{"title":"分析埃塞俄比亚一家专科医院的临床实验室标本排斥率:两年文件回顾。","authors":"Teshiwal Deress, Yeshewas Abebaw, Yezena Esayas, Semegn Nebertu, Meseret Kinidie, Germaw Abebe, Biruk Bayleyegn","doi":"10.1093/ajcp/aqae019","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Accurate laboratory diagnosis is essential for effective patient care, but the rejection of specimens within laboratories can have serious consequences.</p><p><strong>Methods: </strong>A retrospective cross-sectional study was conducted from September to November 2021 at the University of Gondar Comprehensive Specialized Hospital laboratory. Two years of laboratory data were collected from laboratory log books and analyzed to determine trends in specimen rejection rates and identify potential reasons for those rejections.</p><p><strong>Results: </strong>We analyzed 114,439 specimens, of which 786 (0.70%) were rejected. The hematology service exhibited the highest rejection rate, at 273 (0.2%). The main reasons for specimen rejection were specimens without requests or requests without specimens (40.2%), poor smear preparation (12.3%), clotted specimens (11.3%), and labeling problems (8.0%).</p><p><strong>Conclusions: </strong>This study emphasized a significant incidence of specimen rejection, particularly in the hematology laboratory, underscoring the need for immediate implementation of corrective actions and preventive measures. Furthermore, conducting comprehensive larger-scale studies is recommended to deepen our understanding of and investigate the specific factors contributing to specimen rejection in greater detail.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analyzing clinical laboratory specimen rejection rates at a specialized hospital in Ethiopia: A 2-year document review.\",\"authors\":\"Teshiwal Deress, Yeshewas Abebaw, Yezena Esayas, Semegn Nebertu, Meseret Kinidie, Germaw Abebe, Biruk Bayleyegn\",\"doi\":\"10.1093/ajcp/aqae019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>Accurate laboratory diagnosis is essential for effective patient care, but the rejection of specimens within laboratories can have serious consequences.</p><p><strong>Methods: </strong>A retrospective cross-sectional study was conducted from September to November 2021 at the University of Gondar Comprehensive Specialized Hospital laboratory. Two years of laboratory data were collected from laboratory log books and analyzed to determine trends in specimen rejection rates and identify potential reasons for those rejections.</p><p><strong>Results: </strong>We analyzed 114,439 specimens, of which 786 (0.70%) were rejected. The hematology service exhibited the highest rejection rate, at 273 (0.2%). The main reasons for specimen rejection were specimens without requests or requests without specimens (40.2%), poor smear preparation (12.3%), clotted specimens (11.3%), and labeling problems (8.0%).</p><p><strong>Conclusions: </strong>This study emphasized a significant incidence of specimen rejection, particularly in the hematology laboratory, underscoring the need for immediate implementation of corrective actions and preventive measures. Furthermore, conducting comprehensive larger-scale studies is recommended to deepen our understanding of and investigate the specific factors contributing to specimen rejection in greater detail.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/ajcp/aqae019\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ajcp/aqae019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
Analyzing clinical laboratory specimen rejection rates at a specialized hospital in Ethiopia: A 2-year document review.
Objectives: Accurate laboratory diagnosis is essential for effective patient care, but the rejection of specimens within laboratories can have serious consequences.
Methods: A retrospective cross-sectional study was conducted from September to November 2021 at the University of Gondar Comprehensive Specialized Hospital laboratory. Two years of laboratory data were collected from laboratory log books and analyzed to determine trends in specimen rejection rates and identify potential reasons for those rejections.
Results: We analyzed 114,439 specimens, of which 786 (0.70%) were rejected. The hematology service exhibited the highest rejection rate, at 273 (0.2%). The main reasons for specimen rejection were specimens without requests or requests without specimens (40.2%), poor smear preparation (12.3%), clotted specimens (11.3%), and labeling problems (8.0%).
Conclusions: This study emphasized a significant incidence of specimen rejection, particularly in the hematology laboratory, underscoring the need for immediate implementation of corrective actions and preventive measures. Furthermore, conducting comprehensive larger-scale studies is recommended to deepen our understanding of and investigate the specific factors contributing to specimen rejection in greater detail.