Weiqing Ji;Xingzhuo Guo;Shouan Pan;Fei Long;Tsung-Yi Ho;Ulf Schlichtmann;Hailong Yao
{"title":"基于 GNN 的浓度预测与微流控混合器的可变输入流量。","authors":"Weiqing Ji;Xingzhuo Guo;Shouan Pan;Fei Long;Tsung-Yi Ho;Ulf Schlichtmann;Hailong Yao","doi":"10.1109/TBCAS.2024.3366691","DOIUrl":null,"url":null,"abstract":"Recent years have witnessed significant advances brought by microfluidic biochips in automating biochemical protocols. Accurate preparation of fluid samples is an essential component of these protocols, where concentration prediction and generation are critical. Equipped with the advantages of convenient fabrication and control, microfluidic mixers demonstrate huge potential in sample preparation. Although finite element analysis (FEA) is the most commonly used simulation method for accurate concentration prediction of a given microfluidic mixer, it is time-consuming with poor scalability for large biochip sizes. Recently, machine learning models have been adopted in concentration prediction, with great potential in enhancing the efficiency over traditional FEA methods. However, the state-of-the-art machine learning-based method can only predict the concentration of mixers with fixed input flow rates and fixed sizes. In this paper, we propose a new concentration prediction method based on graph neural networks (GNNs), which can predict output concentrations for microfluidic mixters with variable input flow rates. Moreover, a transfer learning method is proposed to transfer the trained model to mixers of different sizes with reduced training data. Experimental results show that, for microfluidic mixers with fixed input flow rates, the proposed method obtains an average reduction of 88% in terms of prediction errors compared with the state-of-the-art method. For microfluidic mixers with variable input flow rates, the proposed method reduces the prediction error by 85% on average. Besides, the proposed transfer learning method reduces the training data by 84% for extending the pre-trained model for microfluidic mixers of different sizes with acceptable prediction error.","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"18 3","pages":"622-635"},"PeriodicalIF":0.0000,"publicationDate":"2024-02-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"GNN-Based Concentration Prediction With Variable Input Flow Rates for Microfluidic Mixers\",\"authors\":\"Weiqing Ji;Xingzhuo Guo;Shouan Pan;Fei Long;Tsung-Yi Ho;Ulf Schlichtmann;Hailong Yao\",\"doi\":\"10.1109/TBCAS.2024.3366691\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Recent years have witnessed significant advances brought by microfluidic biochips in automating biochemical protocols. Accurate preparation of fluid samples is an essential component of these protocols, where concentration prediction and generation are critical. Equipped with the advantages of convenient fabrication and control, microfluidic mixers demonstrate huge potential in sample preparation. Although finite element analysis (FEA) is the most commonly used simulation method for accurate concentration prediction of a given microfluidic mixer, it is time-consuming with poor scalability for large biochip sizes. Recently, machine learning models have been adopted in concentration prediction, with great potential in enhancing the efficiency over traditional FEA methods. However, the state-of-the-art machine learning-based method can only predict the concentration of mixers with fixed input flow rates and fixed sizes. In this paper, we propose a new concentration prediction method based on graph neural networks (GNNs), which can predict output concentrations for microfluidic mixters with variable input flow rates. Moreover, a transfer learning method is proposed to transfer the trained model to mixers of different sizes with reduced training data. Experimental results show that, for microfluidic mixers with fixed input flow rates, the proposed method obtains an average reduction of 88% in terms of prediction errors compared with the state-of-the-art method. For microfluidic mixers with variable input flow rates, the proposed method reduces the prediction error by 85% on average. Besides, the proposed transfer learning method reduces the training data by 84% for extending the pre-trained model for microfluidic mixers of different sizes with acceptable prediction error.\",\"PeriodicalId\":94031,\"journal\":{\"name\":\"IEEE transactions on biomedical circuits and systems\",\"volume\":\"18 3\",\"pages\":\"622-635\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-02-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on biomedical circuits and systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10444649/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on biomedical circuits and systems","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10444649/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
GNN-Based Concentration Prediction With Variable Input Flow Rates for Microfluidic Mixers
Recent years have witnessed significant advances brought by microfluidic biochips in automating biochemical protocols. Accurate preparation of fluid samples is an essential component of these protocols, where concentration prediction and generation are critical. Equipped with the advantages of convenient fabrication and control, microfluidic mixers demonstrate huge potential in sample preparation. Although finite element analysis (FEA) is the most commonly used simulation method for accurate concentration prediction of a given microfluidic mixer, it is time-consuming with poor scalability for large biochip sizes. Recently, machine learning models have been adopted in concentration prediction, with great potential in enhancing the efficiency over traditional FEA methods. However, the state-of-the-art machine learning-based method can only predict the concentration of mixers with fixed input flow rates and fixed sizes. In this paper, we propose a new concentration prediction method based on graph neural networks (GNNs), which can predict output concentrations for microfluidic mixters with variable input flow rates. Moreover, a transfer learning method is proposed to transfer the trained model to mixers of different sizes with reduced training data. Experimental results show that, for microfluidic mixers with fixed input flow rates, the proposed method obtains an average reduction of 88% in terms of prediction errors compared with the state-of-the-art method. For microfluidic mixers with variable input flow rates, the proposed method reduces the prediction error by 85% on average. Besides, the proposed transfer learning method reduces the training data by 84% for extending the pre-trained model for microfluidic mixers of different sizes with acceptable prediction error.