Katie Diekhans, Jihau Yu, Megan Farley, Luke N Rodda
{"title":"利用 LC-MS-MS 分析血液和尿液中 250 多种新型合成阿片类药物和恶嗪。","authors":"Katie Diekhans, Jihau Yu, Megan Farley, Luke N Rodda","doi":"10.1093/jat/bkae009","DOIUrl":null,"url":null,"abstract":"<p><p>Novel Synthetic Opioids (NSO) are frequently found in postmortem (PM) and human performance (HP) forensic toxicology casework, resulting in impairment and fatal overdoses. Developing a broad NSO method benefits public health, as it can be used to identify trends in potent opioid use to develop risk management programs. This project aimed to design a comprehensive, rapid and routine method for the selective analysis of over 250 novel synthetic opioids in blood and urine. This method rapidly extracted 150 µL of blood or urine via protein precipitation followed by size-exclusion filtration, evaporation and reconstitution. Separation and data acquisition were achieved on a 12 min LC-MS-MS method using an F5 column. Data processing was expedited with a custom built-in query created in-house that automated processing and enhanced quality assurance. Validation according to ASB/ANSI Standard 036 was performed and applicability of the method was assessed using proficiency test and authentic casework samples. Assessed in blood and urine qualitatively were 261 unique analytes including fentanyl analogs (fentalogs), nitazenes and other miscellaneous synthetic opioids. As 59 isomeric target analytes were placed into groups due to co-elution, there were 202 distinct acquired targets or target - groups. To demonstrate applicability, 27 proficiency test blood samples received over an approximate 4-year period were analyzed with 126 expected results assessed comprising 25 unique target analytes. Additionally, 617 fatal accidental overdoses within San Francisco in 2022 were retroactively analyzed by this method with almost 10% of cases containing a new NSO substance(s). Such trends and NSO substances were previously unknown in this community.</p>","PeriodicalId":14905,"journal":{"name":"Journal of analytical toxicology","volume":" ","pages":"150-164"},"PeriodicalIF":2.3000,"publicationDate":"2024-03-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of over 250 novel synthetic opioids and xylazine by LC-MS-MS in blood and urine.\",\"authors\":\"Katie Diekhans, Jihau Yu, Megan Farley, Luke N Rodda\",\"doi\":\"10.1093/jat/bkae009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Novel Synthetic Opioids (NSO) are frequently found in postmortem (PM) and human performance (HP) forensic toxicology casework, resulting in impairment and fatal overdoses. Developing a broad NSO method benefits public health, as it can be used to identify trends in potent opioid use to develop risk management programs. This project aimed to design a comprehensive, rapid and routine method for the selective analysis of over 250 novel synthetic opioids in blood and urine. This method rapidly extracted 150 µL of blood or urine via protein precipitation followed by size-exclusion filtration, evaporation and reconstitution. Separation and data acquisition were achieved on a 12 min LC-MS-MS method using an F5 column. Data processing was expedited with a custom built-in query created in-house that automated processing and enhanced quality assurance. Validation according to ASB/ANSI Standard 036 was performed and applicability of the method was assessed using proficiency test and authentic casework samples. Assessed in blood and urine qualitatively were 261 unique analytes including fentanyl analogs (fentalogs), nitazenes and other miscellaneous synthetic opioids. As 59 isomeric target analytes were placed into groups due to co-elution, there were 202 distinct acquired targets or target - groups. To demonstrate applicability, 27 proficiency test blood samples received over an approximate 4-year period were analyzed with 126 expected results assessed comprising 25 unique target analytes. Additionally, 617 fatal accidental overdoses within San Francisco in 2022 were retroactively analyzed by this method with almost 10% of cases containing a new NSO substance(s). Such trends and NSO substances were previously unknown in this community.</p>\",\"PeriodicalId\":14905,\"journal\":{\"name\":\"Journal of analytical toxicology\",\"volume\":\" \",\"pages\":\"150-164\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-03-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of analytical toxicology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/jat/bkae009\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of analytical toxicology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/jat/bkae009","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Analysis of over 250 novel synthetic opioids and xylazine by LC-MS-MS in blood and urine.
Novel Synthetic Opioids (NSO) are frequently found in postmortem (PM) and human performance (HP) forensic toxicology casework, resulting in impairment and fatal overdoses. Developing a broad NSO method benefits public health, as it can be used to identify trends in potent opioid use to develop risk management programs. This project aimed to design a comprehensive, rapid and routine method for the selective analysis of over 250 novel synthetic opioids in blood and urine. This method rapidly extracted 150 µL of blood or urine via protein precipitation followed by size-exclusion filtration, evaporation and reconstitution. Separation and data acquisition were achieved on a 12 min LC-MS-MS method using an F5 column. Data processing was expedited with a custom built-in query created in-house that automated processing and enhanced quality assurance. Validation according to ASB/ANSI Standard 036 was performed and applicability of the method was assessed using proficiency test and authentic casework samples. Assessed in blood and urine qualitatively were 261 unique analytes including fentanyl analogs (fentalogs), nitazenes and other miscellaneous synthetic opioids. As 59 isomeric target analytes were placed into groups due to co-elution, there were 202 distinct acquired targets or target - groups. To demonstrate applicability, 27 proficiency test blood samples received over an approximate 4-year period were analyzed with 126 expected results assessed comprising 25 unique target analytes. Additionally, 617 fatal accidental overdoses within San Francisco in 2022 were retroactively analyzed by this method with almost 10% of cases containing a new NSO substance(s). Such trends and NSO substances were previously unknown in this community.
期刊介绍:
The Journal of Analytical Toxicology (JAT) is an international toxicology journal devoted to the timely dissemination of scientific communications concerning potentially toxic substances and drug identification, isolation, and quantitation.
Since its inception in 1977, the Journal of Analytical Toxicology has striven to present state-of-the-art techniques used in toxicology labs. The peer-review process provided by the distinguished members of the Editorial Advisory Board ensures the high-quality and integrity of articles published in the Journal of Analytical Toxicology. Timely presentation of the latest toxicology developments is ensured through Technical Notes, Case Reports, and Letters to the Editor.