火灾参数对弯曲隧道临界速度的影响:数值研究与响应面分析

IF 2.3 3区 工程技术 Q2 ENGINEERING, MULTIDISCIPLINARY
Saeid Jafari, Bijan Farhanieh, Hossein Afshin
{"title":"火灾参数对弯曲隧道临界速度的影响:数值研究与响应面分析","authors":"Saeid Jafari,&nbsp;Bijan Farhanieh,&nbsp;Hossein Afshin","doi":"10.1007/s10694-024-01548-2","DOIUrl":null,"url":null,"abstract":"<div><p>Fire accidents are more likely to occur in tunnels with different curves, aspect ratios, and slopes due to the land’s geographical characteristics. A three-dimensional computational fluid dynamics code with curvilinear grids fitted to the body was used to simulate a variety of fire locations releasing heat at a rate of 5 MW–60 MW in a tunnel with a turning radius of 100 m–1500 m, an aspect ratio of 0.5–2, and a slope between – 10% and 10%. Using the Design of Experiments (DOE) method coupled with numerical simulations, 32 3D numerical models were constructed and a second-order critical velocity model was generated. Analysis of critical velocity was performed based on Response Surface Methodology (RSM) and multifactor curve plots were drawn for effective parameters. The results showed that the critical velocity was proportional to one-third power of the heat release rate. It was also observed that the critical velocity increased gradually as the fire source moved from the tunnel’s center to its walls. Furthermore, the critical velocity decreased with increasing the aspect ratio. Results showed that the critical velocity increased with increasing the tunnel turning radius. Moreover, tunnels with negative slopes have a higher critical velocity than horizontal tunnels without slopes. Finally, by defining the parameters in non-dimensional form, a new modified form was derived for critical velocity calculation (R<sup>2</sup> = 0.98). A critical velocity of 1.24 m/s–5.21 m/s was calculated based on five parameter values in this study. Furthermore, other straight and curved tunnel models confirmed the formula’s predictions.</p></div>","PeriodicalId":558,"journal":{"name":"Fire Technology","volume":"60 3","pages":"1769 - 1802"},"PeriodicalIF":2.3000,"publicationDate":"2024-02-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effects of Fire Parameters on Critical Velocity in Curved Tunnels: A Numerical Study and Response Surface Analysis\",\"authors\":\"Saeid Jafari,&nbsp;Bijan Farhanieh,&nbsp;Hossein Afshin\",\"doi\":\"10.1007/s10694-024-01548-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Fire accidents are more likely to occur in tunnels with different curves, aspect ratios, and slopes due to the land’s geographical characteristics. A three-dimensional computational fluid dynamics code with curvilinear grids fitted to the body was used to simulate a variety of fire locations releasing heat at a rate of 5 MW–60 MW in a tunnel with a turning radius of 100 m–1500 m, an aspect ratio of 0.5–2, and a slope between – 10% and 10%. Using the Design of Experiments (DOE) method coupled with numerical simulations, 32 3D numerical models were constructed and a second-order critical velocity model was generated. Analysis of critical velocity was performed based on Response Surface Methodology (RSM) and multifactor curve plots were drawn for effective parameters. The results showed that the critical velocity was proportional to one-third power of the heat release rate. It was also observed that the critical velocity increased gradually as the fire source moved from the tunnel’s center to its walls. Furthermore, the critical velocity decreased with increasing the aspect ratio. Results showed that the critical velocity increased with increasing the tunnel turning radius. Moreover, tunnels with negative slopes have a higher critical velocity than horizontal tunnels without slopes. Finally, by defining the parameters in non-dimensional form, a new modified form was derived for critical velocity calculation (R<sup>2</sup> = 0.98). A critical velocity of 1.24 m/s–5.21 m/s was calculated based on five parameter values in this study. Furthermore, other straight and curved tunnel models confirmed the formula’s predictions.</p></div>\",\"PeriodicalId\":558,\"journal\":{\"name\":\"Fire Technology\",\"volume\":\"60 3\",\"pages\":\"1769 - 1802\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2024-02-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Fire Technology\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s10694-024-01548-2\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Fire Technology","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1007/s10694-024-01548-2","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

摘要

摘要 由于土地的地理特征,在具有不同曲线、长宽比和坡度的隧道中更容易发生火灾事故。研究人员使用三维计算流体动力学代码和曲面网格,模拟了在转弯半径为 100 米至 1500 米、长宽比为 0.5-2 和坡度为-10%至 10%的隧道中,以 5 兆瓦至 60 兆瓦的速度释放热量的各种起火点。利用实验设计 (DOE) 方法和数值模拟,构建了 32 个三维数值模型,并生成了二阶临界速度模型。根据响应面法(RSM)对临界速度进行了分析,并绘制了有效参数的多因素曲线图。结果表明,临界速度与热释放率的三分之一幂成正比。同时还观察到,当火源从隧道中心向隧道壁移动时,临界速度逐渐增加。此外,临界速度随着纵横比的增加而降低。结果表明,临界速度随着隧道转弯半径的增加而增加。此外,负斜坡隧道的临界速度高于无斜坡的水平隧道。最后,通过以非量纲形式定义参数,得出了一种新的临界速度计算修正形式(R2 = 0.98)。本研究根据五个参数值计算出的临界速度为 1.24 米/秒-5.21 米/秒。此外,其他直线和曲线隧道模型也证实了该公式的预测结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of Fire Parameters on Critical Velocity in Curved Tunnels: A Numerical Study and Response Surface Analysis

Fire accidents are more likely to occur in tunnels with different curves, aspect ratios, and slopes due to the land’s geographical characteristics. A three-dimensional computational fluid dynamics code with curvilinear grids fitted to the body was used to simulate a variety of fire locations releasing heat at a rate of 5 MW–60 MW in a tunnel with a turning radius of 100 m–1500 m, an aspect ratio of 0.5–2, and a slope between – 10% and 10%. Using the Design of Experiments (DOE) method coupled with numerical simulations, 32 3D numerical models were constructed and a second-order critical velocity model was generated. Analysis of critical velocity was performed based on Response Surface Methodology (RSM) and multifactor curve plots were drawn for effective parameters. The results showed that the critical velocity was proportional to one-third power of the heat release rate. It was also observed that the critical velocity increased gradually as the fire source moved from the tunnel’s center to its walls. Furthermore, the critical velocity decreased with increasing the aspect ratio. Results showed that the critical velocity increased with increasing the tunnel turning radius. Moreover, tunnels with negative slopes have a higher critical velocity than horizontal tunnels without slopes. Finally, by defining the parameters in non-dimensional form, a new modified form was derived for critical velocity calculation (R2 = 0.98). A critical velocity of 1.24 m/s–5.21 m/s was calculated based on five parameter values in this study. Furthermore, other straight and curved tunnel models confirmed the formula’s predictions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Fire Technology
Fire Technology 工程技术-材料科学:综合
CiteScore
6.60
自引率
14.70%
发文量
137
审稿时长
7.5 months
期刊介绍: Fire Technology publishes original contributions, both theoretical and empirical, that contribute to the solution of problems in fire safety science and engineering. It is the leading journal in the field, publishing applied research dealing with the full range of actual and potential fire hazards facing humans and the environment. It covers the entire domain of fire safety science and engineering problems relevant in industrial, operational, cultural, and environmental applications, including modeling, testing, detection, suppression, human behavior, wildfires, structures, and risk analysis. The aim of Fire Technology is to push forward the frontiers of knowledge and technology by encouraging interdisciplinary communication of significant technical developments in fire protection and subjects of scientific interest to the fire protection community at large. It is published in conjunction with the National Fire Protection Association (NFPA) and the Society of Fire Protection Engineers (SFPE). The mission of NFPA is to help save lives and reduce loss with information, knowledge, and passion. The mission of SFPE is advancing the science and practice of fire protection engineering internationally.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信