{"title":"纳米压痕校准程序的改进:压头钝度指示器","authors":"D. Chicot, A. Montagne, A. Mejias, F. Roudet, T. Coorevits","doi":"10.1007/s11340-024-01048-y","DOIUrl":null,"url":null,"abstract":"<h3 data-test=\"abstract-sub-heading\">Background</h3><p>Nanoindentation experiments require the calibration of the tip area function, which involves up to 9 fitting coefficients following classical method. These coefficients are determined from indentation tests on a reference material. However, their values may vary from one test batch to another. Consequently, these coefficients cannot describe the amplitude of the indenter tip defect.</p><h3 data-test=\"abstract-sub-heading\">Objective</h3><p>The main objective of this study is to propose a contact area function that uses only one fitting coefficient to represent the indenter tip defect. This coefficient corresponds to the distance between the blunt and ideal indenter tip.</p><h3 data-test=\"abstract-sub-heading\">Methodology</h3><p>To demonstrate the efficiency of the proposed contact area function, we reanalyzed nearly 40 calibration procedures, while keeping the same experimental protocol, performed between 2014 and today. A novel two-step calibration methodology is advanced. We compared the results of the proposed method to those obtained with the classic methodology.</p><h3 data-test=\"abstract-sub-heading\">Results</h3><p>This two-step methodology was applied to a fused silica calibration sample. The values of the Young's modulus and instrumented hardness are equals to 71 and 10 GPa, respectively. The length of the indenter tip defect increases gradually from 5 to 30 nm accordingly to the frequency of use of the indenter. The values of the mechanical properties calculated by this methodology are in good agreement with those obtained using the classical contact area function.</p><h3 data-test=\"abstract-sub-heading\">Conclusion</h3><p>The methodology presented in this paper demonstrates its ability to accurately calibrate the tip area function. This new calibration procedure considers both the Young’s modulus and the tip defect parameter as free parameters. Furthermore, the calibration parameters have a clear physical meaning and their values remain stables from one batch to another.</p>","PeriodicalId":552,"journal":{"name":"Experimental Mechanics","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Improvement in Calibration Procedure in Nanoindentation: An Indenter Bluntness Indicator\",\"authors\":\"D. Chicot, A. Montagne, A. Mejias, F. Roudet, T. Coorevits\",\"doi\":\"10.1007/s11340-024-01048-y\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3 data-test=\\\"abstract-sub-heading\\\">Background</h3><p>Nanoindentation experiments require the calibration of the tip area function, which involves up to 9 fitting coefficients following classical method. These coefficients are determined from indentation tests on a reference material. However, their values may vary from one test batch to another. Consequently, these coefficients cannot describe the amplitude of the indenter tip defect.</p><h3 data-test=\\\"abstract-sub-heading\\\">Objective</h3><p>The main objective of this study is to propose a contact area function that uses only one fitting coefficient to represent the indenter tip defect. This coefficient corresponds to the distance between the blunt and ideal indenter tip.</p><h3 data-test=\\\"abstract-sub-heading\\\">Methodology</h3><p>To demonstrate the efficiency of the proposed contact area function, we reanalyzed nearly 40 calibration procedures, while keeping the same experimental protocol, performed between 2014 and today. A novel two-step calibration methodology is advanced. We compared the results of the proposed method to those obtained with the classic methodology.</p><h3 data-test=\\\"abstract-sub-heading\\\">Results</h3><p>This two-step methodology was applied to a fused silica calibration sample. The values of the Young's modulus and instrumented hardness are equals to 71 and 10 GPa, respectively. The length of the indenter tip defect increases gradually from 5 to 30 nm accordingly to the frequency of use of the indenter. The values of the mechanical properties calculated by this methodology are in good agreement with those obtained using the classical contact area function.</p><h3 data-test=\\\"abstract-sub-heading\\\">Conclusion</h3><p>The methodology presented in this paper demonstrates its ability to accurately calibrate the tip area function. This new calibration procedure considers both the Young’s modulus and the tip defect parameter as free parameters. Furthermore, the calibration parameters have a clear physical meaning and their values remain stables from one batch to another.</p>\",\"PeriodicalId\":552,\"journal\":{\"name\":\"Experimental Mechanics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Experimental Mechanics\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s11340-024-01048-y\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, CHARACTERIZATION & TESTING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Experimental Mechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s11340-024-01048-y","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, CHARACTERIZATION & TESTING","Score":null,"Total":0}
引用次数: 0

摘要

背景纳米压痕实验需要校准针尖面积函数,按照经典方法,这涉及多达 9 个拟合系数。这些系数是根据参考材料的压痕测试确定的。然而,它们的值可能会因测试批次的不同而不同。本研究的主要目的是提出一种接触面积函数,该函数只使用一个拟合系数来表示压头尖端缺陷。为了证明所提出的接触面积函数的效率,我们重新分析了 2014 年至今进行的近 40 次校准过程,同时保持相同的实验方案。我们提出了一种新颖的两步校准方法。我们将所提方法的结果与经典方法的结果进行了比较。杨氏模量和仪器硬度值分别等于 71 和 10 GPa。随着压头使用频率的增加,压头尖端缺陷的长度从 5 纳米逐渐增加到 30 纳米。本文提出的方法证明了其精确校准顶端面积函数的能力。这种新的校准程序将杨氏模量和针尖缺陷参数都视为自由参数。此外,校准参数具有明确的物理意义,其值在不同批次之间保持稳定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Improvement in Calibration Procedure in Nanoindentation: An Indenter Bluntness Indicator

Improvement in Calibration Procedure in Nanoindentation: An Indenter Bluntness Indicator

Background

Nanoindentation experiments require the calibration of the tip area function, which involves up to 9 fitting coefficients following classical method. These coefficients are determined from indentation tests on a reference material. However, their values may vary from one test batch to another. Consequently, these coefficients cannot describe the amplitude of the indenter tip defect.

Objective

The main objective of this study is to propose a contact area function that uses only one fitting coefficient to represent the indenter tip defect. This coefficient corresponds to the distance between the blunt and ideal indenter tip.

Methodology

To demonstrate the efficiency of the proposed contact area function, we reanalyzed nearly 40 calibration procedures, while keeping the same experimental protocol, performed between 2014 and today. A novel two-step calibration methodology is advanced. We compared the results of the proposed method to those obtained with the classic methodology.

Results

This two-step methodology was applied to a fused silica calibration sample. The values of the Young's modulus and instrumented hardness are equals to 71 and 10 GPa, respectively. The length of the indenter tip defect increases gradually from 5 to 30 nm accordingly to the frequency of use of the indenter. The values of the mechanical properties calculated by this methodology are in good agreement with those obtained using the classical contact area function.

Conclusion

The methodology presented in this paper demonstrates its ability to accurately calibrate the tip area function. This new calibration procedure considers both the Young’s modulus and the tip defect parameter as free parameters. Furthermore, the calibration parameters have a clear physical meaning and their values remain stables from one batch to another.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Experimental Mechanics
Experimental Mechanics 物理-材料科学:表征与测试
CiteScore
4.40
自引率
16.70%
发文量
111
审稿时长
3 months
期刊介绍: Experimental Mechanics is the official journal of the Society for Experimental Mechanics that publishes papers in all areas of experimentation including its theoretical and computational analysis. The journal covers research in design and implementation of novel or improved experiments to characterize materials, structures and systems. Articles extending the frontiers of experimental mechanics at large and small scales are particularly welcome. Coverage extends from research in solid and fluids mechanics to fields at the intersection of disciplines including physics, chemistry and biology. Development of new devices and technologies for metrology applications in a wide range of industrial sectors (e.g., manufacturing, high-performance materials, aerospace, information technology, medicine, energy and environmental technologies) is also covered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信