Fumiki Takahashi, Yuki Shimosaka, Shuki Mori, Mayu Kaneko, Yuta Harayama, Kanya Kobayashi, Taku Shoji, Yasuo Seto, Hirosuke Tatsumi, Jiye Jin
{"title":"开发电位调节电化学发光测量系统,用于选择性和灵敏度地测定受管制药物可待因","authors":"Fumiki Takahashi, Yuki Shimosaka, Shuki Mori, Mayu Kaneko, Yuta Harayama, Kanya Kobayashi, Taku Shoji, Yasuo Seto, Hirosuke Tatsumi, Jiye Jin","doi":"10.1248/cpb.c23-00585","DOIUrl":null,"url":null,"abstract":"</p><p>Codeine is a common analgesic drug that is a pro-drug of morphine. It also has a high risk of abuse as a recreational drug because of its extensive distribution as an OTC drug. Therefore, sensitive and selective screening methods for codeine are crucial in forensic analytical chemistry. To date, a commercial analytical kit has not been developed for dedicated codeine determination, and there is a need for an analytical method to quantify codeine in the field. In the present work, potential modulation was combined with electrochemiluminescence (ECL) for sensitive determination of codeine. The potential modulated technique involved applying a signal to electrodes by superimposing an AC potential on the DC potential. When tris(2,2′-bipyridine)ruthenium(II) ([Ru(bpy)<sub>3</sub>]<sup>2+</sup>) was used as an ECL emitter, ECL activity was confirmed for codeine. A detailed investigation of the electrochemical reaction mechanism suggested a characteristic ECL reaction mechanism involving electrochemical oxidation of the opioid framework. Besides the usual ECL reaction derived from the amine framework, selective detection of codeine was possible under the measurement conditions, with clear luminescence observed in an acidic solution. The sensitivity of codeine detection by potential modulated-ECL was one order of magnitude higher than that obtained with the conventional potential sweep method. The proposed method was applied to codeine determination in actual prescription medications and OTC drug samples. Codeine was selectively determined from other compounds in medications and showed good linearity with a low detection limit (150 ng mL<sup>−1</sup>).</p>\n<p></p>\n<img alt=\"\" src=\"https://www.jstage.jst.go.jp/pub/cpb/72/3/72_c23-00585/figure/72_c23-00585.png\"/>\n<span style=\"padding-left:5px;\">Fullsize Image</span>","PeriodicalId":9773,"journal":{"name":"Chemical & pharmaceutical bulletin","volume":"54 1","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a Potential-Modulated Electrochemiluminescence Measurement System for Selective and Sensitive Determination of the Controlled Drug Codeine\",\"authors\":\"Fumiki Takahashi, Yuki Shimosaka, Shuki Mori, Mayu Kaneko, Yuta Harayama, Kanya Kobayashi, Taku Shoji, Yasuo Seto, Hirosuke Tatsumi, Jiye Jin\",\"doi\":\"10.1248/cpb.c23-00585\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"</p><p>Codeine is a common analgesic drug that is a pro-drug of morphine. It also has a high risk of abuse as a recreational drug because of its extensive distribution as an OTC drug. Therefore, sensitive and selective screening methods for codeine are crucial in forensic analytical chemistry. To date, a commercial analytical kit has not been developed for dedicated codeine determination, and there is a need for an analytical method to quantify codeine in the field. In the present work, potential modulation was combined with electrochemiluminescence (ECL) for sensitive determination of codeine. The potential modulated technique involved applying a signal to electrodes by superimposing an AC potential on the DC potential. When tris(2,2′-bipyridine)ruthenium(II) ([Ru(bpy)<sub>3</sub>]<sup>2+</sup>) was used as an ECL emitter, ECL activity was confirmed for codeine. A detailed investigation of the electrochemical reaction mechanism suggested a characteristic ECL reaction mechanism involving electrochemical oxidation of the opioid framework. Besides the usual ECL reaction derived from the amine framework, selective detection of codeine was possible under the measurement conditions, with clear luminescence observed in an acidic solution. The sensitivity of codeine detection by potential modulated-ECL was one order of magnitude higher than that obtained with the conventional potential sweep method. The proposed method was applied to codeine determination in actual prescription medications and OTC drug samples. Codeine was selectively determined from other compounds in medications and showed good linearity with a low detection limit (150 ng mL<sup>−1</sup>).</p>\\n<p></p>\\n<img alt=\\\"\\\" src=\\\"https://www.jstage.jst.go.jp/pub/cpb/72/3/72_c23-00585/figure/72_c23-00585.png\\\"/>\\n<span style=\\\"padding-left:5px;\\\">Fullsize Image</span>\",\"PeriodicalId\":9773,\"journal\":{\"name\":\"Chemical & pharmaceutical bulletin\",\"volume\":\"54 1\",\"pages\":\"\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chemical & pharmaceutical bulletin\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1248/cpb.c23-00585\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, MEDICINAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical & pharmaceutical bulletin","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1248/cpb.c23-00585","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, MEDICINAL","Score":null,"Total":0}
Development of a Potential-Modulated Electrochemiluminescence Measurement System for Selective and Sensitive Determination of the Controlled Drug Codeine
Codeine is a common analgesic drug that is a pro-drug of morphine. It also has a high risk of abuse as a recreational drug because of its extensive distribution as an OTC drug. Therefore, sensitive and selective screening methods for codeine are crucial in forensic analytical chemistry. To date, a commercial analytical kit has not been developed for dedicated codeine determination, and there is a need for an analytical method to quantify codeine in the field. In the present work, potential modulation was combined with electrochemiluminescence (ECL) for sensitive determination of codeine. The potential modulated technique involved applying a signal to electrodes by superimposing an AC potential on the DC potential. When tris(2,2′-bipyridine)ruthenium(II) ([Ru(bpy)3]2+) was used as an ECL emitter, ECL activity was confirmed for codeine. A detailed investigation of the electrochemical reaction mechanism suggested a characteristic ECL reaction mechanism involving electrochemical oxidation of the opioid framework. Besides the usual ECL reaction derived from the amine framework, selective detection of codeine was possible under the measurement conditions, with clear luminescence observed in an acidic solution. The sensitivity of codeine detection by potential modulated-ECL was one order of magnitude higher than that obtained with the conventional potential sweep method. The proposed method was applied to codeine determination in actual prescription medications and OTC drug samples. Codeine was selectively determined from other compounds in medications and showed good linearity with a low detection limit (150 ng mL−1).
期刊介绍:
The CPB covers various chemical topics in the pharmaceutical and health sciences fields dealing with biologically active compounds, natural products, and medicines, while BPB deals with a wide range of biological topics in the pharmaceutical and health sciences fields including scientific research from basic to clinical studies. For details of their respective scopes, please refer to the submission topic categories below.
Topics: Organic chemistry
In silico science
Inorganic chemistry
Pharmacognosy
Health statistics
Forensic science
Biochemistry
Pharmacology
Pharmaceutical care and science
Medicinal chemistry
Analytical chemistry
Physical pharmacy
Natural product chemistry
Toxicology
Environmental science
Molecular and cellular biology
Biopharmacy and pharmacokinetics
Pharmaceutical education
Chemical biology
Physical chemistry
Pharmaceutical engineering
Epidemiology
Hygiene
Regulatory science
Immunology and microbiology
Clinical pharmacy
Miscellaneous.