用于智能贴片汗液测量的气溶胶喷印电位 pH 传感器

IF 5.4 Q1 CHEMISTRY, ANALYTICAL
Jan Dominiczak , Jakub Krzemiński , Justyna Wojcieszek , Dominik Baraniecki , Filip Budny , Izabela Wojciechowska , Piotr Walter , Andrzej Pepłowski , Łukasz Górski , Małgorzata Jakubowska
{"title":"用于智能贴片汗液测量的气溶胶喷印电位 pH 传感器","authors":"Jan Dominiczak ,&nbsp;Jakub Krzemiński ,&nbsp;Justyna Wojcieszek ,&nbsp;Dominik Baraniecki ,&nbsp;Filip Budny ,&nbsp;Izabela Wojciechowska ,&nbsp;Piotr Walter ,&nbsp;Andrzej Pepłowski ,&nbsp;Łukasz Górski ,&nbsp;Małgorzata Jakubowska","doi":"10.1016/j.sbsr.2024.100636","DOIUrl":null,"url":null,"abstract":"<div><p>Manufacturing technology of ion-selective electrodes (ISEs) for pH measurements is presented. Plasticized polyurethane membranes with tridodecylamine as a pH-selective ionophore were used as receptor layer, whereas electrodes printed with graphene nanoplatelets paste served as transducers. For preliminary experiments, sensors with screen-printed transducers and pH-selective membranes deposited manually or by direct-ink writing, were employed. However, the use of aerosol-jet printing (AJP) technique for the production of transducer as well as deposition of pH-selective polymeric membrane allowed substantial miniaturization of the sensors, leading to low-cost, automated fabrication of millimeter-scale ISEs. The pH sensors were printed on thermoplastic polyurethane (TPU) or polyethylene terephthalate (PET) substrate, the issues of compatibility of membrane and substrate materials were addressed. The average membrane thickness for the ISEs was 225.2 ± 8.0 μm with an additional 20 μm average thickness of other underlying printed layers. The planar dimensions of ISEs were 300 μm (width) by 2 mm, presenting an opportunity for even further miniaturization. Sensors fully printed with the AJP technique yielded a potentiometric response of −53.48 ± 4.26 mV/pH (<em>N</em> = 69) for PET substrate and − 46.71 ± 10.23 mV/pH (<em>N</em> = 66) for TPU substrate. Presented results are important for developing a fully operational electronic tattoo suitable for large-scale manufacturing.</p></div>","PeriodicalId":424,"journal":{"name":"Sensing and Bio-Sensing Research","volume":"43 ","pages":"Article 100636"},"PeriodicalIF":5.4000,"publicationDate":"2024-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2214180424000187/pdfft?md5=bed6e922c30218d8d430821ef1090a45&pid=1-s2.0-S2214180424000187-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Aerosol-jet-printed potentiometric pH sensor for sweat measurements in smart patches\",\"authors\":\"Jan Dominiczak ,&nbsp;Jakub Krzemiński ,&nbsp;Justyna Wojcieszek ,&nbsp;Dominik Baraniecki ,&nbsp;Filip Budny ,&nbsp;Izabela Wojciechowska ,&nbsp;Piotr Walter ,&nbsp;Andrzej Pepłowski ,&nbsp;Łukasz Górski ,&nbsp;Małgorzata Jakubowska\",\"doi\":\"10.1016/j.sbsr.2024.100636\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Manufacturing technology of ion-selective electrodes (ISEs) for pH measurements is presented. Plasticized polyurethane membranes with tridodecylamine as a pH-selective ionophore were used as receptor layer, whereas electrodes printed with graphene nanoplatelets paste served as transducers. For preliminary experiments, sensors with screen-printed transducers and pH-selective membranes deposited manually or by direct-ink writing, were employed. However, the use of aerosol-jet printing (AJP) technique for the production of transducer as well as deposition of pH-selective polymeric membrane allowed substantial miniaturization of the sensors, leading to low-cost, automated fabrication of millimeter-scale ISEs. The pH sensors were printed on thermoplastic polyurethane (TPU) or polyethylene terephthalate (PET) substrate, the issues of compatibility of membrane and substrate materials were addressed. The average membrane thickness for the ISEs was 225.2 ± 8.0 μm with an additional 20 μm average thickness of other underlying printed layers. The planar dimensions of ISEs were 300 μm (width) by 2 mm, presenting an opportunity for even further miniaturization. Sensors fully printed with the AJP technique yielded a potentiometric response of −53.48 ± 4.26 mV/pH (<em>N</em> = 69) for PET substrate and − 46.71 ± 10.23 mV/pH (<em>N</em> = 66) for TPU substrate. Presented results are important for developing a fully operational electronic tattoo suitable for large-scale manufacturing.</p></div>\",\"PeriodicalId\":424,\"journal\":{\"name\":\"Sensing and Bio-Sensing Research\",\"volume\":\"43 \",\"pages\":\"Article 100636\"},\"PeriodicalIF\":5.4000,\"publicationDate\":\"2024-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2214180424000187/pdfft?md5=bed6e922c30218d8d430821ef1090a45&pid=1-s2.0-S2214180424000187-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensing and Bio-Sensing Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2214180424000187\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensing and Bio-Sensing Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2214180424000187","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了用于 pH 值测量的离子选择电极(ISE)的制造技术。使用含有十三烷基胺作为 pH 选择性离子载体的塑化聚氨酯膜作为受体层,而印有石墨烯纳米浆料的电极则作为换能器。在初步实验中,传感器采用了丝网印刷换能器和 pH 选择膜,这些换能器和膜都是手工或直接涂墨沉积的。然而,使用气溶胶喷射打印(AJP)技术生产换能器和沉积 pH 选择性聚合膜后,传感器得以大幅微型化,从而实现了毫米级 ISE 的低成本自动化制造。pH 传感器印制在热塑性聚氨酯(TPU)或聚对苯二甲酸乙二醇酯(PET)基底上,解决了膜和基底材料的兼容性问题。ISE 的平均膜厚为 225.2 ± 8.0 μm,其他底层印刷层的平均厚度为 20 μm。ISE 的平面尺寸为 300 微米(宽)x 2 毫米,这为进一步微型化提供了机会。采用 AJP 技术完全印刷的传感器对 PET 基底的电位响应为 -53.48 ± 4.26 mV/pH ( = 69),对 TPU 基底的响应为 -46.71 ± 10.23 mV/pH ( = 66)。这些结果对于开发适合大规模制造的全功能电子纹身非常重要。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Aerosol-jet-printed potentiometric pH sensor for sweat measurements in smart patches

Manufacturing technology of ion-selective electrodes (ISEs) for pH measurements is presented. Plasticized polyurethane membranes with tridodecylamine as a pH-selective ionophore were used as receptor layer, whereas electrodes printed with graphene nanoplatelets paste served as transducers. For preliminary experiments, sensors with screen-printed transducers and pH-selective membranes deposited manually or by direct-ink writing, were employed. However, the use of aerosol-jet printing (AJP) technique for the production of transducer as well as deposition of pH-selective polymeric membrane allowed substantial miniaturization of the sensors, leading to low-cost, automated fabrication of millimeter-scale ISEs. The pH sensors were printed on thermoplastic polyurethane (TPU) or polyethylene terephthalate (PET) substrate, the issues of compatibility of membrane and substrate materials were addressed. The average membrane thickness for the ISEs was 225.2 ± 8.0 μm with an additional 20 μm average thickness of other underlying printed layers. The planar dimensions of ISEs were 300 μm (width) by 2 mm, presenting an opportunity for even further miniaturization. Sensors fully printed with the AJP technique yielded a potentiometric response of −53.48 ± 4.26 mV/pH (N = 69) for PET substrate and − 46.71 ± 10.23 mV/pH (N = 66) for TPU substrate. Presented results are important for developing a fully operational electronic tattoo suitable for large-scale manufacturing.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sensing and Bio-Sensing Research
Sensing and Bio-Sensing Research Engineering-Electrical and Electronic Engineering
CiteScore
10.70
自引率
3.80%
发文量
68
审稿时长
87 days
期刊介绍: Sensing and Bio-Sensing Research is an open access journal dedicated to the research, design, development, and application of bio-sensing and sensing technologies. The editors will accept research papers, reviews, field trials, and validation studies that are of significant relevance. These submissions should describe new concepts, enhance understanding of the field, or offer insights into the practical application, manufacturing, and commercialization of bio-sensing and sensing technologies. The journal covers a wide range of topics, including sensing principles and mechanisms, new materials development for transducers and recognition components, fabrication technology, and various types of sensors such as optical, electrochemical, mass-sensitive, gas, biosensors, and more. It also includes environmental, process control, and biomedical applications, signal processing, chemometrics, optoelectronic, mechanical, thermal, and magnetic sensors, as well as interface electronics. Additionally, it covers sensor systems and applications, µTAS (Micro Total Analysis Systems), development of solid-state devices for transducing physical signals, and analytical devices incorporating biological materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信