计算机辅助设计和计算机辅助制造固定卡环与传统固定卡环的元素组成、耐腐蚀性和机械性能比较

IF 1.9 4区 医学 Q2 DENTISTRY, ORAL SURGERY & MEDICINE
Yasuhiro Namura, Helen Pullisaar, Heidi Vanessa Holm, Morten Syverud, Aida Mulic, Vaska Vandevska-Radunovic
{"title":"计算机辅助设计和计算机辅助制造固定卡环与传统固定卡环的元素组成、耐腐蚀性和机械性能比较","authors":"Yasuhiro Namura, Helen Pullisaar, Heidi Vanessa Holm, Morten Syverud, Aida Mulic, Vaska Vandevska-Radunovic","doi":"10.2334/josnusd.23-0303","DOIUrl":null,"url":null,"abstract":"</p><p><b>Purpose:</b> To investigate the elemental composition, corrosion resistance, and mechanical properties of computer-aided design and computer-aided manufacturing (CAD-CAM) retainers versus conventional fixed retainers (FRs).</p><p><b>Methods:</b> Eight different retainer wires were investigated. Energy dispersive X-ray spectroscopy was used to determine the elemental composition. Leakage was analysed according to ISO 10271:2020 guidelines. Hardness was tested using the Vickers method with a load of 0.3 kg. The tensile force and tensile strength were evaluated. Multiple comparisons among wires of hardness, tensile force, and strength were conducted using the Welch <i>t</i>-test, with Bonferroni correction.</p><p><b>Results:</b> Nickel was present in all wires. The CAD-CAM-FR wire, which contained more nickel than the other wires, had no measurable leakage. The gold-plated wires had the highest total leakage, but did not exceed the ISO standard limit. The hardness of the stainless-steel twisted wires was the highest and that of the CAD-CAM-FR wire was the lowest. The tensile strength of the CAD-CAM-FR wire was significantly lower than that of the other wires and similar to the other twisted-wire retainers.</p><p><b>Conclusion:</b> The CAD-CAM-FR wire is likely to have high corrosion resistance and flexibility due to its low hardness.</p>\n<p></p>","PeriodicalId":16646,"journal":{"name":"Journal of oral science","volume":null,"pages":null},"PeriodicalIF":1.9000,"publicationDate":"2024-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Elemental composition, corrosion resistance and mechanical properties of computer-aided design and computer-aided manufacturing fixed retainers versus conventional fixed retainers\",\"authors\":\"Yasuhiro Namura, Helen Pullisaar, Heidi Vanessa Holm, Morten Syverud, Aida Mulic, Vaska Vandevska-Radunovic\",\"doi\":\"10.2334/josnusd.23-0303\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"</p><p><b>Purpose:</b> To investigate the elemental composition, corrosion resistance, and mechanical properties of computer-aided design and computer-aided manufacturing (CAD-CAM) retainers versus conventional fixed retainers (FRs).</p><p><b>Methods:</b> Eight different retainer wires were investigated. Energy dispersive X-ray spectroscopy was used to determine the elemental composition. Leakage was analysed according to ISO 10271:2020 guidelines. Hardness was tested using the Vickers method with a load of 0.3 kg. The tensile force and tensile strength were evaluated. Multiple comparisons among wires of hardness, tensile force, and strength were conducted using the Welch <i>t</i>-test, with Bonferroni correction.</p><p><b>Results:</b> Nickel was present in all wires. The CAD-CAM-FR wire, which contained more nickel than the other wires, had no measurable leakage. The gold-plated wires had the highest total leakage, but did not exceed the ISO standard limit. The hardness of the stainless-steel twisted wires was the highest and that of the CAD-CAM-FR wire was the lowest. The tensile strength of the CAD-CAM-FR wire was significantly lower than that of the other wires and similar to the other twisted-wire retainers.</p><p><b>Conclusion:</b> The CAD-CAM-FR wire is likely to have high corrosion resistance and flexibility due to its low hardness.</p>\\n<p></p>\",\"PeriodicalId\":16646,\"journal\":{\"name\":\"Journal of oral science\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-02-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of oral science\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.2334/josnusd.23-0303\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of oral science","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2334/josnusd.23-0303","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:研究计算机辅助设计和计算机辅助制造(CAD-CAM)保持器与传统固定保持器(FR)的元素组成、耐腐蚀性和机械性能:方法:研究了八种不同的固位体钢丝。采用能量色散 X 射线光谱法确定元素组成。根据 ISO 10271:2020 指南对渗漏进行分析。硬度测试采用维氏方法,载荷为 0.3 千克。对拉力和拉伸强度进行了评估。采用韦尔奇 t 检验法对钢丝的硬度、拉力和强度进行多重比较,并进行 Bonferroni 校正:所有钢丝中都含有镍。CAD-CAM-FR 焊丝比其他焊丝含更多的镍,但没有明显的渗漏。镀金金属丝的总泄漏量最高,但未超过 ISO 标准限值。不锈钢绞线的硬度最高,CAD-CAM-FR 线的硬度最低。CAD-CAM-FR 金属丝的抗拉强度明显低于其他金属丝,与其他扭转金属丝保持器相似:结论:CAD-CAM-FR 金属丝的硬度较低,因此可能具有较高的耐腐蚀性和柔韧性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Elemental composition, corrosion resistance and mechanical properties of computer-aided design and computer-aided manufacturing fixed retainers versus conventional fixed retainers

Purpose: To investigate the elemental composition, corrosion resistance, and mechanical properties of computer-aided design and computer-aided manufacturing (CAD-CAM) retainers versus conventional fixed retainers (FRs).

Methods: Eight different retainer wires were investigated. Energy dispersive X-ray spectroscopy was used to determine the elemental composition. Leakage was analysed according to ISO 10271:2020 guidelines. Hardness was tested using the Vickers method with a load of 0.3 kg. The tensile force and tensile strength were evaluated. Multiple comparisons among wires of hardness, tensile force, and strength were conducted using the Welch t-test, with Bonferroni correction.

Results: Nickel was present in all wires. The CAD-CAM-FR wire, which contained more nickel than the other wires, had no measurable leakage. The gold-plated wires had the highest total leakage, but did not exceed the ISO standard limit. The hardness of the stainless-steel twisted wires was the highest and that of the CAD-CAM-FR wire was the lowest. The tensile strength of the CAD-CAM-FR wire was significantly lower than that of the other wires and similar to the other twisted-wire retainers.

Conclusion: The CAD-CAM-FR wire is likely to have high corrosion resistance and flexibility due to its low hardness.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of oral science
Journal of oral science DENTISTRY, ORAL SURGERY & MEDICINE-MATERIALS SCIENCE, BIOMATERIALS
CiteScore
3.80
自引率
0.00%
发文量
58
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信