is established based on the two-magnetic peak type double-stage Hall thruster configuration, and a particle-in-cell simulation is carried out to investigate the influences of both acceleration electrode voltage value and zero magnetic point position on the thruster discharge characteristics and performances. The results indicate that increasing the acceleration voltage leads to a larger potential drop in the acceleration stage, allowing ions to gain higher energy, while electrons are easily absorbed by the intermediate electrode, resulting in a decrease in the anode current and ionization rate. When the acceleration voltage reaches 500 V, the thrust and efficiency are maximized, resulting in a 15% increase in efficiency. After the acceleration voltage exceeds 500 V, a potential barrier forms within the channel, leading to a decrease in thruster efficiency. Further study shows that as the second zero magnetic point moves towards the outlet of the channel, more electrons easily traverse the zero magnetic field region, participating in the ionization. The increase in the ionization rate leads to a gradual enhancement in both thrust and efficiency.","PeriodicalId":506986,"journal":{"name":"Plasma Science and Technology","volume":"11 12","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-03-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of acceleration stage electrode voltage on the performance of double-stage Hall effect thruster with adjustable zero magnetic point\",\"authors\":\"Long Chen, Weifu Gao, Zuojun Cui, Ping Duan, Xuesong Xu, Zichen Kan, Congqi Tan, Junyu Chen\",\"doi\":\"10.1088/2058-6272/ad2fac\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"\\n The configuration of electrode voltage and zero magnetic point position has a significant impact on the performance of the double-stage Hall effect thruster. A 2D-3V model is established based on the two-magnetic peak type double-stage Hall thruster configuration, and a particle-in-cell simulation is carried out to investigate the influences of both acceleration electrode voltage value and zero magnetic point position on the thruster discharge characteristics and performances. The results indicate that increasing the acceleration voltage leads to a larger potential drop in the acceleration stage, allowing ions to gain higher energy, while electrons are easily absorbed by the intermediate electrode, resulting in a decrease in the anode current and ionization rate. When the acceleration voltage reaches 500 V, the thrust and efficiency are maximized, resulting in a 15% increase in efficiency. After the acceleration voltage exceeds 500 V, a potential barrier forms within the channel, leading to a decrease in thruster efficiency. Further study shows that as the second zero magnetic point moves towards the outlet of the channel, more electrons easily traverse the zero magnetic field region, participating in the ionization. The increase in the ionization rate leads to a gradual enhancement in both thrust and efficiency.\",\"PeriodicalId\":506986,\"journal\":{\"name\":\"Plasma Science and Technology\",\"volume\":\"11 12\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-03-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Plasma Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/2058-6272/ad2fac\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Plasma Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/2058-6272/ad2fac","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电极电压和零磁点位置的配置对双级霍尔效应推进器的性能有重要影响。基于双磁峰型双级霍尔推进器构型,建立了 2D-3V 模型,并进行了粒子入胞仿真,研究了加速电极电压值和零磁点位置对推进器放电特性和性能的影响。结果表明,增加加速电压会导致加速级电位下降,使离子获得更高的能量,而电子则容易被中间电极吸收,导致阳极电流和电离率下降。当加速电压达到 500 V 时,推力和效率达到最大化,从而使效率提高 15%。加速电压超过 500 V 后,通道内形成势垒,导致推进器效率下降。进一步的研究表明,当第二个零磁点向通道出口移动时,更多的电子容易穿越零磁场区域,参与电离。电离率的增加导致推力和效率逐渐提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Influence of acceleration stage electrode voltage on the performance of double-stage Hall effect thruster with adjustable zero magnetic point
The configuration of electrode voltage and zero magnetic point position has a significant impact on the performance of the double-stage Hall effect thruster. A 2D-3V model is established based on the two-magnetic peak type double-stage Hall thruster configuration, and a particle-in-cell simulation is carried out to investigate the influences of both acceleration electrode voltage value and zero magnetic point position on the thruster discharge characteristics and performances. The results indicate that increasing the acceleration voltage leads to a larger potential drop in the acceleration stage, allowing ions to gain higher energy, while electrons are easily absorbed by the intermediate electrode, resulting in a decrease in the anode current and ionization rate. When the acceleration voltage reaches 500 V, the thrust and efficiency are maximized, resulting in a 15% increase in efficiency. After the acceleration voltage exceeds 500 V, a potential barrier forms within the channel, leading to a decrease in thruster efficiency. Further study shows that as the second zero magnetic point moves towards the outlet of the channel, more electrons easily traverse the zero magnetic field region, participating in the ionization. The increase in the ionization rate leads to a gradual enhancement in both thrust and efficiency.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信