HM_ADET:基于摄影图像的眼睑肿瘤自动检测混合模型。

IF 2.9 4区 医学 Q3 ENGINEERING, BIOMEDICAL
Jiewei Jiang, Haiyang Liu, Lang He, Mengjie Pei, Tongtong Lin, Hailong Yang, Junhua Yang, Jiamin Gong, Xumeng Wei, Mingmin Zhu, Guohai Wu, Zhongwen Li
{"title":"HM_ADET:基于摄影图像的眼睑肿瘤自动检测混合模型。","authors":"Jiewei Jiang, Haiyang Liu, Lang He, Mengjie Pei, Tongtong Lin, Hailong Yang, Junhua Yang, Jiamin Gong, Xumeng Wei, Mingmin Zhu, Guohai Wu, Zhongwen Li","doi":"10.1186/s12938-024-01221-3","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The accurate detection of eyelid tumors is essential for effective treatment, but it can be challenging due to small and unevenly distributed lesions surrounded by irrelevant noise. Moreover, early symptoms of eyelid tumors are atypical, and some categories of eyelid tumors exhibit similar color and texture features, making it difficult to distinguish between benign and malignant eyelid tumors, particularly for ophthalmologists with limited clinical experience.</p><p><strong>Methods: </strong>We propose a hybrid model, HM_ADET, for automatic detection of eyelid tumors, including YOLOv7_CNFG to locate eyelid tumors and vision transformer (ViT) to classify benign and malignant eyelid tumors. First, the ConvNeXt module with an inverted bottleneck layer in the backbone of YOLOv7_CNFG is employed to prevent information loss of small eyelid tumors. Then, the flexible rectified linear unit (FReLU) is applied to capture multi-scale features such as texture, edge, and shape, thereby improving the localization accuracy of eyelid tumors. In addition, considering the geometric center and area difference between the predicted box (PB) and the ground truth box (GT), the GIoU_loss was utilized to handle cases of eyelid tumors with varying shapes and irregular boundaries. Finally, the multi-head attention (MHA) module is applied in ViT to extract discriminative features of eyelid tumors for benign and malignant classification.</p><p><strong>Results: </strong>Experimental results demonstrate that the HM_ADET model achieves excellent performance in the detection of eyelid tumors. In specific, YOLOv7_CNFG outperforms YOLOv7, with AP increasing from 0.763 to 0.893 on the internal test set and from 0.647 to 0.765 on the external test set. ViT achieves AUCs of 0.945 (95% CI 0.894-0.981) and 0.915 (95% CI 0.860-0.955) for the classification of benign and malignant tumors on the internal and external test sets, respectively.</p><p><strong>Conclusions: </strong>Our study provides a promising strategy for the automatic diagnosis of eyelid tumors, which could potentially improve patient outcomes and reduce healthcare costs.</p>","PeriodicalId":8927,"journal":{"name":"BioMedical Engineering OnLine","volume":"23 1","pages":"25"},"PeriodicalIF":2.9000,"publicationDate":"2024-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10903075/pdf/","citationCount":"0","resultStr":"{\"title\":\"HM_ADET: a hybrid model for automatic detection of eyelid tumors based on photographic images.\",\"authors\":\"Jiewei Jiang, Haiyang Liu, Lang He, Mengjie Pei, Tongtong Lin, Hailong Yang, Junhua Yang, Jiamin Gong, Xumeng Wei, Mingmin Zhu, Guohai Wu, Zhongwen Li\",\"doi\":\"10.1186/s12938-024-01221-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>The accurate detection of eyelid tumors is essential for effective treatment, but it can be challenging due to small and unevenly distributed lesions surrounded by irrelevant noise. Moreover, early symptoms of eyelid tumors are atypical, and some categories of eyelid tumors exhibit similar color and texture features, making it difficult to distinguish between benign and malignant eyelid tumors, particularly for ophthalmologists with limited clinical experience.</p><p><strong>Methods: </strong>We propose a hybrid model, HM_ADET, for automatic detection of eyelid tumors, including YOLOv7_CNFG to locate eyelid tumors and vision transformer (ViT) to classify benign and malignant eyelid tumors. First, the ConvNeXt module with an inverted bottleneck layer in the backbone of YOLOv7_CNFG is employed to prevent information loss of small eyelid tumors. Then, the flexible rectified linear unit (FReLU) is applied to capture multi-scale features such as texture, edge, and shape, thereby improving the localization accuracy of eyelid tumors. In addition, considering the geometric center and area difference between the predicted box (PB) and the ground truth box (GT), the GIoU_loss was utilized to handle cases of eyelid tumors with varying shapes and irregular boundaries. Finally, the multi-head attention (MHA) module is applied in ViT to extract discriminative features of eyelid tumors for benign and malignant classification.</p><p><strong>Results: </strong>Experimental results demonstrate that the HM_ADET model achieves excellent performance in the detection of eyelid tumors. In specific, YOLOv7_CNFG outperforms YOLOv7, with AP increasing from 0.763 to 0.893 on the internal test set and from 0.647 to 0.765 on the external test set. ViT achieves AUCs of 0.945 (95% CI 0.894-0.981) and 0.915 (95% CI 0.860-0.955) for the classification of benign and malignant tumors on the internal and external test sets, respectively.</p><p><strong>Conclusions: </strong>Our study provides a promising strategy for the automatic diagnosis of eyelid tumors, which could potentially improve patient outcomes and reduce healthcare costs.</p>\",\"PeriodicalId\":8927,\"journal\":{\"name\":\"BioMedical Engineering OnLine\",\"volume\":\"23 1\",\"pages\":\"25\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10903075/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"BioMedical Engineering OnLine\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1186/s12938-024-01221-3\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"BioMedical Engineering OnLine","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1186/s12938-024-01221-3","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:眼睑肿瘤的准确检测对有效治疗至关重要,但由于病灶较小且分布不均,周围还有无关的噪音,因此检测难度很大。此外,眼睑肿瘤的早期症状不典型,某些类别的眼睑肿瘤表现出相似的颜色和纹理特征,这使得眼睑肿瘤的良性和恶性难以区分,尤其是对于临床经验有限的眼科医生来说:方法:我们提出了一种用于眼睑肿瘤自动检测的混合模型 HM_ADET,其中包括用于定位眼睑肿瘤的 YOLOv7_CNFG,以及用于良性和恶性眼睑肿瘤分类的视觉转换器(ViT)。首先,在 YOLOv7_CNFG 的骨干上采用了带有倒置瓶颈层的 ConvNeXt 模块,以防止眼睑小肿瘤的信息丢失。然后,应用柔性整流线性单元(FReLU)捕捉纹理、边缘和形状等多尺度特征,从而提高眼睑肿瘤的定位精度。此外,考虑到预测框(PB)和地面实况框(GT)之间的几何中心和面积差异,GIoU_loss 被用来处理形状各异、边界不规则的眼睑肿瘤。最后,在 ViT 中应用了多头注意力(MHA)模块,以提取眼睑肿瘤的鉴别特征,进行良性和恶性分类:实验结果表明,HM_ADET 模型在眼睑肿瘤的检测中表现出色。具体来说,YOLOv7_CNFG 的表现优于 YOLOv7,在内部测试集上,AP 从 0.763 提高到 0.893,在外部测试集上,AP 从 0.647 提高到 0.765。在内部测试集和外部测试集上,ViT 对良性肿瘤和恶性肿瘤分类的 AUC 分别为 0.945(95% CI 0.894-0.981)和 0.915(95% CI 0.860-0.955):我们的研究为眼睑肿瘤的自动诊断提供了一种前景广阔的策略,有可能改善患者的预后并降低医疗成本。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
HM_ADET: a hybrid model for automatic detection of eyelid tumors based on photographic images.

Background: The accurate detection of eyelid tumors is essential for effective treatment, but it can be challenging due to small and unevenly distributed lesions surrounded by irrelevant noise. Moreover, early symptoms of eyelid tumors are atypical, and some categories of eyelid tumors exhibit similar color and texture features, making it difficult to distinguish between benign and malignant eyelid tumors, particularly for ophthalmologists with limited clinical experience.

Methods: We propose a hybrid model, HM_ADET, for automatic detection of eyelid tumors, including YOLOv7_CNFG to locate eyelid tumors and vision transformer (ViT) to classify benign and malignant eyelid tumors. First, the ConvNeXt module with an inverted bottleneck layer in the backbone of YOLOv7_CNFG is employed to prevent information loss of small eyelid tumors. Then, the flexible rectified linear unit (FReLU) is applied to capture multi-scale features such as texture, edge, and shape, thereby improving the localization accuracy of eyelid tumors. In addition, considering the geometric center and area difference between the predicted box (PB) and the ground truth box (GT), the GIoU_loss was utilized to handle cases of eyelid tumors with varying shapes and irregular boundaries. Finally, the multi-head attention (MHA) module is applied in ViT to extract discriminative features of eyelid tumors for benign and malignant classification.

Results: Experimental results demonstrate that the HM_ADET model achieves excellent performance in the detection of eyelid tumors. In specific, YOLOv7_CNFG outperforms YOLOv7, with AP increasing from 0.763 to 0.893 on the internal test set and from 0.647 to 0.765 on the external test set. ViT achieves AUCs of 0.945 (95% CI 0.894-0.981) and 0.915 (95% CI 0.860-0.955) for the classification of benign and malignant tumors on the internal and external test sets, respectively.

Conclusions: Our study provides a promising strategy for the automatic diagnosis of eyelid tumors, which could potentially improve patient outcomes and reduce healthcare costs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
BioMedical Engineering OnLine
BioMedical Engineering OnLine 工程技术-工程:生物医学
CiteScore
6.70
自引率
2.60%
发文量
79
审稿时长
1 months
期刊介绍: BioMedical Engineering OnLine is an open access, peer-reviewed journal that is dedicated to publishing research in all areas of biomedical engineering. BioMedical Engineering OnLine is aimed at readers and authors throughout the world, with an interest in using tools of the physical and data sciences and techniques in engineering to understand and solve problems in the biological and medical sciences. Topical areas include, but are not limited to: Bioinformatics- Bioinstrumentation- Biomechanics- Biomedical Devices & Instrumentation- Biomedical Signal Processing- Healthcare Information Systems- Human Dynamics- Neural Engineering- Rehabilitation Engineering- Biomaterials- Biomedical Imaging & Image Processing- BioMEMS and On-Chip Devices- Bio-Micro/Nano Technologies- Biomolecular Engineering- Biosensors- Cardiovascular Systems Engineering- Cellular Engineering- Clinical Engineering- Computational Biology- Drug Delivery Technologies- Modeling Methodologies- Nanomaterials and Nanotechnology in Biomedicine- Respiratory Systems Engineering- Robotics in Medicine- Systems and Synthetic Biology- Systems Biology- Telemedicine/Smartphone Applications in Medicine- Therapeutic Systems, Devices and Technologies- Tissue Engineering
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信