通过感官评价和电子舌结合对感知咸度进行定量分析及其方法验证

IF 2.6 3区 农林科学 Q2 FOOD SCIENCE & TECHNOLOGY
Xue Xia, Ying Zhang, Jingyang Yu, Shiqing Song, Foxin Zhang, Khizar Hayat, Xiaoming Zhang, Chi-Tang Ho
{"title":"通过感官评价和电子舌结合对感知咸度进行定量分析及其方法验证","authors":"Xue Xia,&nbsp;Ying Zhang,&nbsp;Jingyang Yu,&nbsp;Shiqing Song,&nbsp;Foxin Zhang,&nbsp;Khizar Hayat,&nbsp;Xiaoming Zhang,&nbsp;Chi-Tang Ho","doi":"10.1007/s12161-024-02607-8","DOIUrl":null,"url":null,"abstract":"<div><p>A quantitative analysis of perceived saltiness was established by combining sensory perceived NaCl concentration with electronic tongue salty response. Saltiness index (SI) was defined as the ratio of perceived NaCl concentration to the actual NaCl concentration, and was proposed to evaluate the saltiness enchantment. Method validation of the saltiness sensor included assessments of linearity, repeatability, reproducibility, limit of detection, limit of quantitation, and recovery yield. A desirable linear relationship between the logarithm of perceived NaCl concentration and saltiness was observed at NaCl concentration ranging from 45 to 90 mM with a determination coefficient exceeding 0.99. A low relative standard deviation of less than 1% was achieved in the repeatability test. Through visual evaluation, the detection and quantitation limits of the saltiness sensor for NaCl solutions were determined to be 0.01 mM and 0.1 mM, respectively. A high recovery yield (97.6–108.3%) was obtained from the spike recovery test. Optional test solvents, including ultrapure water, distilled water, and pure water, were employed without interference. Upon adding 20–35 g/100 g potassium chloride, the salty response of the salt solution increased, while the linearity of NaCl solution remained unaffected. Saltiness enhancements of 37.20 ± 0.00% and 18.17 ± 0.18% were observed for the potassium-containing salt (30%, w/w) and oyster mushroom (<i>Pleurotus ostreatus</i>) peptides (0.3%, w/w), respectively. This evaluation method provided an effective and quantitative approach to advancing the development of salt reduction ingredients.</p></div>","PeriodicalId":561,"journal":{"name":"Food Analytical Methods","volume":"17 5","pages":"727 - 738"},"PeriodicalIF":2.6000,"publicationDate":"2024-03-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantitative Analysis of Perceived Saltiness through Combination of Sensory Evaluation and Electronic Tongue and its Method Validation\",\"authors\":\"Xue Xia,&nbsp;Ying Zhang,&nbsp;Jingyang Yu,&nbsp;Shiqing Song,&nbsp;Foxin Zhang,&nbsp;Khizar Hayat,&nbsp;Xiaoming Zhang,&nbsp;Chi-Tang Ho\",\"doi\":\"10.1007/s12161-024-02607-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A quantitative analysis of perceived saltiness was established by combining sensory perceived NaCl concentration with electronic tongue salty response. Saltiness index (SI) was defined as the ratio of perceived NaCl concentration to the actual NaCl concentration, and was proposed to evaluate the saltiness enchantment. Method validation of the saltiness sensor included assessments of linearity, repeatability, reproducibility, limit of detection, limit of quantitation, and recovery yield. A desirable linear relationship between the logarithm of perceived NaCl concentration and saltiness was observed at NaCl concentration ranging from 45 to 90 mM with a determination coefficient exceeding 0.99. A low relative standard deviation of less than 1% was achieved in the repeatability test. Through visual evaluation, the detection and quantitation limits of the saltiness sensor for NaCl solutions were determined to be 0.01 mM and 0.1 mM, respectively. A high recovery yield (97.6–108.3%) was obtained from the spike recovery test. Optional test solvents, including ultrapure water, distilled water, and pure water, were employed without interference. Upon adding 20–35 g/100 g potassium chloride, the salty response of the salt solution increased, while the linearity of NaCl solution remained unaffected. Saltiness enhancements of 37.20 ± 0.00% and 18.17 ± 0.18% were observed for the potassium-containing salt (30%, w/w) and oyster mushroom (<i>Pleurotus ostreatus</i>) peptides (0.3%, w/w), respectively. This evaluation method provided an effective and quantitative approach to advancing the development of salt reduction ingredients.</p></div>\",\"PeriodicalId\":561,\"journal\":{\"name\":\"Food Analytical Methods\",\"volume\":\"17 5\",\"pages\":\"727 - 738\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-03-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Food Analytical Methods\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s12161-024-02607-8\",\"RegionNum\":3,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"FOOD SCIENCE & TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Food Analytical Methods","FirstCategoryId":"97","ListUrlMain":"https://link.springer.com/article/10.1007/s12161-024-02607-8","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"FOOD SCIENCE & TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

通过将感官感知的 NaCl 浓度与电子舌咸味反应相结合,建立了感知咸味的定量分析。咸度指数 (SI) 被定义为感知的 NaCl 浓度与实际 NaCl 浓度之比,用于评估咸度的魅力。咸度传感器的方法验证包括线性、重复性、再现性、检测限、定量限和回收率的评估。在 NaCl 浓度为 45 至 90 毫摩尔时,可观察到 NaCl 感知浓度的对数与咸度之间存在理想的线性关系,测定系数超过 0.99。重复性测试的相对标准偏差小于 1%。通过目测评估,盐度传感器对 NaCl 溶液的检测限和定量限分别为 0.01 mM 和 0.1 mM。尖峰回收率测试的回收率很高(97.6-108.3%)。在使用超纯水、蒸馏水和纯净水等可选测试溶剂时均无干扰。加入 20-35 克/100 克氯化钾后,盐溶液的咸味反应增加,而氯化钠溶液的线性不受影响。含钾食盐(30%,重量比)和杏鲍菇肽(0.3%,重量比)的咸度分别增加了 37.20 ± 0.00% 和 18.17 ± 0.18%。这种评估方法为推动减盐成分的开发提供了一种有效的定量方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Quantitative Analysis of Perceived Saltiness through Combination of Sensory Evaluation and Electronic Tongue and its Method Validation

Quantitative Analysis of Perceived Saltiness through Combination of Sensory Evaluation and Electronic Tongue and its Method Validation

Quantitative Analysis of Perceived Saltiness through Combination of Sensory Evaluation and Electronic Tongue and its Method Validation

A quantitative analysis of perceived saltiness was established by combining sensory perceived NaCl concentration with electronic tongue salty response. Saltiness index (SI) was defined as the ratio of perceived NaCl concentration to the actual NaCl concentration, and was proposed to evaluate the saltiness enchantment. Method validation of the saltiness sensor included assessments of linearity, repeatability, reproducibility, limit of detection, limit of quantitation, and recovery yield. A desirable linear relationship between the logarithm of perceived NaCl concentration and saltiness was observed at NaCl concentration ranging from 45 to 90 mM with a determination coefficient exceeding 0.99. A low relative standard deviation of less than 1% was achieved in the repeatability test. Through visual evaluation, the detection and quantitation limits of the saltiness sensor for NaCl solutions were determined to be 0.01 mM and 0.1 mM, respectively. A high recovery yield (97.6–108.3%) was obtained from the spike recovery test. Optional test solvents, including ultrapure water, distilled water, and pure water, were employed without interference. Upon adding 20–35 g/100 g potassium chloride, the salty response of the salt solution increased, while the linearity of NaCl solution remained unaffected. Saltiness enhancements of 37.20 ± 0.00% and 18.17 ± 0.18% were observed for the potassium-containing salt (30%, w/w) and oyster mushroom (Pleurotus ostreatus) peptides (0.3%, w/w), respectively. This evaluation method provided an effective and quantitative approach to advancing the development of salt reduction ingredients.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Food Analytical Methods
Food Analytical Methods 农林科学-食品科技
CiteScore
6.00
自引率
3.40%
发文量
244
审稿时长
3.1 months
期刊介绍: Food Analytical Methods publishes original articles, review articles, and notes on novel and/or state-of-the-art analytical methods or issues to be solved, as well as significant improvements or interesting applications to existing methods. These include analytical technology and methodology for food microbial contaminants, food chemistry and toxicology, food quality, food authenticity and food traceability. The journal covers fundamental and specific aspects of the development, optimization, and practical implementation in routine laboratories, and validation of food analytical methods for the monitoring of food safety and quality.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信