Marlies Ullrich, Andreea D Fisus, Stefan Palkovits, Julius Hienert, Nino Hirnschall, Oliver Findl
{"title":"疏水性丙烯酸开环单片眼内透镜的旋转稳定性和囊袋性能。","authors":"Marlies Ullrich, Andreea D Fisus, Stefan Palkovits, Julius Hienert, Nino Hirnschall, Oliver Findl","doi":"10.1177/11206721241234393","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the rotational stability and capsular bag performance of a blue light-absorbing hydrophobic acrylic open-loop single-piece intraocular lens (IOL) with a blast-finished anchor wing haptic design during the first 6 postoperative months.</p><p><strong>Methods: </strong>In this prospective clinical study, patients with age-related cataract and potential postoperative corrected distance visual acuity (CDVA) of 0.2 logMAR or better were included. The patients received a non-toric hydrophobic acrylic single-piece IOL with an axis mark (YST0.00; Nidek Co. Ltd, Japan). Surgeries were video-taped. Retroillumination images were acquired 1 h, 1 week and 6 months postoperatively. Rotational stability was assessed by precise image overlay. At 6 months, Purkinje meter measurements were performed to evaluate tilt and decentration.</p><p><strong>Results: </strong>In total, 100 eyes of 77 patients were included in the analysis. Mean absolute rotation was 2.1 ± 1.7° (median 1.7, range: 0-7.9) at 6 months (1 h - 6 months postoperatively). IOL rotation was ≤3° and ≤6° in 74 (74%) and 98 (98%) eyes, respectively. Mean absolute IOL rotation from the end of surgery to 6 months was 2.5 ± 2.2° (median 2.3, range: 0-15.6; n = 78). Mean tilt (pupillary axis) and decentration were 4.1 ± 1.9° (median 4.0, range: 0.5-8.2) and 0.35 ± 0.17 mm (median 0.32, range: 0.06-0.91) respectively (n = 84). Postoperatively, 98 (98%) eyes achieved a CDVA of 0.2 logMAR or better, 95 (95%) of ≤0.1 and 81 (81%) of ≤0.0.</p><p><strong>Conclusions: </strong>This hydrophobic acrylic single-piece IOL showed an excellent rotational stability and capsular bag position with low tilt and decentration values.</p>","PeriodicalId":12000,"journal":{"name":"European Journal of Ophthalmology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rotational stability and capsular bag performance of a hydrophobic acrylic open-loop single-piece intraocular lens.\",\"authors\":\"Marlies Ullrich, Andreea D Fisus, Stefan Palkovits, Julius Hienert, Nino Hirnschall, Oliver Findl\",\"doi\":\"10.1177/11206721241234393\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the rotational stability and capsular bag performance of a blue light-absorbing hydrophobic acrylic open-loop single-piece intraocular lens (IOL) with a blast-finished anchor wing haptic design during the first 6 postoperative months.</p><p><strong>Methods: </strong>In this prospective clinical study, patients with age-related cataract and potential postoperative corrected distance visual acuity (CDVA) of 0.2 logMAR or better were included. The patients received a non-toric hydrophobic acrylic single-piece IOL with an axis mark (YST0.00; Nidek Co. Ltd, Japan). Surgeries were video-taped. Retroillumination images were acquired 1 h, 1 week and 6 months postoperatively. Rotational stability was assessed by precise image overlay. At 6 months, Purkinje meter measurements were performed to evaluate tilt and decentration.</p><p><strong>Results: </strong>In total, 100 eyes of 77 patients were included in the analysis. Mean absolute rotation was 2.1 ± 1.7° (median 1.7, range: 0-7.9) at 6 months (1 h - 6 months postoperatively). IOL rotation was ≤3° and ≤6° in 74 (74%) and 98 (98%) eyes, respectively. Mean absolute IOL rotation from the end of surgery to 6 months was 2.5 ± 2.2° (median 2.3, range: 0-15.6; n = 78). Mean tilt (pupillary axis) and decentration were 4.1 ± 1.9° (median 4.0, range: 0.5-8.2) and 0.35 ± 0.17 mm (median 0.32, range: 0.06-0.91) respectively (n = 84). Postoperatively, 98 (98%) eyes achieved a CDVA of 0.2 logMAR or better, 95 (95%) of ≤0.1 and 81 (81%) of ≤0.0.</p><p><strong>Conclusions: </strong>This hydrophobic acrylic single-piece IOL showed an excellent rotational stability and capsular bag position with low tilt and decentration values.</p>\",\"PeriodicalId\":12000,\"journal\":{\"name\":\"European Journal of Ophthalmology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/11206721241234393\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/11206721241234393","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/22 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Rotational stability and capsular bag performance of a hydrophobic acrylic open-loop single-piece intraocular lens.
Purpose: To evaluate the rotational stability and capsular bag performance of a blue light-absorbing hydrophobic acrylic open-loop single-piece intraocular lens (IOL) with a blast-finished anchor wing haptic design during the first 6 postoperative months.
Methods: In this prospective clinical study, patients with age-related cataract and potential postoperative corrected distance visual acuity (CDVA) of 0.2 logMAR or better were included. The patients received a non-toric hydrophobic acrylic single-piece IOL with an axis mark (YST0.00; Nidek Co. Ltd, Japan). Surgeries were video-taped. Retroillumination images were acquired 1 h, 1 week and 6 months postoperatively. Rotational stability was assessed by precise image overlay. At 6 months, Purkinje meter measurements were performed to evaluate tilt and decentration.
Results: In total, 100 eyes of 77 patients were included in the analysis. Mean absolute rotation was 2.1 ± 1.7° (median 1.7, range: 0-7.9) at 6 months (1 h - 6 months postoperatively). IOL rotation was ≤3° and ≤6° in 74 (74%) and 98 (98%) eyes, respectively. Mean absolute IOL rotation from the end of surgery to 6 months was 2.5 ± 2.2° (median 2.3, range: 0-15.6; n = 78). Mean tilt (pupillary axis) and decentration were 4.1 ± 1.9° (median 4.0, range: 0.5-8.2) and 0.35 ± 0.17 mm (median 0.32, range: 0.06-0.91) respectively (n = 84). Postoperatively, 98 (98%) eyes achieved a CDVA of 0.2 logMAR or better, 95 (95%) of ≤0.1 and 81 (81%) of ≤0.0.
Conclusions: This hydrophobic acrylic single-piece IOL showed an excellent rotational stability and capsular bag position with low tilt and decentration values.
期刊介绍:
The European Journal of Ophthalmology was founded in 1991 and is issued in print bi-monthly. It publishes only peer-reviewed original research reporting clinical observations and laboratory investigations with clinical relevance focusing on new diagnostic and surgical techniques, instrument and therapy updates, results of clinical trials and research findings.