Chang Jia, Bin Zou, Ying-Jie Sun, Bo Han, Yu-Gang Diao, Ya-Ting Li, Hui-Juan Cao
{"title":"阿芬太尼联合 0.075% 罗哌卡因用于硬膜外分娩镇痛的 90% 有效浓度:单中心、前瞻性、双盲顺序分配偏向硬币设计。","authors":"Chang Jia, Bin Zou, Ying-Jie Sun, Bo Han, Yu-Gang Diao, Ya-Ting Li, Hui-Juan Cao","doi":"10.1007/s00540-024-03322-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>More literature studies have reported that alfentanil is safe and effective for labor analgesia. However, there is no unified consensus on the optimal dosage of alfentanil used for epidural analgesia. This study explored the concentration at 90% of minimum effective concentration (EC90) of alfentanil combined with 0.075% ropivacaine in patients undergoing epidural labor analgesia to infer reasonable drug compatibility and provide guidance for clinical practice.</p><p><strong>Methods: </strong>In this prospective, single-center, double-blind study, a total of 45 singleton term primiparas with vaginal delivery who volunteered for epidural labor analgesia were recruited. The first maternal was administered with 3 μg/mL alfentanil combined with 0.075% ropivacaine with the infusion of 10 mL of the mixture every 50 min at a background dose of 3 mL/h. In the absence of PCEA, a total of 15 mL of the mixture is injected per hour. The subsequent alfentanil concentration was determined on the block efficacy of the previous case, using an up-down sequential allocation with a bias-coin design. 30 min after epidural labor analgesia, the block of patient failed with visual analog score (VAS) > 3, the alfentanil concentration was increased in a 0.5 μg/mL gradient for the next patient, while the block was successful with VAS ≤ 3, the alfentanil concentration was remained or decreased in a gradient according to a randomized response list for the next patient. EC90 and 95% confidence interval were calculated by linear interpolation and prediction model with R statistical software.</p><p><strong>Results: </strong>In this study, the estimated EC90 of alfentanil was 3.85 μg/mL (95% confidence interval, 3.64-4.28 μg/mL).</p><p><strong>Conclusion: </strong>When combined with ropivacaine 0.075%, the EC90 of alfentanil for epidural labor analgesia is 3.85 μg/mL in patients undergoing labor analgesia.</p>","PeriodicalId":14997,"journal":{"name":"Journal of Anesthesia","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11096240/pdf/","citationCount":"0","resultStr":"{\"title\":\"The 90% effective concentration of alfentanil combined with 0.075% ropivacaine for epidural labor analgesia: a single-center, prospective, double-blind sequential allocation biased-coin design.\",\"authors\":\"Chang Jia, Bin Zou, Ying-Jie Sun, Bo Han, Yu-Gang Diao, Ya-Ting Li, Hui-Juan Cao\",\"doi\":\"10.1007/s00540-024-03322-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>More literature studies have reported that alfentanil is safe and effective for labor analgesia. However, there is no unified consensus on the optimal dosage of alfentanil used for epidural analgesia. This study explored the concentration at 90% of minimum effective concentration (EC90) of alfentanil combined with 0.075% ropivacaine in patients undergoing epidural labor analgesia to infer reasonable drug compatibility and provide guidance for clinical practice.</p><p><strong>Methods: </strong>In this prospective, single-center, double-blind study, a total of 45 singleton term primiparas with vaginal delivery who volunteered for epidural labor analgesia were recruited. The first maternal was administered with 3 μg/mL alfentanil combined with 0.075% ropivacaine with the infusion of 10 mL of the mixture every 50 min at a background dose of 3 mL/h. In the absence of PCEA, a total of 15 mL of the mixture is injected per hour. The subsequent alfentanil concentration was determined on the block efficacy of the previous case, using an up-down sequential allocation with a bias-coin design. 30 min after epidural labor analgesia, the block of patient failed with visual analog score (VAS) > 3, the alfentanil concentration was increased in a 0.5 μg/mL gradient for the next patient, while the block was successful with VAS ≤ 3, the alfentanil concentration was remained or decreased in a gradient according to a randomized response list for the next patient. EC90 and 95% confidence interval were calculated by linear interpolation and prediction model with R statistical software.</p><p><strong>Results: </strong>In this study, the estimated EC90 of alfentanil was 3.85 μg/mL (95% confidence interval, 3.64-4.28 μg/mL).</p><p><strong>Conclusion: </strong>When combined with ropivacaine 0.075%, the EC90 of alfentanil for epidural labor analgesia is 3.85 μg/mL in patients undergoing labor analgesia.</p>\",\"PeriodicalId\":14997,\"journal\":{\"name\":\"Journal of Anesthesia\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11096240/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Anesthesia\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00540-024-03322-8\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Anesthesia","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00540-024-03322-8","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/5 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
The 90% effective concentration of alfentanil combined with 0.075% ropivacaine for epidural labor analgesia: a single-center, prospective, double-blind sequential allocation biased-coin design.
Purpose: More literature studies have reported that alfentanil is safe and effective for labor analgesia. However, there is no unified consensus on the optimal dosage of alfentanil used for epidural analgesia. This study explored the concentration at 90% of minimum effective concentration (EC90) of alfentanil combined with 0.075% ropivacaine in patients undergoing epidural labor analgesia to infer reasonable drug compatibility and provide guidance for clinical practice.
Methods: In this prospective, single-center, double-blind study, a total of 45 singleton term primiparas with vaginal delivery who volunteered for epidural labor analgesia were recruited. The first maternal was administered with 3 μg/mL alfentanil combined with 0.075% ropivacaine with the infusion of 10 mL of the mixture every 50 min at a background dose of 3 mL/h. In the absence of PCEA, a total of 15 mL of the mixture is injected per hour. The subsequent alfentanil concentration was determined on the block efficacy of the previous case, using an up-down sequential allocation with a bias-coin design. 30 min after epidural labor analgesia, the block of patient failed with visual analog score (VAS) > 3, the alfentanil concentration was increased in a 0.5 μg/mL gradient for the next patient, while the block was successful with VAS ≤ 3, the alfentanil concentration was remained or decreased in a gradient according to a randomized response list for the next patient. EC90 and 95% confidence interval were calculated by linear interpolation and prediction model with R statistical software.
Results: In this study, the estimated EC90 of alfentanil was 3.85 μg/mL (95% confidence interval, 3.64-4.28 μg/mL).
Conclusion: When combined with ropivacaine 0.075%, the EC90 of alfentanil for epidural labor analgesia is 3.85 μg/mL in patients undergoing labor analgesia.
期刊介绍:
The Journal of Anesthesia is the official journal of the Japanese Society of Anesthesiologists. This journal publishes original articles, review articles, special articles, clinical reports, short communications, letters to the editor, and book and multimedia reviews. The editors welcome the submission of manuscripts devoted to anesthesia and related topics from any country of the world. Membership in the Society is not a prerequisite.