奥姆斯特德县非感染性心血管植入式电子设备并发症 30 年的发展趋势

IF 2.5 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Gurukripa N. Kowlgi MBBS, MS , Vaibhav Vaidya MBBS , Ming-Yan Dai MD , Pragyat Futela MBBS , Rahul Mishra MBBS , David O. Hodge , Abhishek J. Deshmukh MBBS , Siva K. Mulpuru MD, MPH , Paul A. Friedman MD , Yong-Mei Cha MD
{"title":"奥姆斯特德县非感染性心血管植入式电子设备并发症 30 年的发展趋势","authors":"Gurukripa N. Kowlgi MBBS, MS ,&nbsp;Vaibhav Vaidya MBBS ,&nbsp;Ming-Yan Dai MD ,&nbsp;Pragyat Futela MBBS ,&nbsp;Rahul Mishra MBBS ,&nbsp;David O. Hodge ,&nbsp;Abhishek J. Deshmukh MBBS ,&nbsp;Siva K. Mulpuru MD, MPH ,&nbsp;Paul A. Friedman MD ,&nbsp;Yong-Mei Cha MD","doi":"10.1016/j.hroo.2024.02.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Cardiac implantable electronic devices (CIEDs), such as permanent pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy devices, alleviate morbidity and mortality in various diseases. There is a paucity of real-world data on CIED complications and trends.</p></div><div><h3>Objectives</h3><p>We sought to describe trends in noninfectious CIED complications over the past 3 decades in Olmsted County.</p></div><div><h3>Methods</h3><p>The Rochester Epidemiology Project is a medical records linkage system comprising records of over 500,000 residents of Olmsted County from 1966 to present. CIED implantations between 1988 and 2018 were determined. Trends in noninfectious complications within 30 days of implantation were analyzed.</p></div><div><h3>Results</h3><p>A total of 157 (6.2%) of 2536 patients who received CIED experienced device complications. A total of 2.7% of the implants had major complications requiring intervention. Lead dislodgement was the most common (2.8%), followed by hematoma (1.7%). Complications went up from 1988 to 2005, and then showed a downtrend until 2018, driven by a decline in hematomas in the last decade (<em>P &lt;</em> .01). Those with complications were more likely to have prosthetic valves. Obesity appeared to have a protective effect in a multivariate regression model. The mean Charlson comorbidity index has trended up over the 30 years.</p></div><div><h3>Conclusion</h3><p>Our study describes a real-world trend of CIED complications over 3 decades. Lead dislodgements and hematomas were the most common complications. Complications have declined over the last decade due to safer practices and a better understanding of anticoagulant management.</p></div>","PeriodicalId":29772,"journal":{"name":"Heart Rhythm O2","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2024-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S2666501824000278/pdfft?md5=e019c70923c849885f3a1c4dce6181f2&pid=1-s2.0-S2666501824000278-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Trends in the 30-year span of noninfectious cardiovascular implantable electronic device complications in Olmsted County\",\"authors\":\"Gurukripa N. Kowlgi MBBS, MS ,&nbsp;Vaibhav Vaidya MBBS ,&nbsp;Ming-Yan Dai MD ,&nbsp;Pragyat Futela MBBS ,&nbsp;Rahul Mishra MBBS ,&nbsp;David O. Hodge ,&nbsp;Abhishek J. Deshmukh MBBS ,&nbsp;Siva K. Mulpuru MD, MPH ,&nbsp;Paul A. Friedman MD ,&nbsp;Yong-Mei Cha MD\",\"doi\":\"10.1016/j.hroo.2024.02.001\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Cardiac implantable electronic devices (CIEDs), such as permanent pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy devices, alleviate morbidity and mortality in various diseases. There is a paucity of real-world data on CIED complications and trends.</p></div><div><h3>Objectives</h3><p>We sought to describe trends in noninfectious CIED complications over the past 3 decades in Olmsted County.</p></div><div><h3>Methods</h3><p>The Rochester Epidemiology Project is a medical records linkage system comprising records of over 500,000 residents of Olmsted County from 1966 to present. CIED implantations between 1988 and 2018 were determined. Trends in noninfectious complications within 30 days of implantation were analyzed.</p></div><div><h3>Results</h3><p>A total of 157 (6.2%) of 2536 patients who received CIED experienced device complications. A total of 2.7% of the implants had major complications requiring intervention. Lead dislodgement was the most common (2.8%), followed by hematoma (1.7%). Complications went up from 1988 to 2005, and then showed a downtrend until 2018, driven by a decline in hematomas in the last decade (<em>P &lt;</em> .01). Those with complications were more likely to have prosthetic valves. Obesity appeared to have a protective effect in a multivariate regression model. The mean Charlson comorbidity index has trended up over the 30 years.</p></div><div><h3>Conclusion</h3><p>Our study describes a real-world trend of CIED complications over 3 decades. Lead dislodgements and hematomas were the most common complications. Complications have declined over the last decade due to safer practices and a better understanding of anticoagulant management.</p></div>\",\"PeriodicalId\":29772,\"journal\":{\"name\":\"Heart Rhythm O2\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2024-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S2666501824000278/pdfft?md5=e019c70923c849885f3a1c4dce6181f2&pid=1-s2.0-S2666501824000278-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Heart Rhythm O2\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2666501824000278\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Heart Rhythm O2","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2666501824000278","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景心脏植入式电子装置(CIED),如永久性心脏起搏器、植入式心律转复除颤器和心脏再同步治疗装置,可减轻各种疾病的发病率和死亡率。罗切斯特流行病学项目是一个医疗记录链接系统,包含 1966 年至今奥姆斯特德县 50 多万居民的记录。确定了 1988 年至 2018 年期间的 CIED 植入情况。结果 在 2536 名接受 CIED 的患者中,共有 157 人(6.2%)出现了设备并发症。共有2.7%的植入者出现了需要干预的重大并发症。最常见的是导线脱落(2.8%),其次是血肿(1.7%)。从1988年到2005年,并发症呈上升趋势,直到2018年,并发症呈下降趋势,其原因是血肿在过去十年中有所下降(P <.01)。出现并发症的患者更有可能使用人工瓣膜。在多变量回归模型中,肥胖似乎具有保护作用。我们的研究描述了30年来CIED并发症的真实世界趋势。引线脱落和血肿是最常见的并发症。由于采用了更安全的操作方法以及对抗凝剂管理有了更好的了解,过去十年来并发症有所减少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Trends in the 30-year span of noninfectious cardiovascular implantable electronic device complications in Olmsted County

Background

Cardiac implantable electronic devices (CIEDs), such as permanent pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization therapy devices, alleviate morbidity and mortality in various diseases. There is a paucity of real-world data on CIED complications and trends.

Objectives

We sought to describe trends in noninfectious CIED complications over the past 3 decades in Olmsted County.

Methods

The Rochester Epidemiology Project is a medical records linkage system comprising records of over 500,000 residents of Olmsted County from 1966 to present. CIED implantations between 1988 and 2018 were determined. Trends in noninfectious complications within 30 days of implantation were analyzed.

Results

A total of 157 (6.2%) of 2536 patients who received CIED experienced device complications. A total of 2.7% of the implants had major complications requiring intervention. Lead dislodgement was the most common (2.8%), followed by hematoma (1.7%). Complications went up from 1988 to 2005, and then showed a downtrend until 2018, driven by a decline in hematomas in the last decade (P < .01). Those with complications were more likely to have prosthetic valves. Obesity appeared to have a protective effect in a multivariate regression model. The mean Charlson comorbidity index has trended up over the 30 years.

Conclusion

Our study describes a real-world trend of CIED complications over 3 decades. Lead dislodgements and hematomas were the most common complications. Complications have declined over the last decade due to safer practices and a better understanding of anticoagulant management.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Heart Rhythm O2
Heart Rhythm O2 Cardiology and Cardiovascular Medicine
CiteScore
3.30
自引率
0.00%
发文量
0
审稿时长
52 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信