Luis Leal-Vega, David P Piñero, Ainhoa Molina-Martín, Carlos J Hernández-Rodríguez, Rubén Cuadrado-Asensio, Adrián Martín-Gutiérrez, Juan Francisco Arenillas Lara, María Begoña Coco Martín
{"title":"评估用于改善视觉功能的新型虚拟现实系统的安全性和接受度的试点研究。","authors":"Luis Leal-Vega, David P Piñero, Ainhoa Molina-Martín, Carlos J Hernández-Rodríguez, Rubén Cuadrado-Asensio, Adrián Martín-Gutiérrez, Juan Francisco Arenillas Lara, María Begoña Coco Martín","doi":"10.1080/08820538.2024.2324074","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To assess the feasibility of the clinical use of a novel Virtual Reality (VR) training software designed to be used for active vision therapy in amblyopic patients by determining its preliminary safety and acceptance on the visual function of healthy adults.</p><p><strong>Methods: </strong>Pilot study enrolling 10 individuals (3 men, 7 women, mean age: 31.8 ± 6.5 years) with a best-corrected visual acuity (BCVA) of ≥ .90 (decimal) in both eyes were evaluated before and after 20 minutes of exposure to the NEIVATECH VR system using the HTC Vive Pro Eye head mounted display. Visual function assessment included near (40 cm) and distance (6 m) cover test (CT), stereopsis, binocular accommodative facility (BAF), near point of convergence (NPC), near point of accommodation (NPA), accommodative-convergence over accommodation (AC/A) ratio and positive and negative fusional vergences. Safety was assessed using the VR Sickness Questionnaire (VRSQ) and acceptance using the Technology Acceptance Model ;(TAM). Changes in all these variables after VR exposure were analyzed.</p><p><strong>Results: </strong>Short-term exposure to the NEIVATECH VR system only induced statistically significant changes in distance phoria (<i>p</i> = .016), but these changes were not clinically relevant. No significant changes were observed in VRSQ oculo-motricity and disorientation scores after exposure (<i>p</i> = .197 and .317, respectively). TAM scores showed a good acceptance of the system in terms of perceived enjoyment and perceived ease of use, although some concerns were raised in relation to the intention-to-use domain.</p><p><strong>Conclusion: </strong>Exposure to the NEIVATECH VR system does not seem to adversely affect the visual function in healthy adults and its safety and acceptance profile seems to be adequate for supporting its potential use in other populations, such as amblyopic patients.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Pilot Study Assessing the Safety and Acceptance of a Novel Virtual Reality System to Improve Visual Function.\",\"authors\":\"Luis Leal-Vega, David P Piñero, Ainhoa Molina-Martín, Carlos J Hernández-Rodríguez, Rubén Cuadrado-Asensio, Adrián Martín-Gutiérrez, Juan Francisco Arenillas Lara, María Begoña Coco Martín\",\"doi\":\"10.1080/08820538.2024.2324074\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To assess the feasibility of the clinical use of a novel Virtual Reality (VR) training software designed to be used for active vision therapy in amblyopic patients by determining its preliminary safety and acceptance on the visual function of healthy adults.</p><p><strong>Methods: </strong>Pilot study enrolling 10 individuals (3 men, 7 women, mean age: 31.8 ± 6.5 years) with a best-corrected visual acuity (BCVA) of ≥ .90 (decimal) in both eyes were evaluated before and after 20 minutes of exposure to the NEIVATECH VR system using the HTC Vive Pro Eye head mounted display. Visual function assessment included near (40 cm) and distance (6 m) cover test (CT), stereopsis, binocular accommodative facility (BAF), near point of convergence (NPC), near point of accommodation (NPA), accommodative-convergence over accommodation (AC/A) ratio and positive and negative fusional vergences. Safety was assessed using the VR Sickness Questionnaire (VRSQ) and acceptance using the Technology Acceptance Model ;(TAM). Changes in all these variables after VR exposure were analyzed.</p><p><strong>Results: </strong>Short-term exposure to the NEIVATECH VR system only induced statistically significant changes in distance phoria (<i>p</i> = .016), but these changes were not clinically relevant. No significant changes were observed in VRSQ oculo-motricity and disorientation scores after exposure (<i>p</i> = .197 and .317, respectively). TAM scores showed a good acceptance of the system in terms of perceived enjoyment and perceived ease of use, although some concerns were raised in relation to the intention-to-use domain.</p><p><strong>Conclusion: </strong>Exposure to the NEIVATECH VR system does not seem to adversely affect the visual function in healthy adults and its safety and acceptance profile seems to be adequate for supporting its potential use in other populations, such as amblyopic patients.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/08820538.2024.2324074\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/3/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/08820538.2024.2324074","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/3/1 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
Pilot Study Assessing the Safety and Acceptance of a Novel Virtual Reality System to Improve Visual Function.
Purpose: To assess the feasibility of the clinical use of a novel Virtual Reality (VR) training software designed to be used for active vision therapy in amblyopic patients by determining its preliminary safety and acceptance on the visual function of healthy adults.
Methods: Pilot study enrolling 10 individuals (3 men, 7 women, mean age: 31.8 ± 6.5 years) with a best-corrected visual acuity (BCVA) of ≥ .90 (decimal) in both eyes were evaluated before and after 20 minutes of exposure to the NEIVATECH VR system using the HTC Vive Pro Eye head mounted display. Visual function assessment included near (40 cm) and distance (6 m) cover test (CT), stereopsis, binocular accommodative facility (BAF), near point of convergence (NPC), near point of accommodation (NPA), accommodative-convergence over accommodation (AC/A) ratio and positive and negative fusional vergences. Safety was assessed using the VR Sickness Questionnaire (VRSQ) and acceptance using the Technology Acceptance Model ;(TAM). Changes in all these variables after VR exposure were analyzed.
Results: Short-term exposure to the NEIVATECH VR system only induced statistically significant changes in distance phoria (p = .016), but these changes were not clinically relevant. No significant changes were observed in VRSQ oculo-motricity and disorientation scores after exposure (p = .197 and .317, respectively). TAM scores showed a good acceptance of the system in terms of perceived enjoyment and perceived ease of use, although some concerns were raised in relation to the intention-to-use domain.
Conclusion: Exposure to the NEIVATECH VR system does not seem to adversely affect the visual function in healthy adults and its safety and acceptance profile seems to be adequate for supporting its potential use in other populations, such as amblyopic patients.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.