{"title":"对立即植入并加载的传统和定制三维打印牙科植入体应力分布的三维有限元分析进行评估和比较。","authors":"Priya Saini, Vishakha Grover, Shaveta Sood, Ashish Jain, Parveen Kalra","doi":"10.4103/jisp.jisp_585_22","DOIUrl":null,"url":null,"abstract":"<p><strong>Aim: </strong>The aim of this study was to evaluate and compare the stress distribution patterns in immediately placed and loaded conventional and customized three-dimensional (3D) printed dental implants by 3D finite element analysis.</p><p><strong>Materials and methods: </strong>Twelve 3D finite element models [Group A-3 models; Group B-9 models] with 72 test conditions which were modeled and compared from customized 3D printed dental implants [Group A] and 3 commercially available implant systems [Group B] (Straumann, Ankylos, and Astratech) using \"SolidWorks\". All models were embedded in extraction socket models of the maxillary central incisor (CI) and Canine (C), Mandibular 1<sup>st</sup> Premolar. An occlusal loading by axial and nonaxial force of 100 N and 150 N at 30° and 45° was applied on the abutment using the \"ANSYS\" Suite. Customized 3D printed dental implant (Group A) for maxilla (Max.) CI, Max. C, and mandibular 1<sup>st</sup> premolar (PM) socket model was compared with three commercial available dental implant systems (Group B) for Max. CI, Max. C, and mandible (Mand.) 1<sup>st</sup> PM socket model to understand the stress distribution patterns.</p><p><strong>Results: </strong>With increasing oblique loads, von Mises stresses were reduced for the customized group as compared to conventional implants. Increased axial loads caused proportionate increase in the stresses for both groups, yet remained under the physiologic limits in all test conditions. Higher stresses were observed in cortical bone than in cancellous bone at bone-implant contact in general. Marked reduction in von Mises stress was observed at the boundary between compact and cancellous bone. Customized 3D printed implants performed better for oblique loads and comparable for axial load stress distribution in comparison to conventional implant systems in Max. CI and C, Mand. 1<sup>st</sup> PM.</p><p><strong>Conclusion: </strong>Thus, customized 3D printed implants appear a promising alternative for immediately placed immediately loaded protocols, with additional benefits in specific clinical situations.</p>","PeriodicalId":15890,"journal":{"name":"Journal of Indian Society of Periodontology","volume":"27 6","pages":"590-599"},"PeriodicalIF":0.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10906799/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation and comparison of three-dimensional finite element analysis of stress distribution in immediately placed and loaded conventional and customized three-dimensional printed dental implants.\",\"authors\":\"Priya Saini, Vishakha Grover, Shaveta Sood, Ashish Jain, Parveen Kalra\",\"doi\":\"10.4103/jisp.jisp_585_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aim: </strong>The aim of this study was to evaluate and compare the stress distribution patterns in immediately placed and loaded conventional and customized three-dimensional (3D) printed dental implants by 3D finite element analysis.</p><p><strong>Materials and methods: </strong>Twelve 3D finite element models [Group A-3 models; Group B-9 models] with 72 test conditions which were modeled and compared from customized 3D printed dental implants [Group A] and 3 commercially available implant systems [Group B] (Straumann, Ankylos, and Astratech) using \\\"SolidWorks\\\". All models were embedded in extraction socket models of the maxillary central incisor (CI) and Canine (C), Mandibular 1<sup>st</sup> Premolar. An occlusal loading by axial and nonaxial force of 100 N and 150 N at 30° and 45° was applied on the abutment using the \\\"ANSYS\\\" Suite. Customized 3D printed dental implant (Group A) for maxilla (Max.) CI, Max. C, and mandibular 1<sup>st</sup> premolar (PM) socket model was compared with three commercial available dental implant systems (Group B) for Max. CI, Max. C, and mandible (Mand.) 1<sup>st</sup> PM socket model to understand the stress distribution patterns.</p><p><strong>Results: </strong>With increasing oblique loads, von Mises stresses were reduced for the customized group as compared to conventional implants. Increased axial loads caused proportionate increase in the stresses for both groups, yet remained under the physiologic limits in all test conditions. Higher stresses were observed in cortical bone than in cancellous bone at bone-implant contact in general. Marked reduction in von Mises stress was observed at the boundary between compact and cancellous bone. Customized 3D printed implants performed better for oblique loads and comparable for axial load stress distribution in comparison to conventional implant systems in Max. CI and C, Mand. 1<sup>st</sup> PM.</p><p><strong>Conclusion: </strong>Thus, customized 3D printed implants appear a promising alternative for immediately placed immediately loaded protocols, with additional benefits in specific clinical situations.</p>\",\"PeriodicalId\":15890,\"journal\":{\"name\":\"Journal of Indian Society of Periodontology\",\"volume\":\"27 6\",\"pages\":\"590-599\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10906799/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Indian Society of Periodontology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jisp.jisp_585_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/24 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian Society of Periodontology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jisp.jisp_585_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/24 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究旨在通过三维有限元分析,评估和比较即刻植入和加载的传统牙科种植体与定制的三维(3D)打印牙科种植体的应力分布模式:使用 "SolidWorks "对定制的三维打印牙科种植体[A 组]和三种市售种植体系统[B 组](Straumann、Ankylos 和 Astratech)[A 组]的 12 个三维有限元模型[A 组-3 个模型;B 组-9 个模型]的 72 种测试条件进行建模和比较。所有模型均嵌入上颌中切牙(CI)和犬齿(C)、下颌第一前磨牙的拔牙窝模型中。使用 "ANSYS "套件对基台施加轴向和非轴向载荷,载荷分别为 100 牛顿和 150 牛顿,角度分别为 30°和 45°。定制的 3D 打印种植体(A 组)用于上颌(Max.)C和下颌第一前磨牙(PM)牙槽模型的定制3D打印种植体(A组)与三种商业牙科种植体系统(B组)(Max.CI、Max.C和下颌(Mand. )第一前磨牙(PM)牙槽模型与三种市售牙科种植系统(B组)的最大CI、最大C和下颌(Mand:结果:与传统种植体相比,随着斜向载荷的增加,定制组的 von Mises 应力有所降低。轴向载荷的增加导致两组的应力成比例增加,但在所有测试条件下均保持在生理极限范围内。在骨与种植体接触处,皮质骨的应力普遍高于松质骨。在密质骨和松质骨的交界处,Von Mises 应力明显降低。在 Max.CI和C,Mand.结论:因此,定制的三维打印种植体似乎是即刻植入即刻加载方案的一种很有前景的替代方案,在特定的临床情况下具有额外的优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation and comparison of three-dimensional finite element analysis of stress distribution in immediately placed and loaded conventional and customized three-dimensional printed dental implants.

Aim: The aim of this study was to evaluate and compare the stress distribution patterns in immediately placed and loaded conventional and customized three-dimensional (3D) printed dental implants by 3D finite element analysis.

Materials and methods: Twelve 3D finite element models [Group A-3 models; Group B-9 models] with 72 test conditions which were modeled and compared from customized 3D printed dental implants [Group A] and 3 commercially available implant systems [Group B] (Straumann, Ankylos, and Astratech) using "SolidWorks". All models were embedded in extraction socket models of the maxillary central incisor (CI) and Canine (C), Mandibular 1st Premolar. An occlusal loading by axial and nonaxial force of 100 N and 150 N at 30° and 45° was applied on the abutment using the "ANSYS" Suite. Customized 3D printed dental implant (Group A) for maxilla (Max.) CI, Max. C, and mandibular 1st premolar (PM) socket model was compared with three commercial available dental implant systems (Group B) for Max. CI, Max. C, and mandible (Mand.) 1st PM socket model to understand the stress distribution patterns.

Results: With increasing oblique loads, von Mises stresses were reduced for the customized group as compared to conventional implants. Increased axial loads caused proportionate increase in the stresses for both groups, yet remained under the physiologic limits in all test conditions. Higher stresses were observed in cortical bone than in cancellous bone at bone-implant contact in general. Marked reduction in von Mises stress was observed at the boundary between compact and cancellous bone. Customized 3D printed implants performed better for oblique loads and comparable for axial load stress distribution in comparison to conventional implant systems in Max. CI and C, Mand. 1st PM.

Conclusion: Thus, customized 3D printed implants appear a promising alternative for immediately placed immediately loaded protocols, with additional benefits in specific clinical situations.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
87
审稿时长
44 weeks
期刊介绍: The Journal of Indian Society of Periodontology publishes original scientific articles to support practice , education and research in the dental specialty of periodontology and oral implantology. Journal of Indian Society of Periodontology (JISP), is the official publication of the Society and is managed and brought out by the Editor of the society. The journal is published Bimonthly with special issues being brought out for specific occasions. The ISP had a bulletin as its publication for a large number of years and was enhanced as a Journal a few years ago
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信