使用多功能像差仪/相干干涉仪/造影仪和两台红外瞳孔计测量瞳孔大小。

IF 2.6 3区 医学 Q2 OPHTHALMOLOGY
Petra Davidova, Marvin Biller, Vanessa Ademmer, Thomas Kohnen
{"title":"使用多功能像差仪/相干干涉仪/造影仪和两台红外瞳孔计测量瞳孔大小。","authors":"Petra Davidova, Marvin Biller, Vanessa Ademmer, Thomas Kohnen","doi":"10.1097/j.jcrs.0000000000001432","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare precision of pupil size measurements of a multifunctional device (Pentacam AXL Wave [Pentacam]) and 2 infrared-based pupillometers (PupilX, Colvard) and to compare repeatability of Pentacam and PupilX.</p><p><strong>Setting: </strong>Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany.</p><p><strong>Design: </strong>Prospective, comparative trial.</p><p><strong>Methods: </strong>Pupil diameter of healthy eyes was measured with Colvard once and Pentacam without glare (WO) and with glare (WG), PupilX in 0, 1, and 16 lux 3 times each. In a second series, measurements with Pentacam WO and PupilX in 0.06 and 0.12 lux were assessed.</p><p><strong>Results: </strong>36 eyes of participants aged 21 to 63 years were included. Mean pupil diameter was 6.05 mm with Colvard, 5.79 mm (first series), 5.50 mm (second series) with Pentacam WO, 3.42 mm WG, 7.26 mm PupilX in 0, 4.67 mm 1, 3.66 mm 16, 6.82 mm in 0.06, and 6.39 mm in 0.12 lux. Measurements with Pentacam WO were significantly different to PupilX in 0, 0.06, 0.12, and 1 lux (all P < .001), but not to Colvard ( P = .086). Pupil size measured with Pentacam WG and PupilX in 16 lux was not significantly different ( P = .647). Consecutive measurements with Pentacam WO and WG had mean SD of 0.23 mm and 0.20 mm, respectively, and with PupilX 0.11 in 0, 0.24 mm 1, and 0.20 mm in 16 lux.</p><p><strong>Conclusions: </strong>Pentacam provided good assessment of pupil size but was not equivalent to PupilX in low lighting conditions. Repeatability was more favorable for Pentacam.</p>","PeriodicalId":15214,"journal":{"name":"Journal of cataract and refractive surgery","volume":" ","pages":"631-636"},"PeriodicalIF":2.6000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11146177/pdf/","citationCount":"0","resultStr":"{\"title\":\"Pupil size measurements with a multifunctional aberrometer/coherence interferometer/tomographer and two infrared-based pupillometers.\",\"authors\":\"Petra Davidova, Marvin Biller, Vanessa Ademmer, Thomas Kohnen\",\"doi\":\"10.1097/j.jcrs.0000000000001432\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To compare precision of pupil size measurements of a multifunctional device (Pentacam AXL Wave [Pentacam]) and 2 infrared-based pupillometers (PupilX, Colvard) and to compare repeatability of Pentacam and PupilX.</p><p><strong>Setting: </strong>Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany.</p><p><strong>Design: </strong>Prospective, comparative trial.</p><p><strong>Methods: </strong>Pupil diameter of healthy eyes was measured with Colvard once and Pentacam without glare (WO) and with glare (WG), PupilX in 0, 1, and 16 lux 3 times each. In a second series, measurements with Pentacam WO and PupilX in 0.06 and 0.12 lux were assessed.</p><p><strong>Results: </strong>36 eyes of participants aged 21 to 63 years were included. Mean pupil diameter was 6.05 mm with Colvard, 5.79 mm (first series), 5.50 mm (second series) with Pentacam WO, 3.42 mm WG, 7.26 mm PupilX in 0, 4.67 mm 1, 3.66 mm 16, 6.82 mm in 0.06, and 6.39 mm in 0.12 lux. Measurements with Pentacam WO were significantly different to PupilX in 0, 0.06, 0.12, and 1 lux (all P < .001), but not to Colvard ( P = .086). Pupil size measured with Pentacam WG and PupilX in 16 lux was not significantly different ( P = .647). Consecutive measurements with Pentacam WO and WG had mean SD of 0.23 mm and 0.20 mm, respectively, and with PupilX 0.11 in 0, 0.24 mm 1, and 0.20 mm in 16 lux.</p><p><strong>Conclusions: </strong>Pentacam provided good assessment of pupil size but was not equivalent to PupilX in low lighting conditions. Repeatability was more favorable for Pentacam.</p>\",\"PeriodicalId\":15214,\"journal\":{\"name\":\"Journal of cataract and refractive surgery\",\"volume\":\" \",\"pages\":\"631-636\"},\"PeriodicalIF\":2.6000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11146177/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of cataract and refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/j.jcrs.0000000000001432\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of cataract and refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/j.jcrs.0000000000001432","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:比较一种多功能设备(Pentacam AXL Wave (OCULUS; 简称 Pentacam))和两种基于红外线的瞳孔计(PupilX (Albomed), Colvard (Oasis medical))的瞳孔大小测量精度,并比较 Pentacam 和 PupilX 的重复性:地点:德国法兰克福歌德大学眼科系:设计:前瞻性比较试验:健康眼睛的瞳孔直径用 Colvard 测量一次,Pentacam 在无眩光(WO)和有眩光(WG)的情况下测量一次,PupilX 在 0、1 和 16 勒克斯的情况下测量三次。第二轮测量使用 Pentacam WO 和 PupilX,分别在 0.06 和 0.12 勒克斯下进行:结果:共纳入 36 只眼睛,参与者年龄在 21-63 岁之间。使用 Colvard 测量的平均瞳孔直径为 6.05 毫米,使用 Pentacam WO 测量的平均瞳孔直径为 5.79 毫米(第一系列)、5.50 毫米(第二系列),使用 WG 测量的平均瞳孔直径为 3.42 毫米,使用 PupilX 测量的平均瞳孔直径为 7.26 毫米(0 勒克斯)、4.67 毫米(1 勒克斯)、3.66 毫米(16 勒克斯)、6.82 毫米(0.06 勒克斯)和 6.39 毫米(0.12 勒克斯)。在 0、0.06、0.12 和 1 lux 时,Pentacam WO 的测量值与 PupilX 的测量值有显著差异(均为 p 结论:Pentacam 可以很好地评估瞳孔大小,但在低照度条件下与 PupilX 并不相称。Pentacam 的重复性更好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Pupil size measurements with a multifunctional aberrometer/coherence interferometer/tomographer and two infrared-based pupillometers.

Purpose: To compare precision of pupil size measurements of a multifunctional device (Pentacam AXL Wave [Pentacam]) and 2 infrared-based pupillometers (PupilX, Colvard) and to compare repeatability of Pentacam and PupilX.

Setting: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany.

Design: Prospective, comparative trial.

Methods: Pupil diameter of healthy eyes was measured with Colvard once and Pentacam without glare (WO) and with glare (WG), PupilX in 0, 1, and 16 lux 3 times each. In a second series, measurements with Pentacam WO and PupilX in 0.06 and 0.12 lux were assessed.

Results: 36 eyes of participants aged 21 to 63 years were included. Mean pupil diameter was 6.05 mm with Colvard, 5.79 mm (first series), 5.50 mm (second series) with Pentacam WO, 3.42 mm WG, 7.26 mm PupilX in 0, 4.67 mm 1, 3.66 mm 16, 6.82 mm in 0.06, and 6.39 mm in 0.12 lux. Measurements with Pentacam WO were significantly different to PupilX in 0, 0.06, 0.12, and 1 lux (all P < .001), but not to Colvard ( P = .086). Pupil size measured with Pentacam WG and PupilX in 16 lux was not significantly different ( P = .647). Consecutive measurements with Pentacam WO and WG had mean SD of 0.23 mm and 0.20 mm, respectively, and with PupilX 0.11 in 0, 0.24 mm 1, and 0.20 mm in 16 lux.

Conclusions: Pentacam provided good assessment of pupil size but was not equivalent to PupilX in low lighting conditions. Repeatability was more favorable for Pentacam.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.60
自引率
14.30%
发文量
259
审稿时长
8.5 weeks
期刊介绍: The Journal of Cataract & Refractive Surgery (JCRS), a preeminent peer-reviewed monthly ophthalmology publication, is the official journal of the American Society of Cataract and Refractive Surgery (ASCRS) and the European Society of Cataract and Refractive Surgeons (ESCRS). JCRS publishes high quality articles on all aspects of anterior segment surgery. In addition to original clinical studies, the journal features a consultation section, practical techniques, important cases, and reviews as well as basic science articles.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信