{"title":"用 SiO 2 -CuO-GLUCOSE 氧化酶薄膜改性的碳丝网印刷电极,用于以细菌为指示系统的毒性评估","authors":"Marko Kuznetsov,&nbsp;Oksana Tananaiko,&nbsp;Michael Gelinsky,&nbsp;Max von Witzleben,&nbsp;David Kilian,&nbsp;Anastasia Lunyo,&nbsp;Vita Saska,&nbsp;Katerina Dzhihirei,&nbsp;Vladyslav Lisnyak,&nbsp;Liudmyla Grischenko,&nbsp;Serhiy Kondratenko,&nbsp;Liudmyla Rieznichenko,&nbsp;Tamara Gruzina,&nbsp;Svitlana Dybkova","doi":"10.1002/elan.202300404","DOIUrl":null,"url":null,"abstract":"<p>A portable voltammetric sensor for toxicity assessment was developed based on a screen-printed carbon electrode modified with SiO<sub>2</sub>-CuO-glucose oxidase (GOx) film. The method is based on the detection of the metabolic activity of <i>E. coli</i> towards glucose as an indicator systems in the presence of antiseptic drugs as model toxic compounds. CuO particles exhibited catalytic activity toward hydrogen peroxide produced by the GOx-induced oxidation of glucose. A well-defined reduction peak was registered at <i>E</i>=−0.50 V (<i>vs</i>. Ag/AgCl). The metabolism of glucose by <i>E. coli</i> resulted in a decrease in analytical signal of glucose with the increasing bacteria content in the range of 0.8×10<sup>9</sup>–5.0×10<sup>9</sup> CFU mL<sup>−1</sup> with a calculated limit of detection (LOD) of 0.59×10<sup>9</sup> CFU mL<sup>−1</sup>. To evaluate the effect of antiseptics the biosensor was tested in <i>E. coli</i> solution with chlorhexidine (CHD) or decamethoxine (DMT). A linear dependence of glucose consumption by <i>E. coli</i> solution on the antiseptic concentration was obtained in the range of 3.0–12.0 μg mL<sup>−1</sup> for CHG and 1.0–12.0 μg mL<sup>−1</sup> for DMT, respectively. The developed third generation biosensor showed satisfactory stability and reproducibility of the analytical response. A modified electrode can be used for at least two months.</p>","PeriodicalId":162,"journal":{"name":"Electroanalysis","volume":"36 8","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2024-03-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Carbon screen-printed electrodes modified with SiO2-CuO-glucose oxidase film for toxicity assessment using bacteria as indicator systems\",\"authors\":\"Marko Kuznetsov,&nbsp;Oksana Tananaiko,&nbsp;Michael Gelinsky,&nbsp;Max von Witzleben,&nbsp;David Kilian,&nbsp;Anastasia Lunyo,&nbsp;Vita Saska,&nbsp;Katerina Dzhihirei,&nbsp;Vladyslav Lisnyak,&nbsp;Liudmyla Grischenko,&nbsp;Serhiy Kondratenko,&nbsp;Liudmyla Rieznichenko,&nbsp;Tamara Gruzina,&nbsp;Svitlana Dybkova\",\"doi\":\"10.1002/elan.202300404\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A portable voltammetric sensor for toxicity assessment was developed based on a screen-printed carbon electrode modified with SiO<sub>2</sub>-CuO-glucose oxidase (GOx) film. The method is based on the detection of the metabolic activity of <i>E. coli</i> towards glucose as an indicator systems in the presence of antiseptic drugs as model toxic compounds. CuO particles exhibited catalytic activity toward hydrogen peroxide produced by the GOx-induced oxidation of glucose. A well-defined reduction peak was registered at <i>E</i>=−0.50 V (<i>vs</i>. Ag/AgCl). The metabolism of glucose by <i>E. coli</i> resulted in a decrease in analytical signal of glucose with the increasing bacteria content in the range of 0.8×10<sup>9</sup>–5.0×10<sup>9</sup> CFU mL<sup>−1</sup> with a calculated limit of detection (LOD) of 0.59×10<sup>9</sup> CFU mL<sup>−1</sup>. To evaluate the effect of antiseptics the biosensor was tested in <i>E. coli</i> solution with chlorhexidine (CHD) or decamethoxine (DMT). A linear dependence of glucose consumption by <i>E. coli</i> solution on the antiseptic concentration was obtained in the range of 3.0–12.0 μg mL<sup>−1</sup> for CHG and 1.0–12.0 μg mL<sup>−1</sup> for DMT, respectively. The developed third generation biosensor showed satisfactory stability and reproducibility of the analytical response. A modified electrode can be used for at least two months.</p>\",\"PeriodicalId\":162,\"journal\":{\"name\":\"Electroanalysis\",\"volume\":\"36 8\",\"pages\":\"\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-03-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Electroanalysis\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/elan.202300404\",\"RegionNum\":3,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Electroanalysis","FirstCategoryId":"92","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/elan.202300404","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

na
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Carbon screen-printed electrodes modified with SiO2-CuO-glucose oxidase film for toxicity assessment using bacteria as indicator systems

A portable voltammetric sensor for toxicity assessment was developed based on a screen-printed carbon electrode modified with SiO2-CuO-glucose oxidase (GOx) film. The method is based on the detection of the metabolic activity of E. coli towards glucose as an indicator systems in the presence of antiseptic drugs as model toxic compounds. CuO particles exhibited catalytic activity toward hydrogen peroxide produced by the GOx-induced oxidation of glucose. A well-defined reduction peak was registered at E=−0.50 V (vs. Ag/AgCl). The metabolism of glucose by E. coli resulted in a decrease in analytical signal of glucose with the increasing bacteria content in the range of 0.8×109–5.0×109 CFU mL−1 with a calculated limit of detection (LOD) of 0.59×109 CFU mL−1. To evaluate the effect of antiseptics the biosensor was tested in E. coli solution with chlorhexidine (CHD) or decamethoxine (DMT). A linear dependence of glucose consumption by E. coli solution on the antiseptic concentration was obtained in the range of 3.0–12.0 μg mL−1 for CHG and 1.0–12.0 μg mL−1 for DMT, respectively. The developed third generation biosensor showed satisfactory stability and reproducibility of the analytical response. A modified electrode can be used for at least two months.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Electroanalysis
Electroanalysis 化学-电化学
CiteScore
6.00
自引率
3.30%
发文量
222
审稿时长
2.4 months
期刊介绍: Electroanalysis is an international, peer-reviewed journal covering all branches of electroanalytical chemistry, including both fundamental and application papers as well as reviews dealing with new electrochemical sensors and biosensors, nanobioelectronics devices, analytical voltammetry, potentiometry, new electrochemical detection schemes based on novel nanomaterials, fuel cells and biofuel cells, and important practical applications. Serving as a vital communication link between the research labs and the field, Electroanalysis helps you to quickly adapt the latest innovations into practical clinical, environmental, food analysis, industrial and energy-related applications. Electroanalysis provides the most comprehensive coverage of the field and is the number one source for information on electroanalytical chemistry, electrochemical sensors and biosensors and fuel/biofuel cells.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信