数码印模与传统印模在陶瓷嵌体边缘贴合度方面的临床比较。

IF 2.7 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of Advanced Prosthodontics Pub Date : 2024-02-01 Epub Date: 2024-02-23 DOI:10.4047/jap.2024.16.1.57
Franklin Guillermo Vargas-Corral, Américo Ernesto Vargas-Corral, Miguel Angel Rodríguez-Valverde, Manuel Bravo, Juan Ignacio Rosales-Leal
{"title":"数码印模与传统印模在陶瓷嵌体边缘贴合度方面的临床比较。","authors":"Franklin Guillermo Vargas-Corral, Américo Ernesto Vargas-Corral, Miguel Angel Rodríguez-Valverde, Manuel Bravo, Juan Ignacio Rosales-Leal","doi":"10.4047/jap.2024.16.1.57","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this stuldy was to compare the clinical marginal fit of CAD-CAM inlays obtained from intraoral digital impression or addition silicone impression techniques.</p><p><strong>Materials and methods: </strong>The study included 31 inlays for prosthodontics purposes of 31 patients: 15 based on intraoral digital impressions (DI group); and 16 based on a conventional impression technique (CI group). Inlays included occlusal and a non-occlusal surface. Inlays were milled in ceramic. The inlay-teeth interface was replicated by placing each inlay in its corresponding uncemented clinical preparation and taking interface impressions with silicone material from occlusal and free surfaces. Interface analysis was made using white light confocal microscopy (WLCM) (scanning area: 694 × 510 µm<sup>2</sup>) from the impression samples. The gap size and the inlay overextension were measured from the microscopy topographies. For analytical purposes (i.e., 95-%-confidence intervals calculations and <i>P</i>-value calculations), the procedure REGRESS in SUDAAN was used to account for clustering (i.e., multiple measurements). For p-value calculation, the log transformation of the dependent variables was used to normalize the distributions.</p><p><strong>Results: </strong>Marginal fit values for occlusal and free surfaces were affected by the type of impression. There were no differences between surfaces (occlusal vs. free). Gap obtained for DI group was 164 ± 84 µm and that for CI group was 209 ± 104 µm, and there were statistical differences between them (<i>p</i> = .041). Mean overextension values were 60 ± 59 µm for DI group and 67 ± 73 µm for CI group, and there were no differences between then (<i>p</i> = .553).</p><p><strong>Conclusion: </strong>Digital impression achieved inlays with higher clinical marginal fit and performed better than the conventional silicone materials.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10917630/pdf/","citationCount":"0","resultStr":"{\"title\":\"Clinical comparison of marginal fit of ceramic inlays between digital and conventional impressions.\",\"authors\":\"Franklin Guillermo Vargas-Corral, Américo Ernesto Vargas-Corral, Miguel Angel Rodríguez-Valverde, Manuel Bravo, Juan Ignacio Rosales-Leal\",\"doi\":\"10.4047/jap.2024.16.1.57\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of this stuldy was to compare the clinical marginal fit of CAD-CAM inlays obtained from intraoral digital impression or addition silicone impression techniques.</p><p><strong>Materials and methods: </strong>The study included 31 inlays for prosthodontics purposes of 31 patients: 15 based on intraoral digital impressions (DI group); and 16 based on a conventional impression technique (CI group). Inlays included occlusal and a non-occlusal surface. Inlays were milled in ceramic. The inlay-teeth interface was replicated by placing each inlay in its corresponding uncemented clinical preparation and taking interface impressions with silicone material from occlusal and free surfaces. Interface analysis was made using white light confocal microscopy (WLCM) (scanning area: 694 × 510 µm<sup>2</sup>) from the impression samples. The gap size and the inlay overextension were measured from the microscopy topographies. For analytical purposes (i.e., 95-%-confidence intervals calculations and <i>P</i>-value calculations), the procedure REGRESS in SUDAAN was used to account for clustering (i.e., multiple measurements). For p-value calculation, the log transformation of the dependent variables was used to normalize the distributions.</p><p><strong>Results: </strong>Marginal fit values for occlusal and free surfaces were affected by the type of impression. There were no differences between surfaces (occlusal vs. free). Gap obtained for DI group was 164 ± 84 µm and that for CI group was 209 ± 104 µm, and there were statistical differences between them (<i>p</i> = .041). Mean overextension values were 60 ± 59 µm for DI group and 67 ± 73 µm for CI group, and there were no differences between then (<i>p</i> = .553).</p><p><strong>Conclusion: </strong>Digital impression achieved inlays with higher clinical marginal fit and performed better than the conventional silicone materials.</p>\",\"PeriodicalId\":51291,\"journal\":{\"name\":\"Journal of Advanced Prosthodontics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10917630/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4047/jap.2024.16.1.57\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/23 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4047/jap.2024.16.1.57","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/23 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在比较口内数字印模和硅胶印模技术获得的CAD-CAM嵌体的临床边缘密合度:研究包括 31 名患者的 31 枚用于修复目的的嵌体:其中 15 例采用口内数字印模(DI 组);16 例采用传统印模技术(CI 组)。嵌体包括咬合面和非咬合面。嵌体由陶瓷研磨而成。将每个嵌体放入相应的非粘结临床预备中,用硅胶材料在咬合面和游离面上取界面印模,复制嵌体与牙齿的界面。使用白光共聚焦显微镜(WLCM)(扫描区域:694 × 510 µm2)对印模样本进行界面分析。根据显微地形图测量了间隙大小和嵌体过伸程度。出于分析目的(即 95% 置信区间计算和 P 值计算),使用了 SUDAAN 中的 REGRESS 程序来考虑聚类(即多次测量)。在计算 P 值时,对因变量进行了对数变换,以使分布正常化:咬合面和自由面的边缘拟合值受印模类型的影响。不同表面(咬合面和自由面)之间没有差异。DI 组获得的间隙为 164 ± 84 µm,CI 组为 209 ± 104 µm,两者之间存在统计学差异(p = .041)。DI 组的平均过伸值为 60 ± 59 µm,CI 组为 67 ± 73 µm,两者之间没有差异(p = .553):结论:与传统硅胶材料相比,数字印模获得的嵌体具有更高的临床边缘密合度,表现更好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Clinical comparison of marginal fit of ceramic inlays between digital and conventional impressions.

Purpose: The aim of this stuldy was to compare the clinical marginal fit of CAD-CAM inlays obtained from intraoral digital impression or addition silicone impression techniques.

Materials and methods: The study included 31 inlays for prosthodontics purposes of 31 patients: 15 based on intraoral digital impressions (DI group); and 16 based on a conventional impression technique (CI group). Inlays included occlusal and a non-occlusal surface. Inlays were milled in ceramic. The inlay-teeth interface was replicated by placing each inlay in its corresponding uncemented clinical preparation and taking interface impressions with silicone material from occlusal and free surfaces. Interface analysis was made using white light confocal microscopy (WLCM) (scanning area: 694 × 510 µm2) from the impression samples. The gap size and the inlay overextension were measured from the microscopy topographies. For analytical purposes (i.e., 95-%-confidence intervals calculations and P-value calculations), the procedure REGRESS in SUDAAN was used to account for clustering (i.e., multiple measurements). For p-value calculation, the log transformation of the dependent variables was used to normalize the distributions.

Results: Marginal fit values for occlusal and free surfaces were affected by the type of impression. There were no differences between surfaces (occlusal vs. free). Gap obtained for DI group was 164 ± 84 µm and that for CI group was 209 ± 104 µm, and there were statistical differences between them (p = .041). Mean overextension values were 60 ± 59 µm for DI group and 67 ± 73 µm for CI group, and there were no differences between then (p = .553).

Conclusion: Digital impression achieved inlays with higher clinical marginal fit and performed better than the conventional silicone materials.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Advanced Prosthodontics
Journal of Advanced Prosthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.70
自引率
3.80%
发文量
25
期刊介绍: This journal aims to convey scientific and clinical progress in the field of prosthodontics and its related areas to many dental communities concerned with esthetic and functional restorations, occlusion, implants, prostheses, and biomaterials related to prosthodontics. This journal publishes • Original research data of high scientific merit in the field of diagnosis, function, esthetics and stomatognathic physiology related to prosthodontic rehabilitation, physiology and mechanics of occlusion, mechanical and biologic aspects of prosthodontic materials including dental implants. • Review articles by experts on controversies and new developments in prosthodontics. • Case reports if they provide or document new fundamental knowledge.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信